文献速递消化内镜

新型人工智能系统评估肠道准备质量

A novel artificial intelligence system for the assessment of bowel preparation (with video).
PubMed 文献 · Gastrointest Endosc · 2019-11-26

本研究利用深度卷积神经网络开发了名为ENDOANGEL的人工智能系统,用于客观评估结肠镜检查的肠道准备质量。该系统在120张图像的人机竞赛中达到93.33%的准确率,优于所有内镜医师;在20个结肠镜视频中准确率为89.04%,并能每30秒提供BBPS评分并显示撤镜阶段各评分帧的累积比例。

要点

  • ENDOANGEL在120张图像人机竞赛中准确率93.33%,优于所有内镜医师。
  • 在100张含气泡图像中准确率为80.00%,在20个视频中准确率为89.04%。
  • 系统每30秒提供BBPS评分并显示撤镜阶段各评分帧的累积比例。

核心结论

  • ENDOANGEL提供了一种新型、更准确的肠道准备评估方法,可作为客观稳定的系统可靠应用于临床。

研究设计与样本

  • 回顾性收集结肠镜图像训练深度卷积神经网络,通过人机竞赛比较性能,并应用于结肠镜视频开发ENDOANGEL系统。

主要发现

  • ENDOANGEL在120张图像的人机竞赛中准确率达93.33%,优于所有内镜医师。
  • ENDOANGEL在100张含气泡图像中准确率达80.00%。
  • 在20个结肠镜视频中准确率为89.04%,并能每30秒提示BBPS评分并显示撤镜阶段各评分帧的累积百分比。

临床怎么用

  • ENDOANGEL可每30秒提供BBPS评分并显示撤镜阶段各评分帧的累积比例,辅助内镜医师客观评估肠道准备。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: The quality of bowel preparation is an important factor that can affect the effectiveness of a colonoscopy. Several tools, such as the Boston Bowel Preparation Scale (BBPS) and Ottawa Bowel Preparation Scale, have been developed to evaluate bowel preparation. However, understanding the differences between evaluation methods and consistently applying them can be challenging for endoscopists. There are also subjective biases and differences among endoscopists. Therefore, this study aimed to develop a novel, objective, and stable method for the assessment of bowel preparation through artificial intelligence. METHODS: We used a deep convolutional neural network to develop this novel system. First, we retrospectively collected colonoscopy images to train the system and then compared its performance with endoscopists via a human-machine contest. Then, we applied this model to colonoscopy videos and developed a system named ENDOANGEL to provide bowel preparation scores every 30 seconds and to show the cumulative ratio of frames for each score during the withdrawal phase of the colonoscopy. RESULTS: ENDOANGEL achieved 93.33% accuracy in the human-machine contest with 120 images, which was better than that of all endoscopists. Moreover, ENDOANGEL achieved 80.00% accuracy among 100 images with bubbles. In 20 colonoscopy videos, accuracy was 89.04%, and ENDOANGEL continuously showed the accumulated percentage of the images for different BBPS scores during the withdrawal phase and prompted us for bowel preparation scores every 30 seconds. CONCLUSIONS: We provided a novel and more accurate evaluation method for bowel preparation and developed an objective and stable system-ENDOANGEL-that could be applied reliably and steadily in clinical settings.

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Zhou J, Wu L, Wan X, et al. A novel artificial intelligence system for the assessment of bowel preparation (with video). Gastrointest Endosc. 2019. PMID: 31783029. doi:10.1016/j.gie.2019.11.026

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。