文献速递消化内镜食管胃疾病与幽门螺杆菌肝病

磁辅助胶囊内镜诊断巴雷特食管与食管静脉曲张

Diagnosis of Barrett's esophagus and esophageal varices using a magnetically assisted capsule endoscopy system.
PubMed 文献 · Gastrointest Endosc · 2019-10-31

一项先导研究纳入50例受试者(17例巴雷特食管、17例食管静脉曲张、16例对照),用磁辅助胶囊内镜(MACE)与胃镜(EGD)对照,操作者双盲。MACE诊断巴雷特食管敏感度93.8%、特异度100%,诊断食管静脉曲张敏感度73.3%、特异度100%,且更舒适、无不良事件。

要点

  • MACE诊断巴雷特食管敏感度93.8%、特异度100%,准确性高。
  • MACE诊断食管静脉曲张敏感度73.3%、特异度100%。
  • MACE耐受性与安全性好,舒适度评分优于胃镜。

核心结论

  • MACE安全且耐受良好,诊断巴雷特食管准确性高,可能用于该病的筛查。

研究设计与样本

  • 先导研究纳入50例受试者:34例已知病变(17例巴雷特食管、17例食管静脉曲张)和16例对照。
  • 受试者接受MACE检查,操作者对适应证和既往内镜诊断设盲;随后胃镜由对MACE结果设盲的内镜医师完成。

主要发现

  • 实时MACE正确诊断食管静脉曲张15例中的11例,敏感度73.3%(95%CI 44.9%-92.2%),特异度100%(95%CI 89.1%-100%)。
  • 实时MACE正确诊断巴雷特食管16例中的15例,敏感度93.8%(95%CI 69.8%-99.8%),特异度100%(95%CI 88.8%-100%)。
  • MACE舒适度评分平均9.2分,胃镜6.7分(10分制),差异有统计学意义(P < .0001)。
  • 未发生MACE或胃镜相关不良事件。

关键数值与推荐

  • 磁体可将胶囊在食管内保持平均190秒,最长634秒。

临床怎么用

  • MACE或可作为巴雷特食管的筛查工具,尤其适合追求舒适、社区场景的患者。
  • 对食管静脉曲张的诊断敏感度相对较低,需结合临床谨慎解读阴性结果。

局限性

  • 3例患者无法吞下胶囊,可能影响适用人群。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Magnetically assisted capsule endoscopy (MACE) potentially offers a comfortable, patient friendly, and community-based alternative to gastroscopy (EGD). This pilot study aims to explore whether this approach can be used to accurately diagnose Barrett's esophagus (BE) and esophageal varices. METHOD: The MiroCam Navi capsule system was used to examine the upper GI tract in patients due to undergo a clinically indicated EGD. A total of 50 participants were enrolled: 34 had known pathology (17 BE, 17 esophageal varices [EV]) and 16 controls. Patients underwent the MACE procedure with the operator blinded to the indication and any previous endoscopic diagnoses. The subsequent EGD was performed by an endoscopist blinded to the MACE findings. Diagnostic yield, comfort, and patient preference between the 2 modalities were compared. RESULTS: The mean age of the participants was 61 years, the male/female ratio was 2.1:1, the mean body mass index was 29.5 kg/m2, and the average chest measurement was 105.3 cm. Forty-seven patients underwent both procedures; 3 patients were unable to swallow the capsule. With the use of the magnet, it was possible to hold the capsule within the esophagus for a mean duration of 190 seconds and up to a maximum of 634 seconds. A correct real-time MACE diagnosis was made in 11 of 15 patients with EV (sensitivity 73.3% [95% confidence interval (CI), 44.9%-92.2%] and specificity 100% [95% CI, 89.1%-100%]) and 15 of 16 patients with BE (sensitivity 93.8% [95% CI, 69.8%-99.8%] and specificity of 100% [95% CI, 88.8%-100%]). MACE was considered more comfortable than conventional endoscopy (P < .0001); the mean score was 9.2 for MACE compared with 6.7 for EGD when assessed on a 10-point scale. No MACE- or EGD-related adverse events occurred. CONCLUSION: This pilot study demonstrates that MACE is both safe and well tolerated by patients. Accuracy for the diagnosis of BE was high, and therefore MACE may have a role in screening for this condition. (Clinical trial registration number: NCT02852161.).

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Beg S, Card T, Warburton S, et al. Diagnosis of Barrett's esophagus and esophageal varices using a magnetically assisted capsule endoscopy system. Gastrointest Endosc. 2019. PMID: 31678203. doi:10.1016/j.gie.2019.10.031

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。