文献速递消化内镜胰腺与胆道疾病

一次性十二指肠镜用于ERCP的临床评估

Clinical Evaluation of a Single-Use Duodenoscope for Endoscopic Retrograde Cholangiopancreatography.
PubMed 文献 · Clin Gastroenterol Hepatol · 2019-11-06

该研究在6个学术医疗中心连续纳入73例无胰腺胆道解剖改变的患者,由7名专家使用一次性十二指肠镜行ERCP。96.7%的ERCP仅用一次性十二指肠镜完成,3.3%需转换为 reusable 十二指肠镜,中位总体满意度为9分(满分10分)。

要点

  • 专家使用一次性十二指肠镜可完成绝大多数ERCP,仅3.3%需转换。
  • 术后胰腺炎3例,乳头括约肌切开后出血1例,感染加重再住院1例。
  • 一次性十二指肠镜可能降低ERCP相关感染风险。

核心结论

  • 专家内镜医师使用一次性十二指肠镜可完成几乎所有ERCP,且涵盖多种复杂度。

研究设计与样本

  • 2019年4月至5月在6个学术医疗中心开展病例系列研究,筛查连续患者(≥18岁)且无胰腺胆道解剖改变,共纳入73例。
  • 7名专家对13例患者行导入操作(仅十二指肠镜导航和十二指肠乳头可视),对60例患者行ERCP。

主要发现

  • 13例(100%)导入操作使用一次性十二指肠镜完成。
  • ERCP复杂度ASGE分级:1级7例(11.7%),2级26例(43.3%),3级26例(43.3%),4级1例(1.7%)。
  • 58例(96.7%)ERCP仅用一次性十二指肠镜完成,2例(3.3%)用一次性十二指肠镜后转换为可重复使用十二指肠镜。
  • 中位总体满意度为9分(满分10分)。
  • 3例发生ERCP后胰腺炎,1例发生乳头括约肌切开后出血,1例原有感染加重需再住院。

临床怎么用

  • 专家内镜医师可考虑使用一次性十二指肠镜完成ERCP,尤其适用于关注感染风险的场景。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND & AIMS: Disposable, single-use duodenoscopes might reduce outbreaks of infections associated with endoscope reuse. We tested the feasibility, preliminary safety, and performance of a new single-use duodenoscope in patients undergoing endoscopic retrograde cholangiopancreatography (ERCP). METHODS: We conducted a case-series study of the outcomes of ERCP with a single-use duodenoscope from April through May 2019 at 6 academic medical centers. We screened consecutive patients (18 years and older) without alterations in pancreaticobiliary anatomy and enrolled 73 patients into the study. Seven expert endoscopists performed roll-in maneuvers (duodenoscope navigation and visualization of duodenal papilla only) in 13 patients and then ERCPs in the 60 other patients. Outcomes analyzed included completion of ERCP for the intended clinical indication, crossover from a single-use duodenoscope to a reusable duodenoscope, endoscopist performance ratings of the device, and serious adverse events (assessed at 72 hours and 7 days). RESULTS: Thirteen (100%) roll-in maneuver cases were completed using the single-use duodenoscope. ERCPs were of American Society for Gastrointestinal Endoscopy procedural complexity grade 1 (least complex; 7 patients [11.7%]), grade 2 (26 patients [43.3%]), grade 3 (26 patients [43.3%]), and grade 4 (most complex; 1 patient [1.7%]). Fifty-eight ERCPs (96.7%) were completed using the single-use duodenoscope only and 2 ERCPs (3.3%) were completed using the single-use duodenoscope followed by crossover to a reusable duodenoscope. Median overall satisfaction was 9 out of 10. Three patients developed post-ERCP pancreatitis, 1 patient had post-sphincterotomy bleeding, and 1 patient had worsening of a preexisting infection and required rehospitalization. CONCLUSIONS: In a case-series study, we found that expert endoscopists can complete ERCPs of a wide range of complexity using a single-use duodenoscope for nearly all cases. This alternative might decrease ERCP-related risk of infection. Clinicaltrials.gov no: NCT03701958.

来源:Clin Gastroenterol Hepatol,查看原文。版权归原作者所有。

引用

  1. Muthusamy VR, Bruno MJ, Kozarek RA, et al. Clinical Evaluation of a Single-Use Duodenoscope for Endoscopic Retrograde Cholangiopancreatography. Clin Gastroenterol Hepatol. 2019. PMID: 31706060. doi:10.1016/j.cgh.2019.10.052

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。