文献速递胰腺与胆道疾病消化内镜消化道肿瘤与早癌

定性与定量超声内镜造影提升局灶性胰腺病变评估

Qualitative and Quantitative Contrast-enhanced Endoscopic Ultrasound Improves Evaluation of Focal Pancreatic Lesions.
PubMed 文献 · Clin Gastroenterol Hepatol · 2019-09-06

该前瞻性串联对照试验纳入101例局灶性胰腺病变患者,先常规EUS后行造影增强EUS,比较诊断准确率。

要点

  • 造影增强EUS较常规EUS显著提高局灶性胰腺病变诊断准确率(64%→91%)。
  • 造影增强EUS改善胰腺囊肿囊壁结节与碎屑的鉴别,准确率96% vs 71.4%。
  • 定量参数相对峰值增强和流入斜率可辅助区分腺癌、神经内分泌肿瘤和慢性胰腺炎。

核心结论

  • 造影增强EUS较常规EUS提高局灶性胰腺病变的诊断准确率,定量参数相对峰值增强和流入斜率可进一步提升诊断效能。

研究设计与样本

  • 前瞻性串联对照试验,纳入101例局灶性胰腺病变患者(48例肿块、28例囊肿、25例胰腺炎),均接受常规EUS后行造影增强EUS(静脉注射全氟丙烷微球)。
  • 以手术病理、细胞学和/或6个月临床随访为标准,比较两种方法的诊断准确率,并通过时间-强度曲线分析生成定量参数。
  • 实性病变分为推导队列和验证队列,对定量参数进行交叉验证分析。

主要发现

  • 造影增强EUS诊断准确率为91%(92/101),常规EUS为64%(65/101),OR 7.8(95%CI 2.7-30.2)。
  • 胰腺肿块诊断准确率OR 6.0(95%CI 1.8-31.8),改善神经内分泌肿瘤和其他非癌肿瘤的评估。
  • 时间-强度曲线显示:腺癌表现为低相对峰值增强和低流入斜率;神经内分泌肿瘤为高相对峰值增强和正常流入斜率;慢性胰腺炎灶为正常相对峰值增强和低流入斜率。
  • 验证队列中定量参数正确分类91%的病变,较常规EUS提高诊断准确率(OR 10,95%CI 1.4-34.0)。

关键数值与推荐

  • 造影增强EUS诊断准确率91% vs 常规EUS 64%(OR 7.8,95%CI 2.7-30.2)。
  • 胰腺肿块诊断准确率OR 6.0(95%CI 1.8-31.8)。
  • 验证队列中定量参数正确分类91%的病变,OR 10(95%CI 1.4-34.0)。

临床怎么用

  • 对局灶性胰腺病变,可在常规EUS基础上加做造影增强EUS以提高诊断准确率。
  • 利用时间-强度曲线定量参数(相对峰值增强和流入斜率)辅助鉴别胰腺癌、神经内分泌肿瘤和慢性胰腺炎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND & AIMS: Endoscopic ultrasound (EUS) is a sensitive method to evaluate the pancreas but its diagnostic capability for several diseases is limited. We compared the diagnostic yield of unenhanced EUS with that of contrast-enhanced EUS for focal pancreas lesions and identified and tested quantitative parameters of contrast enhancement. METHODS: We performed a prospective tandem-controlled trial in which 101 patients with focal pancreas lesions (48 with masses, 28 with cysts, and 25 with pancreatitis) underwent conventional EUS followed by contrast EUS using intravenous perflutren microspheres. The diagnosis at each stage was scored and compared with a standard (findings from surgical pathology analysis, cytologic, and/or 6-month clinical follow-up evaluations). Quantitative parameters were generated by time-intensity curve analysis. Solid lesions were divided into derivation and testing cohorts for a crossover validation analysis of the quantitative parameters. The primary outcome was diagnostic yield of unenhanced vs contrast EUS in analysis of focal pancreas lesions. RESULTS: Contrast increased the diagnostic yield of EUS from 64% (65/101 lesions accurately assessed) to 91% (92/101 lesions accurately assessed); the odds ratio [OR] was 7.8 (95% CI, 2.7-30.2) for accurate analysis of lesions by contrast-enhanced EUS relative to unenhanced EUS. The contrast increased accuracy of analysis of pancreas masses (OR, 6.0; 95% CI, 1.8-31.8), improving assessment of neuroendocrine and other (non-carcinoma) tumors. Contrast increased the diagnostic yield for pancreas cysts to 96% (27/28) compared with 71.4% (20/28) for unenhanced EUS (P = .02), due to improved differentiation of mural nodules vs debris. Time-intensity curve analysis revealed distinct patterns of relative peak enhancement (rPE) and in-slope (rIS) for different lesions following contrast injection: for adenocarcinomas, values were low rPE and low rIS; for neuroendocrine masses, values were high rPE and normal IS; and for chronic pancreatitis foci, values were normal rPE and low rIS. In the validation cohort, these parameters correctly characterized 91% of lesions and improved yield relative to unenhanced EUS (OR, 10; 95% CI, 1.4-34.0). CONCLUSIONS: Contrast-enhanced EUS improves the accuracy of analysis of focal pancreas lesions, compared with unenhanced EUS. Integration of practical quantitative parameters, specifically relative peak enhancement and in-slope, might increase the diagnostic accuracy of contrast EUS. ClinicalTrials.gov no: 02863770.

来源:Clin Gastroenterol Hepatol,查看原文。版权归原作者所有。

引用

  1. Buxbaum J, Ko C, Varghese N, et al. Qualitative and Quantitative Contrast-enhanced Endoscopic Ultrasound Improves Evaluation of Focal Pancreatic Lesions. Clin Gastroenterol Hepatol. 2019. PMID: 31499247. doi:10.1016/j.cgh.2019.08.054

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。