文献速递消化内镜消化道肿瘤与早癌

实时自动质量控制系统对结直肠息肉和腺瘤检出率的影响:前瞻性随机对照研究

Impact of a real-time automatic quality control system on colorectal polyp and adenoma detection: a prospective randomized controlled study (with videos).
PubMed 文献 · Gastrointest Endosc · 2019-08-24

本研究开发基于深度卷积神经网络的自动质量控制系统(AQCS),用于监督结肠镜退镜时间、退镜稳定性、肠道准备评估和息肉检测。659例患者随机分组,AQCS组腺瘤检出率(0.289 vs 0.165,P < .001)和人均腺瘤数(0.367 vs 0.178,P < .001)显著高于对照组。AQCS可有效改善结肠镜医师退镜阶段表现并提高息肉和腺瘤检出。

要点

  • AQCS显著提高腺瘤检出率(0.289 vs 0.165,P < .001)。
  • AQCS组退镜时间更长(7.03 vs 5.68分钟,P < .001)。
  • AQCS未报告严重不良事件或系统故障。

核心结论

  • AQCS可有效改善结肠镜医师退镜阶段表现,并显著提高息肉和腺瘤检出。

研究设计与样本

  • 前瞻性随机对照研究,共纳入659例患者,AQCS组308例和对照组315例纳入分析。

主要发现

  • AQCS组腺瘤检出率显著高于对照组(0.289 vs 0.165,P < .001)。
  • AQCS组人均腺瘤数显著高于对照组(0.367 vs 0.178,P < .001)。
  • AQCS组息肉检出率显著高于对照组(0.383 vs 0.254,P = .001)。
  • AQCS组人均息肉数显著高于对照组(0.575 vs 0.305,P < .001)。
  • AQCS组退镜时间(7.03分钟 vs 5.68分钟,P < .001)和充分肠道准备率(87.34% vs 80.63%,P = .023)均优于对照组。

临床怎么用

  • 临床可考虑在结肠镜退镜阶段引入AQCS辅助,以提高腺瘤和息肉检出率。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Quality control can decrease variations in the performance of colonoscopists and improve the effectiveness of colonoscopy to prevent colorectal cancers. Unfortunately, routine quality control is difficult to carry out because a practical method is lacking. The aim of this study was to develop an automatic quality control system (AQCS) and assess whether it could improve polyp and adenoma detection in clinical practice. METHODS: First, we developed AQCS based on deep convolutional neural network models for timing of the withdrawal phase, supervising withdrawal stability, evaluating bowel preparation, and detecting colorectal polyps. Next, consecutive patients were prospectively randomized to undergo routine colonoscopies with or without the assistance of AQCS. The primary outcome of the study was the adenoma detection rate (ADR) in the AQCS and control groups. RESULTS: A total of 659 patients were enrolled and randomized. A total of 308 and 315 patients were analyzed in the AQCS and control groups, respectively. AQCS significantly increased the ADR (0.289 vs 0.165, P < .001) and the mean number of adenomas per procedure (0.367 vs 0.178, P < .001) compared with the control group. A significant increase was also observed in the polyp detection rate (0.383 vs 0.254, P = .001) and the mean number of polyps detected per procedure (0.575 vs 0.305, P < .001). In addition, the withdrawal time (7.03 minutes vs 5.68 minutes, P < .001) and adequate bowel preparation rate (87.34% vs 80.63%, P = .023) were superior for the AQCS group. CONCLUSIONS: AQCS could effectively improve the performance of colonoscopists during the withdrawal phase and significantly increase polyp and adenoma detection. (Clinical trial registration number: NCT03622281.).

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Su JR, Li Z, Shao XJ, et al. Impact of a real-time automatic quality control system on colorectal polyp and adenoma detection: a prospective randomized controlled study (with videos). Gastrointest Endosc. 2019. PMID: 31454493. doi:10.1016/j.gie.2019.08.026

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。