文献速递肝病消化内镜

超细胃镜对比常规胃镜诊断肝硬化食管静脉曲张的系统综述与Meta分析

Systematic review with meta-analysis: ultra-thin gastroscopy compared to conventional gastroscopy for the diagnosis of oesophageal varices in people with cirrhosis.
PubMed 文献 · Aliment Pharmacol Ther · 2019-05-06

该系统综述与Meta分析纳入10项研究共752例受试者,评估超细胃镜对比常规胃镜诊断肝硬化食管静脉曲张的准确性。汇总敏感度为98%(95%CI 93%-99%),特异度为96%(95%CI 91%-99%),未报告与超细胃镜相关的严重不良事件。作者认为超细胃镜诊断食管静脉曲张准确、安全且耐受良好,是常规胃镜用于肝硬化患者静脉曲张筛查和监测的有效替代方法。

要点

  • 超细胃镜诊断食管静脉曲张的汇总敏感度98%、特异度96%。
  • 汇总阳性似然比28、阴性似然比0.02,未报告相关严重不良事件。
  • 作者认为超细胃镜是肝硬化患者静脉曲张筛查和监测的有效替代方法。

核心结论

  • 超细胃镜诊断食管静脉曲张准确、安全且耐受良好,作者认为其是常规胃镜用于肝硬化患者静脉曲张筛查和监测的有效替代方法。

研究设计与样本

  • 系统综述与Meta分析,检索MEDLINE、EMBASE和Cochrane图书馆数据库,纳入评估超细胃镜对比常规胃镜诊断食管静脉曲张准确性的研究。
  • 共纳入10项研究、752例受试者,其中7项研究在已知肝硬化患者中进行。

主要发现

  • 纳入研究的食管静脉曲张总体患病率为42%。
  • 双变量模型汇总敏感度为98%(95%CI 93%-99%),汇总特异度为96%(95%CI 91%-99%)。
  • 汇总阳性似然比为28(95%CI 10.7-73.2),汇总阴性似然比为0.02(95%CI 0.01-0.72)。
  • 任何静脉曲张的观察者间一致性Kappa系数范围为0.45至0.90。
  • 未报告与超细胃镜相关的严重不良事件。

关键数值与推荐

  • 超细胃镜使用镜身直径≤6 mm的内镜。
  • 常规胃镜是静脉曲张筛查的参考标准。
  • 指南推荐在肝硬化诊断时及整个病程中筛查静脉曲张。

临床怎么用

  • 作者认为超细胃镜是常规胃镜用于肝硬化患者静脉曲张筛查和监测的有效替代方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Haemorrhage from ruptured oesophageal varices is a common cause of death in people with cirrhosis. Guidelines recommend screening for varices at time of cirrhosis diagnosis and throughout the course of the disease. Conventional gastroscopy is the criterion standard for variceal screening; however, is invasive, costly, and carries risks related to use of sedation. Ultra-thin gastroscopy (using endoscopes with a shaft diameter ≤6 mm) has been proposed as an alternative method of variceal screening that mitigates these risks. AIM: To determine the diagnostic accuracy of ultra-thin gastroscopy compared to conventional gastroscopy for the diagnosis of varices in people with cirrhosis. METHODS: MEDLINE, EMBASE and Cochrane library databases were searched for studies that evaluated the accuracy of ultra-thin gastroscopy compared to conventional gastroscopy in the diagnosis of oesophageal varices. RESULTS: Ten studies, 7 in known cirrhosis, with 752 participants were included in this systematic review. The overall prevalence of oesophageal varices was 42%. On bivariate modelling, pooled estimates of sensitivity and specificity were 98% (95% CI 93%-99%) and 96% (95% CI 91%-99%) respectively. The positive and negative likelihood ratios were 28 (95% CI 10.7-73.2) and 0.02 (95% CI 0.01-0.72) respectively. Kappa coefficient for inter-observer agreement for any varices ranged from 0.45 to 0.90. No serious adverse events related to ultra-thin gastroscopy were reported. CONCLUSIONS: Ultra-thin gastroscopy is accurate in the diagnosis of oesophageal varices, safe and well tolerated. It is a valid alternative to conventional gastroscopy for the screening and surveillance of varices in people with cirrhosis.

来源:Aliment Pharmacol Ther,查看原文。版权归原作者所有。

引用

  1. Wickremeratne T, Turner S, O'Beirne J, et al. Systematic review with meta-analysis: ultra-thin gastroscopy compared to conventional gastroscopy for the diagnosis of oesophageal varices in people with cirrhosis. Aliment Pharmacol Ther. 2019. PMID: 31059160. doi:10.1111/apt.15282

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。