文献速递消化内镜消化道肿瘤与早癌

视频监视器尺寸对息肉检出率的影响:一项前瞻性随机对照试验

Effect of video monitor size on polyp detection: a prospective, randomized, controlled trial.
PubMed 文献 · Gastrointest Endosc · 2019-04-12

该单中心前瞻性随机对照试验于2013年10月至2014年4月在三级转诊医院门诊中心比较32英寸与19英寸对角线视频监视器对结肠镜腺瘤检出率(ADR)和息肉检出率(PDR)的影响。15名内镜医师完成1795例门诊结肠镜检查,结果显示32英寸组与19英寸组ADR(27.4% vs 27.9%,P=0.80)和PDR(32.8% vs 34.4%,P=0.50)均无显著差异,分层及多变量分析结果一致。结论不支持更大视频监视器可提高ADR的观点。

要点

  • 32英寸与19英寸监视器组ADR分别为27.4%和27.9%,无显著差异(P=0.80)。
  • 两组PDR分别为32.8%和34.4%,无显著差异(P=0.50)。
  • 按指征、盲肠插管、肠道准备、操作者经验及检查时间分层后结果仍无显著改变。

核心结论

  • 本试验结果不支持更大视频监视器可提高腺瘤检出率的观点。
  • 未来提高腺瘤检出率的努力应聚焦于结肠镜检查的其他方面。

研究设计与样本

  • 单中心、前瞻性、随机对照临床试验,内镜医师按日随机分配使用32英寸或19英寸对角线视频监视器进行常规门诊结肠镜检查。
  • 研究于2013年10月至2014年4月在三级转诊医院门诊中心开展,15名内镜医师共完成1795例门诊结肠镜检查(平均年龄55岁,女性56%,筛查指征56%)。
  • 两组基线患者特征无实质性差异。

主要发现

  • 32英寸组与19英寸组总体ADR分别为27.4%与27.9%,无显著差异(P=0.80)。
  • 32英寸组与19英寸组总体PDR分别为32.8%与34.4%,无显著差异(P=0.50)。
  • 按指征、盲肠插管、肠道准备、操作者经验及检查时间分层,以及将这些变量作为潜在混杂因素纳入多变量模型后,结果均无显著改变(所有P>0.05)。
  • 总体而言,每位内镜医师的ADR和PDR似乎不受监视器尺寸影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: The adenoma detection rate (ADR) is the most important quality metric for colonoscopy. Numerous factors are known to influence ADR. However, no data on the effect of monitor size on ADR exist. The aim of this study was to compare the ADR and polyp detection rate (PDR) achieved using 2 different-size video monitors (19-inch diagonal and 32-inch diagonal). METHODS: In a single-center, prospective, randomized clinical trial, endoscopists were randomized on a daily basis to perform routine ambulatory colonoscopies with either a 32-inch diagonal or a 19-inch diagonal video monitor. RESULTS: The study was conducted between October 2013 and April 2014 in an outpatient center of a tertiary referral hospital. Fifteen endoscopists performed 1795 outpatient colonoscopies (mean age, 55 years; 56% women; screening, 56%). There was no substantial difference in baseline patient characteristics between the 2 arms. The overall ADR (27.4% vs 27.9%; P = .80) and PDR (32.8% vs 34.4%; P = .50) were not significantly different between the 32-inch and 19-inch monitor group, respectively. The findings were not significantly altered when stratified by indication, cecal intubation, bowel preparation, operator experience, and time of endoscopy as well as in a multivariable model that included these variables as potential confounders (all P > .05). Overall, the ADR and PDR for each individual endoscopist did not appear to be influenced by monitor size. CONCLUSIONS: The results of this trial do not support the notion that larger video monitors improve ADR. Future efforts to increase ADR should focus on other aspects of colonoscopy. (Clinical trial registration number: NCT01952418.).

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Jovani M, Campbell EJ, Hur C, et al. Effect of video monitor size on polyp detection: a prospective, randomized, controlled trial. Gastrointest Endosc. 2019. PMID: 30986402. doi:10.1016/j.gie.2019.03.1172

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。