窄带成像在结肠镜检查中检测肿瘤性病变:随机对照试验个体患者数据的荟萃分析
该研究检索MEDLINE、EMBASE和Cochrane图书馆数据库至2017年4月,纳入11项随机对照试验的4491例患者个体数据,比较窄带成像(NBI)与白光内镜(WLE)检测结肠腺瘤的效果。主要结局为按肠道准备质量调整的腺瘤检出率(ADR)。结果显示NBI组ADR高于WLE组,且该优势在肠道准备最佳时更明显,第二代明亮NBI的ADR优于WLE,而第一代NBI则无此优势。
要点
- NBI组腺瘤检出率高于WLE组(45.2% vs 42.3%,未调整OR 1.14,95%CI 1.01-1.29,P=0.04)。
- 肠道准备最佳时NBI优于WLE(OR 1.30,95%CI 1.04-1.62,P=0.02),准备充分时无显著差异(OR 1.07,95%CI 0.92-1.24,P=0.38)。
- 第二代明亮NBI的ADR优于WLE(OR 1.28,95%CI 1.05-1.56,P=0.02),第一代NBI则无此优势。
核心结论
- 在随机对照试验个体患者数据的荟萃分析中,NBI的腺瘤检出率高于WLE,且肠道准备最佳时该效应更强。
研究设计与样本
- 检索MEDLINE、EMBASE和Cochrane图书馆数据库至2017年4月,纳入比较高清WLE与NBI检测结肠息肉且可获得个体患者数据的随机对照试验,共11项试验、4491例患者、检出6636枚息肉。
- 采用多水平回归模型,患者嵌套于试验内,试验作为随机效应。
主要发现
- WLE组2251例中952例(42.3%)检出腺瘤,NBI组2239例中1011例(45.2%)检出腺瘤(未调整OR 1.14,95%CI 1.01-1.29,P=0.04)。
- 肠道准备充分时OR 1.07(95%CI 0.92-1.24,P=0.38),肠道准备最佳时OR 1.30(95%CI 1.04-1.62,P=0.02)。
- 第二代明亮NBI的ADR优于WLE(OR 1.28,95%CI 1.05-1.56,P=0.02),第一代NBI则无此优势。
- NBI检出的非腺瘤性息肉多于WLE(OR 1.24,95%CI 1.06-1.44,P=0.008),检出的扁平息肉也多于WLE(OR 1.24,95%CI 1.02-1.51,P=0.03)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND & AIMS: Adenoma detection rate (ADR) is an important quality assurance measure for colonoscopy. Some studies suggest that narrow-band imaging (NBI) may be more effective at detecting adenomas than white-light endoscopy (WLE) when bowel preparation is optimal. We conducted a meta-analysis of data from individual patients in randomized controlled trials that compared the efficacy of NBI to WLE in detection of adenomas. METHODS: We searched MEDLINE, EMBASE, and Cochrane Library databases through April 2017 for randomized controlled trials that assessed detection of colon polyps by high-definition WLE vs NBI and from which data on individual patients were available. The primary outcome measure was ADR adjusted for bowel preparation quality. Multilevel regression models were used with patients nested within trials, and trial included as a random effect. RESULTS: We collected data from 11 trials, comprising 4491 patients and 6636 polyps detected. Adenomas were detected in 952 of 2251 (42.3%) participants examined by WLE vs 1011 of 2239 (45.2%) participants examined by NBI (unadjusted odds ratio [OR] for detection of adenoma by WLE vs NBI, 1.14; 95% CI, 1.01-1.29; P = .04). NBI outperformed WLE only when bowel preparation was best: adequate preparation OR, 1.07 (95% CI, 0.92-1.24; P = .38) vs best preparation OR, 1.30 (95% CI, 1.04-1.62; P = .02). Second-generation bright NBI had a better ADR than WLE (second-generation NBI OR, 1.28; 95% CI, 1.05-1.56; P = .02), whereas first-generation NBI did not. NBI detected more non-adenomatous polyps than WLE (OR, 1.24; 95% CI, 1.06-1.44; P = .008) and flat polyps than WLE (OR, 1.24; 95% CI, 1.02-1.51; P = .03). CONCLUSIONS: In a meta-analysis of data from individual patients in randomized controlled trials, we found NBI to have a higher ADR than WLE, and that this effect is greater when bowel preparation is optimal.
引用
- Atkinson NSS, Ket S, Bassett P, et al. Narrow-Band Imaging for Detection of Neoplasia at Colonoscopy: A Meta-analysis of Data From Individual Patients in Randomized Controlled Trials. Gastroenterology. 2019. PMID: 30998991. doi:10.1053/j.gastro.2019.04.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。