文献速递消化内镜消化道肿瘤与早癌

口服西甲硅油对筛查性结肠镜检查腺瘤检出率及其他质量指标的作用:一项随机对照观察者盲法临床试验

The role of oral simethicone on the adenoma detection rate and other quality indicators of screening colonoscopy: a randomized, controlled, observer-blinded clinical trial.
PubMed 文献 · Gastrointest Endosc · 2019-03-26

该随机对照观察者盲法临床试验将筛查性结肠镜检查患者随机分配至聚乙二醇联合西甲硅油组或单用聚乙二醇组,比较腺瘤检出率等指标。结果显示两组腺瘤检出率(33.3% vs 38.8%;P = .881)和有效操作时间(759.3 ± 253.1秒 vs 800.2 ± 459.6秒;P = .373)无显著差异,但联合西甲硅油组术中追加西甲硅油比例(1.6% vs 48.9%;P ≤ .05)和气泡评分(0.1 vs 2.1;P ≤ .05)显著更低。

要点

  • 聚乙二醇联合西甲硅油组与单用聚乙二醇组的腺瘤检出率分别为33.3%和38.8%,无显著差异(P = .881)。
  • 联合西甲硅油组术中追加西甲硅油比例为1.6%,显著低于单用聚乙二醇组的48.9%(P ≤ .05)。
  • 联合西甲硅油组气泡评分0.1,显著低于单用聚乙二醇组的2.1(P ≤ .05)。

核心结论

  • 在聚乙二醇肠道准备中加入西甲硅油未改善腺瘤检出率或有效操作时间,但降低了气泡评分和术中追加西甲硅油的使用。

研究设计与样本

  • 随机、对照、观察者盲法临床试验,纳入接受筛查性结肠镜检查的患者,排除结直肠癌高风险患者,随机分配至聚乙二醇联合西甲硅油组或单用聚乙二醇组。

主要发现

  • 聚乙二醇联合西甲硅油组与单用聚乙二醇组的腺瘤检出率分别为33.3%和38.8%,无显著差异(P = .881)。
  • 聚乙二醇联合西甲硅油组与单用聚乙二醇组的有效操作时间分别为759.3 ± 253.1秒和800.2 ± 459.6秒,无显著差异(P = .373)。
  • 聚乙二醇联合西甲硅油组术中追加西甲硅油比例为1.6%,显著低于单用聚乙二醇组的48.9%(P ≤ .05)。
  • 聚乙二醇联合西甲硅油组气泡评分为0.1,显著低于单用聚乙二醇组的2.1(P ≤ .05)。
  • 两组波士顿肠道准备量表(BBPS)评分无差异;气泡评分观察者间一致性较强(kappa = .537;P < .05),BBPS评分观察者间一致性kappa = .184(P < .05)。

临床怎么用

  • 作者认为这一简单且廉价的干预可能具有降低内镜传播感染风险的潜力。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Combining simethicone (SIM) with a colon preparation agent has been shown to improve mucosal visibility during screening colonoscopy, but its effect on the adenoma detection rate (ADR) remains unclear. SIM is commonly used through the endoscope to eliminate bubbles during endoscopy. However, this practice recently has been associated with endoscope-transmitted infections. Our aims were to determine the role of SIM added to a polyethylene glycol preparation on the ADR, procedure times, colon preparation, and intraprocedural use of SIM. METHODS: This was a randomized, controlled, observer-blinded, clinical trial of patients undergoing screening colonoscopy. Patients with a high risk of colorectal cancer were excluded. Patients were randomly assigned to 2 different preparations: polyethylene glycol plus SIM or polyethylene glycol. Two endoscopists blinded to patient preparation regimens scored its quality by using the Boston Bowel Preparation scale (BBPS) and the bubble scale. Interobserver agreement was calculated. The polyp detection rate, ADR, intraprocedural use of SIM, cecal intubation time, and withdrawal time were recorded. For study purposes, cecal intubation time and withdrawal time were combined to determine the effective procedure time. RESULTS: No significant difference between the polyethylene glycol plus SIM and polyethylene glycol arms was seen regarding the ADR (33.3% vs 38.8%; P = .881) and effective procedure time (759.3 ± 253.1 seconds vs 800.2 ± 459.6 seconds; P = .373), respectively. Intraprocedural use of SIM as well as the bubble scale score were significantly lower in the polyethylene glycol plus SIM arm (1.6% vs 48.9%; P ≤ .05) and (0.1 vs 2.1; P ≤ .05), respectively. Conversely, no difference was found in the BBPS scores. The interobserver agreement for both scores was strong (bubble scale score kappa = .537; P < .05; BBPS score kappa = .184; P <.05). CONCLUSION: Adding SIM to a polyethylene glycol preparation did not improve the ADR or effective procedure time. Nevertheless, it resulted in lower bubble scale scores, and more importantly, in less intraprocedural use of SIM. This simple and inexpensive intervention may have the potential to reduce the risk of endoscope-transmitted infections. (Clinical trial registration number: NCT03119168.).

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Moraveji S, Casner N, Bashashati M, et al. The role of oral simethicone on the adenoma detection rate and other quality indicators of screening colonoscopy: a randomized, controlled, observer-blinded clinical trial. Gastrointest Endosc. 2019. PMID: 30926430. doi:10.1016/j.gie.2019.03.018