文献速递消化内镜消化道肿瘤与早癌

实时自动检测系统提高结肠镜息肉和腺瘤检出率:一项前瞻性随机对照研究

Real-time automatic detection system increases colonoscopic polyp and adenoma detection rates: a prospective randomised controlled study.
PubMed 文献 · Gut · 2019-02-27

该开放、非盲法前瞻性随机对照试验将1058例连续患者随机分为标准结肠镜组(536例)和计算机辅助诊断结肠镜组(522例),评估基于深度学习的实时自动息肉检测系统对腺瘤检出率(ADR)的影响。结果显示AI系统显著提高ADR(29.1% vs 20.3%,p<0.001)和人均腺瘤数(0.53 vs 0.31,p<0.001),主要归因于小腺瘤检出增多(185 vs 102,p<0.001),而较大腺瘤无统计学差异(77 vs 58,p=0.075)。

要点

  • AI辅助结肠镜使ADR从20.3%升至29.1%(p<0.001)。
  • 人均腺瘤数AI组0.53 vs 标准组0.31(p<0.001)。
  • 小腺瘤检出数AI组185 vs 标准组102(p<0.001),较大腺瘤无统计学差异。

核心结论

  • 在低ADR患病率人群中,结肠镜期间使用自动息肉检测系统使检出的小腺瘤数量显著增加,同时增生性息肉检出率也增加;此类效应的成本效益比有待进一步确定。

研究设计与样本

  • 开放、非盲法前瞻性随机对照试验,连续患者随机接受诊断性结肠镜伴或不伴实时自动息肉检测系统辅助,该系统在检测到息肉时提供同步视觉提示和声音警报;共纳入1058例患者,标准结肠镜组536例,计算机辅助诊断组522例。

主要发现

  • AI系统显著提高ADR(29.1% vs 20.3%,p<0.001)和人均腺瘤数(0.53 vs 0.31,p<0.001)。
  • 小腺瘤检出数AI组185 vs 标准组102(p<0.001),较大腺瘤检出数AI组77 vs 标准组58(p=0.075),无统计学差异。
  • 增生性息肉检出数AI组114 vs 标准组52(p<0.001),显著增加。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The effect of colonoscopy on colorectal cancer mortality is limited by several factors, among them a certain miss rate, leading to limited adenoma detection rates (ADRs). We investigated the effect of an automatic polyp detection system based on deep learning on polyp detection rate and ADR. DESIGN: In an open, non-blinded trial, consecutive patients were prospectively randomised to undergo diagnostic colonoscopy with or without assistance of a real-time automatic polyp detection system providing a simultaneous visual notice and sound alarm on polyp detection. The primary outcome was ADR. RESULTS: Of 1058 patients included, 536 were randomised to standard colonoscopy, and 522 were randomised to colonoscopy with computer-aided diagnosis. The artificial intelligence (AI) system significantly increased ADR (29.1%vs20.3%, p<0.001) and the mean number of adenomas per patient (0.53vs0.31, p<0.001). This was due to a higher number of diminutive adenomas found (185vs102; p<0.001), while there was no statistical difference in larger adenomas (77vs58, p=0.075). In addition, the number of hyperplastic polyps was also significantly increased (114vs52, p<0.001). CONCLUSIONS: In a low prevalent ADR population, an automatic polyp detection system during colonoscopy resulted in a significant increase in the number of diminutive adenomas detected, as well as an increase in the rate of hyperplastic polyps. The cost-benefit ratio of such effects has to be determined further. TRIAL REGISTRATION NUMBER: ChiCTR-DDD-17012221; Results.

来源:Gut,查看原文。版权归原作者所有。

引用

  1. Wang P, Berzin TM, Glissen Brown JR, et al. Real-time automatic detection system increases colonoscopic polyp and adenoma detection rates: a prospective randomised controlled study. Gut. 2019. PMID: 30814121. doi:10.1136/gutjnl-2018-317500

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。