文献速递消化内镜消化道肿瘤与早癌

注水交换结肠镜检查提高腺瘤检出率:随机对照研究的系统评价与网状Meta分析

Water exchange colonoscopy increases adenoma detection rate: a systematic review with network meta-analysis of randomized controlled studies.
PubMed 文献 · Gastrointest Endosc · 2018-07-05

该系统评价与网状Meta分析纳入17项随机对照试验共10350例患者,比较注水交换、注水浸泡与气体(空气或二氧化碳)灌注结肠镜检查对腺瘤检出率等结局的影响。结果显示注水交换较注水浸泡、空气和二氧化碳均显著提高总体腺瘤检出率,在右半结肠及结直肠癌筛查人群中亦最高,但进镜时间延长3-5分钟。

要点

  • 注水交换较注水浸泡、空气和二氧化碳灌注均显著提高总体腺瘤检出率。
  • 注水交换在右半结肠及结直肠癌筛查人群中腺瘤检出率最高,且波士顿肠道准备量表清洁度评分显著更高。
  • 注水交换和注水浸泡均增加非镇静检查比例并降低进镜实时疼痛,注水交换进镜疼痛最轻。

核心结论

  • 注水交换显著提高总体腺瘤检出率、筛查人群腺瘤检出率及右半结肠腺瘤检出率,并改善肠道清洁度,但需要更长的进镜时间。

研究设计与样本

  • 系统检索多个数据库,纳入比较注水浸泡和/或注水交换与空气和/或二氧化碳灌注并报告腺瘤检出率的随机对照试验,共17项随机对照试验、10350例患者,进行混合比较的网状Meta分析。

主要发现

  • 注水交换总体腺瘤检出率显著高于注水浸泡(OR 1.31;95% CrI 1.12-1.55)、空气(OR 1.40;CrI 1.22-1.62)和二氧化碳(OR 1.48;95% CrI 1.15-1.86)。
  • 注水交换在右半结肠和结直肠癌筛查病例中腺瘤检出率最高,均显著高于空气和注水浸泡。
  • 在采用分次剂量肠道准备的患者中,注水交换腺瘤检出率显著高于所有其他技术。
  • 注水交换的波士顿肠道准备量表清洁度评分显著高于空气和注水浸泡。
  • 注水交换和注水浸泡均增加非镇静检查比例并降低进镜实时疼痛,注水交换为进镜疼痛最轻的技术;各技术退镜时间相当,但注水交换进镜时间最长(延长3-5分钟)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Water-aided colonoscopy techniques, such as water immersion (WI) and water exchange (WE), have shown different results regarding adenoma detection rate (ADR). We determined the impact of WI and WE on ADR and other procedural outcomes versus gas (air, AI; CO2) insufflation colonoscopy. METHODS: A systematic search of multiple databases for randomized controlled trials comparing WI and/or WE with AI and/or CO2 and reporting ADR was conducted. A network meta-analysis with mixed comparisons was performed. Primary outcome was ADR (overall, in the right side of the colon and by colonoscopy indication). RESULTS: Seventeen randomized controlled trials (10,350 patients) were included. WE showed a significantly higher overall ADR versus WI (odds ratio [OR], 1.31; 95% credible interval [CrI], 1.12-1.55) versus AI (OR, 1.40; CrI, 1.22-1.62) versus CO2 (OR, 1.48; 95% CrI, 1.15-1.86). WE achieved the highest ADR also in the right side of the colon and in colorectal cancer screening cases (both significant vs AI and WI) as well as in patients taking a split-dose preparation (significant vs all the other techniques). The Boston Bowel Preparation Scale cleanliness score (vs AI and WI) was significantly higher for WE. Both WI and WE showed increased proportion of unsedated examinations and decreased real-time insertion pain, with WE being the least-painful insertion technique. Withdrawal time was comparable across techniques, but WE showed the longest insertion time (3-5 additional minutes). CONCLUSIONS: WE significantly increases overall ADR, ADR in screening cases, and in the right side of the colon; it also improves colon cleanliness but requires a longer insertion time.

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Fuccio L, Frazzoni L, Hassan C, et al. Water exchange colonoscopy increases adenoma detection rate: a systematic review with network meta-analysis of randomized controlled studies. Gastrointest Endosc. 2018. PMID: 29981753. doi:10.1016/j.gie.2018.06.028

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。