该系统综述与Meta分析检索MEDLINE与Embase至2017年9月,纳入45项研究共20,887名受试者,比较新型技术设备(NTDs)与常规结肠镜的腺瘤检出率(ADR)、息肉检出率(PDR)和腺瘤漏诊率(AMR)。NTDs的ADR(OR 1.35)和PDR(OR 1.51)更高,AMR更低(OR 0.19);机械NTDs的ADR和PDR高于光学NTDs,AMR低于光学NTDs;盲肠插管率、盲肠插管时间和结肠镜总时间无差异。

要点

  • NTDs较常规结肠镜提高ADR(OR 1.35;95%CI 1.24-1.47;P<.01)和PDR(OR 1.51;95%CI 1.37-1.67;P<.01)。
  • NTDs较常规结肠镜降低AMR(OR 0.19;95%CI 0.14-0.26;P<.01)。
  • 机械NTDs的ADR和PDR高于光学NTDs,AMR低于光学NTDs(OR 0.10 vs 0.33;P<.01)。

核心结论

  • 新型内镜技术是提高ADR和PDR、降低AMR的有效选择,尤其是机械NTDs;可操作性与安全性无差异。

研究设计与样本

  • 系统综述与Meta分析,检索MEDLINE和Embase自建库至2017年9月的文献或摘要。
  • 纳入报告NTDs的ADR、PDR和AMR的随机对照试验和病例对照研究,受试者>10例。
  • 从141条引文中共纳入45项研究、20,887名受试者进入至少1项分析。

主要发现

  • NTDs的ADR(OR 1.35;95%CI 1.24-1.47;P<.01)和PDR(OR 1.51;95%CI 1.37-1.67;P<.01)高于常规结肠镜。
  • 机械NTDs的ADR(OR 1.52 vs 1.25;P=.035)和PDR(OR 1.63 vs 1.10;P≤.01)更高。
  • NTDs的AMR低于常规结肠镜(OR 0.19;95%CI 0.14-0.26;P<.01)。
  • 机械NTDs的AMR低于光学NTDs(OR 0.10 vs 0.33;P<.01)。
  • 盲肠插管率、盲肠插管时间和结肠镜总时间无差异。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: The need to increase the adenoma detection rate (ADR) for colorectal cancer screening has ushered in devices that mechanically or optically improve conventional colonoscopy. Recently, new technology devices (NTDs) have become available. We aimed to compare the ADR, polyp detection rate (PDR), and adenoma miss rate (AMR) between NTDs and conventional colonoscopy and between mechanical and optical NTDs. METHODS: MEDLINE and Embase databases were searched from inception through September 2017 for articles or abstracts reporting ADR, PDR, and AMR with NTDs. Randomized controlled trials and case-control studies with >10 subjects were included. Primary outcomes included ADR, PDR, and AMR odds ratio (OR) between conventional colonoscopy and NTDs. Secondary outcomes included cecal intubation rates, adverse events, cecal intubation time, and total colonoscopy time. RESULTS: From 141 citations, 45 studies with 20,887 subjects were eligible for ≥1 analyses. Overall, the ORs for ADR (1.35; 95% confidence interval [CI] 1.24-1.47; P < .01) and PDR (1.51; 95% CI, 1.37-1.67; P < .01) were higher with NTDs. Higher ADR (OR, 1.52 vs 1.25; P = .035) and PDR (OR, 1.63 vs 1.10; P ≤ .01) were observed with mechanical NTDs. The overall AMR with NTDs was lower compared with conventional colonoscopy (OR, .19; 95% CI, .14-.26; P < .01). Mechanical NTDs had lower AMRs compared with optical NTDs (OR, .10 vs .33; P < .01). No differences in cecal intubation rates, cecal intubation time, or total colonoscopy time were found. CONCLUSIONS: Newer endoscopic technologies are an effective option to improve ADR and PDR and decrease AMR, particularly with mechanical NTDs. No differences in operability and safety were found.