文献速递消化内镜胰腺与胆道疾病

十二指肠镜消化道细菌高感染率:一项全国性研究

High prevalence rate of digestive tract bacteria in duodenoscopes: a nationwide study.
PubMed 文献 · Gut · 2018-04-10

荷兰全国73家ERCP中心中67家参与,按统一方法采样155条十二指肠镜的745个位点。22%的十二指肠镜和39%的中心存在≥20 CFU/20mL的微生物污染,15%的镜检出消化道或口腔来源微生物;污染与十二指肠镜型号无关。

要点

  • 39%的荷兰ERCP中心至少检出1条AM20污染的备用十二指肠镜
  • 15%的十二指肠镜检出消化道或口腔来源微生物,提示消毒失败
  • 污染率与十二指肠镜型号无关(p值均≥0.20)

核心结论

  • 39%的荷兰ERCP中心至少检出1条AM20污染的备用十二指肠镜
  • 15%的十二指肠镜携带消化道或口腔来源微生物,提示既往患者残留有机物即消毒失败
  • 结果提示现行再处理与过程控制程序不充分且不安全

研究设计与样本

  • 荷兰全国性横断面研究,邀请全部73家ERCP中心参与
  • 67家中心(92%)参与,采样155条十二指肠镜的745个位点
  • 使用中心分发的试剂盒按统一采样方法采样,视频说明操作,根据镜型采样4至6个位点并集中培养

主要发现

  • 33条(22%)十二指肠镜来自26家(39%)中心符合AM20污染定义
  • 23条(15%)十二指肠镜检出MGO,包括阴沟肠杆菌、大肠埃希菌、肺炎克雷伯菌和酵母
  • 采样涵盖3家制造商的10种十二指肠镜型号,包括69条(46%)Olympus TJF-Q180V、43条(29%)Olympus TJF-160VR、11条(7%)Pentax ED34-i10T、8条(5%)Pentax ED-3490TK和5条(3%)Fujifilm ED-530XT8
  • 两种定义下污染均不依赖十二指肠镜型号(p值分别为0.20和更高)

关键数值与推荐

  • 污染定义1(AM20):任何微生物≥20菌落形成单位(CFU)/20 mL
  • 污染定义2(MGO):存在消化道或口腔来源微生物,不论CFU计数

临床怎么用

  • 原文未据此给出推荐

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Increasing numbers of outbreaks caused by contaminated duodenoscopes used for Endoscopic Retrograde Cholangiopancreatography (ERCP) procedures have been reported, some with fatal outcomes. We conducted a nationwide cross-sectional study to determine the prevalence of bacterial contamination of reprocessed duodenoscopes in The Netherlands. DESIGN: All 73 Dutch ERCP centres were invited to sample ≥2 duodenoscopes using centrally distributed kits according to uniform sampling methods, explained by video instructions. Depending on duodenoscope type, four to six sites were sampled and centrally cultured. Contamination was defined as (1) any microorganism with ≥20 colony forming units (CFU)/20 mL (AM20) and (2) presence of microorganisms with gastrointestinal or oral origin, independent of CFU count (MGO). RESULTS: Sixty-seven out of 73 centres (92%) sampled 745 sites of 155 duodenoscopes. Ten different duodenoscope types from three distinct manufacturers were sampled including 69 (46%) Olympus TJF-Q180V, 43 (29%) Olympus TJF-160VR, 11 (7%) Pentax ED34-i10T, 8 (5%) Pentax ED-3490TK and 5 (3%) Fujifilm ED-530XT8. Thirty-three (22%) duodenoscopes from 26 (39%) centres were contaminated (AM20). On 23 (15%) duodenoscopes MGO were detected, including Enterobacter cloacae, Escherichia coli, Klebsiella pneumonia and yeasts. For both definitions, contamination was not duodenoscope type dependent (p values: 0.20 and higher). CONCLUSION: In 39% of all Dutch ERCP centres, at least one AM20-contaminated patient-ready duodenoscope was identified. Fifteen per cent of the duodenoscopes harboured MGO, indicating residual organic material of previous patients, that is, failing of disinfection. These results suggest that the present reprocessing and process control procedures are not adequate and safe.

来源:Gut,查看原文。版权归原作者所有。

引用

  1. Rauwers AW, Voor In 't Holt AF, Buijs JG, et al. High prevalence rate of digestive tract bacteria in duodenoscopes: a nationwide study. Gut. 2018. PMID: 29636382. doi:10.1136/gutjnl-2017-315082

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。