高清结肠镜与Endocuff、EndoRings及全光谱内镜在结肠镜检查中腺瘤检出率的比较:一项多中心随机试验

High-definition colonoscopy versus Endocuff versus EndoRings versus full-spectrum endoscopy for adenoma detection at colonoscopy: a multicenter randomized trial.
PubMed 文献 · Gastrointest Endosc · 2018-03-09

这项3中心前瞻性随机试验纳入1188例年龄≥50岁、有常规指征且结肠完整的患者,比较单独高清前视结肠镜、高清加Endocuff、高清加EndoRings与全光谱内镜(FUSE)系统的腺瘤检出。主要终点为每次结肠镜检查的腺瘤数(APC)。结果显示Endocuff、EndoRings和标准高清结肠镜的APC均高于FUSE,Endocuff的APC高于标准高清结肠镜;FUSE和EndoRings的平均盲肠插入时间均长于Endocuff。

要点

  • 在高水平检出者中,前视高清设备优于FUSE系统,提示图像分辨率胜过视角。
  • Endocuff的APC高于标准高清结肠镜(P=.014),且优于EndoRings和无黏膜暴露装置。
  • FUSE和EndoRings的平均盲肠插入时间均长于Endocuff。

核心结论

  • 对于结肠镜检查的高水平检出者,前视高清设备优于FUSE系统,提示对这些检查者而言图像分辨率胜过视角。
  • Endocuff优于EndoRings以及前视高清结肠镜上的无黏膜暴露装置。

研究设计与样本

  • 3中心前瞻性随机试验,比较单独高清前视结肠镜、高清加Endocuff、高清加EndoRings与全光谱内镜(FUSE)系统。
  • 患者年龄≥50岁,有常规指征且结肠完整;研究中的结肠镜操作者均为证实的高水平检出者。
  • 主要终点为每次结肠镜检查的腺瘤数(APC)。

主要发现

  • 完成研究的1188例患者中,Endocuff组APC均值±标准差为1.82±2.58,EndoRings组为1.55±2.42,标准高清结肠镜组为1.53±2.33,均高于FUSE组的1.30±1.96(APC的P<.001)。
  • Endocuff组APC高于标准高清结肠镜组(P=.014)。
  • FUSE组平均盲肠插入时间为468±311秒,EndoRings组为403±263秒,均长于Endocuff组的354±216秒(P分别为.006和.018)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Devices used to improve polyp detection during colonoscopy have seldom been compared with each other. METHODS: We performed a 3-center prospective randomized trial comparing high-definition (HD) forward-viewing colonoscopy alone to HD with Endocuff to HD with EndoRings to the full spectrum endoscopy (FUSE) system. Patients were age ≥50 years and had routine indications and intact colons. The study colonoscopists were all proven high-level detectors. The primary endpoint was adenomas per colonoscopy (APC). RESULTS: Among 1188 patients who completed the study, APC with Endocuff (APC mean ± standard deviation: 1.82 ± 2.58), EndoRings (1.55 ± 2.42), and standard HD colonoscopy (1.53 ± 2.33) were all higher than FUSE (1.30 ± 1.96; P < .001 for APC). The APC for Endocuff was higher than standard HD colonoscopy (P = .014). Mean cecal insertion times with FUSE (468 ± 311 seconds) and EndoRings (403 ± 263 seconds) were both longer than with Endocuff (354 ± 216 seconds; P = .006 and .018, respectively). CONCLUSIONS: For high-level detectors at colonoscopy, forward-viewing HD instruments dominate the FUSE system, indicating that for these examiners image resolution trumps angle of view. Further, Endocuff is a dominant strategy over EndoRings and no mucosal exposure device on a forward-viewing HD colonoscope. (Clinical trial registration number: NCT02345889.).