优化十二指肠镜再处理:对培养与隔离方案的严格评估
本研究基于美国一家高流量内镜中心2014至2017年前瞻性质量保证数据库,分析4307次十二指肠镜培养结果,评估培养与隔离方案的长期效果。高关注微生物分离率为0.697%,停用高频培养阳性镜A及实施新清洁方案后阳性率下降,停用镜B及强制设备改装无影响。
要点
- 停用高频培养阳性十二指肠镜并优化手工清洁可降低高水平消毒缺陷率。
- 严格的培养与隔离方案有助于识别问题内镜。
- 仍需廉价可靠的方法评估再处理充分性。
核心结论
- 停用培养阳性率高的十二指肠镜并优化手工清洁实践有助于高水平消毒缺陷率整体下降。
- 严格的培养与隔离方案允许识别问题内镜。
- 鉴于这些任务固有的复杂性,仍非常需要一种廉价且高度可靠的方法来检查再处理的充分性。
研究设计与样本
- 回顾性分析美国一家高流量内镜中心2014至2017年初始3年培养与隔离期间前瞻性收集的所有十二指肠镜培养(n=4307)的质量保证数据库。
- 所有十二指肠镜均经过手工清洁和自动再处理与干燥,然后使用美国疾病控制与预防中心开发的修改方案进行采样,每使用一次即培养。
主要发现
- 研究期间共获得4307次十二指肠镜培养,其中33次分离出高关注微生物,高水平消毒缺陷率为0.697%。
- 停用高频培养阳性十二指肠镜A以及实施新的制造商推荐清洁方案是具有统计学意义的干预措施。
- 停用第二台高频培养阳性十二指肠镜B和强制设备改装对观察到的十二指肠镜培养阳性率无影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Iatrogenic infections related to duodenoscopes remain a top concern for medical centers where ERCP is performed. We assessed the long-term results and impact of key interventions in the optimization of a rigorous "culture and quarantine" program for duodenoscope reprocessing. METHODS: We reviewed a prospectively collected, quality assurance database of all duodenoscope cultures (n = 4307) obtained for the initial 3-year duration of culture and quarantine from 2014 to 2017 in a single U.S.-based, high-volume endoscopy center. All duodenoscopes were subject to manual cleaning and automated reprocessing and drying, followed by sampling using a modified protocol developed by the Centers for Disease Control and Prevention. Duodenoscopes were cultured per-use. RESULTS: A total of 4307 duodenoscope cultures were obtained during the study period. High-concern organisms were isolated from 33 of these cultures, resulting in a .697% high-level disinfection defect rate. Statistically significant interventions included withdrawal of a high-frequency culture-positive duodenoscope (scope A) from clinical service in addition to implementation of new manufacturer-recommended cleaning protocols. Withdrawal of a second high-frequency culture-positive duodenoscope (scope B) and a mandatory device retrofit had no effect on the observed rate of positive duodenoscope cultures. CONCLUSIONS: Withdrawal of duodenoscopes with a high rate of culture positivity and optimizing manual cleaning practices have contributed to an overall decline in the high-level disinfection defect rate. A stringent culture and quarantine protocol allowed identification of the culprit endoscopes. There remains a much-needed role for an inexpensive and highly reliable method to check on the adequacy of reprocessing given the inherent complexity of these tasks.
引用
- Higa JT, Choe J, Tombs D, et al. Optimizing duodenoscope reprocessing: rigorous assessment of a culture and quarantine protocol. Gastrointest Endosc. 2018. PMID: 29476846. doi:10.1016/j.gie.2018.02.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。