文献速递消化内镜消化道肿瘤与早癌

磁锚定引导内镜黏膜下剥离术治疗胃病变(附视频)

Magnetic anchor-guided endoscopic submucosal dissection for gastric lesions (with video).
PubMed 文献 · Gastrointest Endosc · 2018-01-17

这项前瞻性试验在Yamashita医院对50处胃病变行磁锚定引导内镜黏膜下剥离术(MAG-ESD),使用绝缘头电刀和钕磁铁锚定装置。所有病变均成功完成MAG-ESD,整块切除率和完整整块切除率均为100%,无不良事件,磁锚定装置均可回收。

要点

  • MAG-ESD在50处胃病变中全部成功实施,整块切除和完整整块切除均确认。
  • 磁锚定装置附着中位时间6分钟,手术中位时间49分钟,锚定装置全部回收。
  • 所有病例无不良事件,作者希望该技术有助于困难病变的切除。

核心结论

  • 本研究明确证明了MAG-ESD在胃部应用的可行性,作者希望该技术有助于困难病变的切除。

研究设计与样本

  • 前瞻性试验,在Yamashita医院对50处胃病变使用绝缘头电刀行MAG-ESD。

主要发现

  • 50例患者(病变中位大小20 mm,范围5-100 mm)入组,所有50处胃病变均成功完成MAG-ESD。
  • 使用外部磁铁获得了充分的反牵引,所有病例均实现整块切除并确认完整整块切除,无不良事件。
  • 磁锚定装置附着中位时间6分钟(范围2-14),手术中位时间49分钟(范围15-301),磁锚定装置在所有病例中均可回收。

关键数值与推荐

  • 磁锚定装置由连接3-0丝线的止血夹上的内部钕磁铁构成,外部和内部磁铁均由钕磁铁制成。

临床怎么用

  • 原文未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: The feasibility of magnetic anchor-guided endoscopic submucosal dissection (MAG-ESD) using a neodymium magnet for gastric lesions has not been clarified. The aim of study was to evaluate the feasibility of MAG-ESD using neodymium magnets while treating gastric lesions. METHODS: This prospective trial was conducted at the Yamashita Hospital. MAG-ESD was performed for 50 gastric lesions using an insulated-tip knife. The magnetic anchor consisted of an internal neodymium magnet attached to a hemoclip with 3-0 silk. The external and internal magnets were made from the neodymium magnet. The feasibility of traction using MAG-ESD, en bloc resection rate, complete en bloc resection rate, time required for preparation and attaching the magnetic anchor, procedure time, rate of retrieval of the magnetic anchors, and adverse events were evaluated. RESULTS: Fifty patients (median lesion size, 20 mm [range, 5-100]) were enrolled. MAG-ESDs were successfully performed for all 50 gastric lesions. Adequate counter-traction was obtained using the external magnet. En bloc resections were achieved and complete en bloc resections confirmed in all cases without adverse events. Attaching the magnetic anchor required a median of 6 minutes (range, 2-14). The median procedure time was 49 minutes (range, 15-301), and the magnetic anchors could be retrieved in all cases. CONCLUSIONS: This study clearly demonstrated the feasibility of this MAG-ESD in the stomach. We hope this procedure will facilitate the resection of difficult lesions. (Clinical trial registration number: UMIN000024100.).

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Matsuzaki I, Hattori M, Hirose K, et al. Magnetic anchor-guided endoscopic submucosal dissection for gastric lesions (with video). Gastrointest Endosc. 2018. PMID: 29352971. doi:10.1016/j.gie.2018.01.015