计算机辅助诊断在放大窄带成像中识别和勾画早期胃癌的研究
本研究开发了一套计算机辅助诊断系统,用于在放大窄带成像(M-NBI)图像中识别和勾画早期胃癌(EGC)。采用回顾性收集的M-NBI图像构建训练集和测试集,基于灰度共生矩阵特征训练支持向量机。测试集识别准确率96.3%、精确率98.3%、召回率96.7%、特异性95%,勾画区域一致性准确率73.8%±10.9%。结论认为该试点研究显示系统在实时诊断和勾画EGC方面具有很大潜力。
要点
- 测试集识别EGC的准确率96.3%、精确率98.3%、召回率96.7%、特异性95%。
- 勾画癌性区块与专家勾画区域的一致性准确率73.8%±10.9%。
- 每张图像识别耗时0.41±0.01秒,勾画耗时0.49±0.04秒。
核心结论
- 这项试点研究表明,该计算机辅助诊断系统在M-NBI图像中实时诊断和勾画早期胃癌方面具有很大潜力。
研究设计与样本
- 回顾性收集并随机选取66张EGC的M-NBI图像和60张非癌M-NBI图像作为训练集,61张EGC的M-NBI图像和20张非癌M-NBI图像作为测试集。
主要发现
- 测试集诊断性能:准确率96.3%,精确率(阳性预测值)98.3%,召回率(灵敏度)96.7%,特异性95%,每张图像耗时0.41±0.01秒。
- 基于区块的区域一致性性能:准确率73.8%±10.9%,精确率(阳性预测值)75.3%±20.9%,召回率(灵敏度)65.5%±19.9%,特异性80.8%±17.1%,每张图像耗时0.49±0.04秒。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Magnifying narrow-band imaging (M-NBI) is important in the diagnosis of early gastric cancers (EGCs) but requires expertise to master. We developed a computer-aided diagnosis (CADx) system to assist endoscopists in identifying and delineating EGCs. METHODS: We retrospectively collected and randomly selected 66 EGC M-NBI images and 60 non-cancer M-NBI images into a training set and 61 EGC M-NBI images and 20 non-cancer M-NBI images into a test set. After preprocessing and partition, we determined 8 gray-level co-occurrence matrix (GLCM) features for each partitioned 40 × 40 pixel block and calculated a coefficient of variation of 8 GLCM feature vectors. We then trained a support vector machine (SVMLv1) based on variation vectors from the training set and examined in the test set. Furthermore, we collected 2 determined P and Q GLCM feature vectors from cancerous image blocks containing irregular microvessels from the training set, and we trained another SVM (SVMLv2) to delineate cancerous blocks, which were compared with expert-delineated areas for area concordance. RESULTS: The diagnostic performance revealed accuracy of 96.3%, precision (positive predictive value [PPV]) of 98.3%, recall (sensitivity) of 96.7%, and specificity of 95%, at a rate of 0.41 ± 0.01 seconds per image. The performance of area concordance, on a block basis, demonstrated accuracy of 73.8% ± 10.9%, precision (PPV) of 75.3% ± 20.9%, recall (sensitivity) of 65.5% ± 19.9%, and specificity of 80.8% ± 17.1%, at a rate of 0.49 ± 0.04 seconds per image. CONCLUSIONS: This pilot study demonstrates that our CADx system has great potential in real-time diagnosis and delineation of EGCs in M-NBI images.
引用
- Kanesaka T, Lee TC, Uedo N, et al. Computer-aided diagnosis for identifying and delineating early gastric cancers in magnifying narrow-band imaging. Gastrointest Endosc. 2017. PMID: 29225083. doi:10.1016/j.gie.2017.11.029