一种用于改善肠道准备不充分结肠可视化效果的新型装置
在35头接受减少肠道准备的约克郡杂交猪中,4名经验丰富的消化内科医生使用Pure-Vu系统进行术中清洗;基线时14%的猪结肠准备充分(中位BBPS=0),使用后改善至100%(中位BBPS=3,P<.001),未观察到不良效应,医生认为操作简便直观。
要点
- 基线时仅14%的猪结肠准备充分,使用Pure-Vu后改善至100%(P<.001)。
- 中位BBPS评分从0(四分位距=1)提升至3(四分位距=0)。
- 未观察到不良效应,无失败或提前终止的病例,医生认为操作简便直观。
核心结论
- Pure-Vu系统能有效清洁肠道准备不充分的猪结肠,且操作简便。
- 作者认为,在临床实践中应用Pure-Vu装置可能改善整体肠道准备质量,并减少因肠道准备不充分而导致的重复检查。
研究设计与样本
- 在35头约克郡杂交猪(66%雌性)中,由4名经验丰富的消化内科医生使用Pure-Vu系统,这些猪接受了减少的肠道准备以确保基线时肠道准备不充分。
- 结肠镜插入过程中评估基线肠道准备,随后使用Pure-Vu系统清洁结肠并再次评估肠道准备。
主要发现
- 未观察到不良效应,无失败或提前终止的病例。
- 基线时14%的猪结肠准备充分(中位BBPS评分=0,第25百分位=0,第75百分位=1,四分位距=1)。
- 使用Pure-Vu后100%的猪结肠准备充分(Wilcoxon符号秩检验P<.001)(中位BBPS评分=3,第25百分位=3,第75百分位=3,四分位距=0)。
- 医生认为Pure-Vu操作简便且直观。
临床怎么用
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Adequate bowel preparation is crucial for a quality colonoscopy. Poor bowel preparation can result in longer procedural times, missed adenomas, earlier repeat procedures, increase costs, and decreased patient satisfaction. Pure-Vu (MOTUS GI, Tirat Carmel, Israel) is a system that facilitates intraprocedural cleaning of a poorly prepared colon during a colonoscopy by irrigating the colon and evacuating the fluid and feces. The study aims were to evaluate Pure-Vu's cleansing capabilities and its usability and safety in a live animal colon. METHODS: The Pure-Vu system was used by 4 experienced gastroenterologists in 35 Yorkshire cross swine (66% female) that received a reduced bowel preparation to ensure an inadequate bowel preparation at baseline. Before colonoscopy the Pure-Vu was attached to the colonoscope, and the baseline prep was assessed during insertion. The Pure-Vu system was then used to cleanse the colon and the prep then assessed after Pure-Vu use. RESULTS: No adverse effects and no failed or prematurely terminated cases were noted. Fourteen percent of the swine colons were adequately prepped at baseline (median Boston Bowel Preparation Scale [BBPS] score = 0 [25th percentile = 0; 75th percentile = 1; interquartile range = 1]) and improved to 100% after use of Pure-Vu (Wilcoxon signed rank test P < .001) (median BBPS score = 3 [25th percentile = 3; 75th percentile = 3; interquartile range = 0]). The physicians found Pure-Vu easy and intuitive to operate. CONCLUSIONS: The Pure-Vu system effectively cleaned inadequately prepped swine colons and proved to be easy to use. The Pure-Vu device, applied in clinical practice, may result in improved overall prep quality and a reduction in repeat examinations because of inadequately prepped colons.
引用
- Gross SA, Gerson LB, Lewis BS, et al. A novel device for improving visualization in an inadequately prepared colon. Gastrointest Endosc. 2017. PMID: 29108983. doi:10.1016/j.gie.2017.10.028
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。