计算机断层结肠成像与结肠镜检查在结直肠癌术后监测中的比较
这项前瞻性研究纳入5个三级学术中心231例切除的0-III期结直肠癌患者,术后约1年行CT结肠成像(CTC)加CT,同日行光学结肠镜(OC)。CTC检测≥6mm息肉的患者灵敏度44.0%、特异度93.4%,检测≥10mm息肉灵敏度76.9%、特异度89.0%;结论为CTC在检出≥6mm息肉患者方面劣于OC。
要点
- CTC检测≥6mm息肉灵敏度44.0%(95%CI 30.2-57.8)、特异度93.4%(95%CI 89.7-97.0)。
- CTC检测≥10mm息肉灵敏度76.9%(95%CI 54.0-99.8)、特异度89.0%(95%CI 84.8-93.1)。
- CTC对≥10mm腺瘤的阴性预测值为98.6%(95%CI 97.0-100)。
核心结论
- 在结直肠癌切除术后1年的监测人群中,CTC在检出≥6mm息肉患者方面劣于OC。
研究设计与样本
- 前瞻性研究,纳入5个三级学术中心231例切除的0-III期结直肠癌患者,术后约1年行CTC加CT后同日行OC。
主要发现
- 231例中116例(50.2%)经OC检出任何大小或组织学类型的息肉,15.6%检出传统腺瘤和/或≥6mm锯齿状息肉。
- 未检出腔内癌。
- CTC检测≥6mm息肉患者的灵敏度44.0%(95%CI 30.2-57.8)、特异度93.4%(95%CI 89.7-97.0)。
- CTC检测≥10mm息肉的灵敏度76.9%(95%CI 54.0-99.8)、特异度89.0%(95%CI 84.8-93.1)。
- 仅考虑腺瘤性息肉时结果相似;CTC对≥6mm腺瘤的阴性预测值90.7%(95%CI 86.7-94.5),对≥10mm腺瘤的阴性预测值98.6%(95%CI 97.0-100)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND & AIMS: Recommendations for surveillance after curative surgery for colorectal cancer (CRC) include a 1-year post-resection abdominal-pelvic computed tomography (CT) scan and optical colonoscopy (OC). CT colonography (CTC), when used in CRC screening, effectively identifies colorectal polyps ≥10 mm and cancers. We performed a prospective study to determine whether CTC, concurrent with CT, could substitute for OC in CRC surveillance. METHODS: Our study enrolled 231 patients with resected stage 0-III CRC, identified at 5 tertiary care academic centers. Approximately 1 year after surgery, participants underwent outpatient CTC plus CT, followed by same-day OC. CTC results were revealed after endoscopic visualization of sequential colonic segments, which were re-examined for discordant findings. The primary outcome was performance of CTC in the detection of colorectal adenomas and cancers using endoscopy as the reference standard. RESULTS: Of the 231 participants, 116 (50.2%) had polyps of any size or histology identified by OC, and 15.6% had conventional adenomas and/or serrated polyps ≥6 mm. No intra-luminal cancers were detected. CTC detected patients with polyps of ≥6 mm with 44.0% sensitivity (95% CI, 30.2-57.8) and 93.4% specificity (95% CI, 89.7-97.0). CTC detected polyps ≥10 mm with 76.9% sensitivity (95% CI, 54.0-99.8) and 89.0% specificity (95% CI, 84.8-93.1). Similar values were found when only adenomatous polyps were considered. The negative predictive value of CTC for adenomas ≥6 mm was 90.7% (95% CI, 86.7-94.5) and for adenomas ≥10 mm the negative predictive value was 98.6% (95% CI, 97.0-100). CONCLUSIONS: In a CRC surveillance population 1 year following resection, CTC was inferior to OC for detecting patients with polyps ≥6 mm. Clinical Trials.gov Registration Number: NCT02143115.
引用
- Weinberg DS, Pickhardt PJ, Bruining DH, et al. Computed Tomography Colonography vs Colonoscopy for Colorectal Cancer Surveillance After Surgery. Gastroenterology. 2017. PMID: 29174927. doi:10.1053/j.gastro.2017.11.025
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。