使用深度学习模型在标准结肠镜原始视频分析中实时鉴别微小结直肠腺瘤与增生性息肉
研究开发了基于深度卷积神经网络的人工智能模型,使用窄带成像视频帧在常规结肠镜原始视频上训练和验证,并在125个连续遇到的微小息肉视频上测试。模型对106个息肉进行预测,准确率94%(95%CI 86%至97%),腺瘤识别灵敏度98%(95%CI 92%至100%),特异度83%(95%CI 67%至93%)。
要点
- AI模型在测试集中对106个微小息肉预测的准确率为94%(95%CI 86%至97%)。
- 腺瘤识别灵敏度98%(95%CI 92%至100%),特异度83%(95%CI 67%至93%)。
- 模型对19个息肉(占测试集15%)未产生足够置信度进行组织学预测。
核心结论
- 在结肠镜视频上训练的人工智能模型能以高准确率鉴别微小腺瘤与增生性息肉。
- 计划在活体患者临床试验中进一步研究该程序以探讨「切除并丢弃」策略。
研究设计与样本
- 开发基于深度卷积神经网络的人工智能模型,用于实时评估结肠镜视频图像中的结直肠息肉。
- 仅使用窄带成像视频帧,并在相关多类别间均等分配。
- 使用常规检查中未针对人工智能分类专门设计或调整的原始视频训练和验证模型。
- 在另一系列125个连续遇到的、经证实为腺瘤或增生性息肉的微小息肉视频上测试模型。
主要发现
- 人工智能模型采用置信度机制,对测试集中19个息肉(占15%)未产生足够置信度预测组织学。
- 对剩余106个微小息肉,模型准确率为94%(95%CI 86%至97%)。
- 腺瘤识别灵敏度为98%(95%CI 92%至100%),特异度为83%(95%CI 67%至93%)。
- 阴性预测值为97%,阳性预测值为90%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 模型对测试集中19个息肉(占15%)未产生足够置信度预测组织学。
- 原文报告计划在活体患者临床试验中进一步研究该程序以探讨「切除并丢弃」策略。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In general, academic but not community endoscopists have demonstrated adequate endoscopic differentiation accuracy to make the 'resect and discard' paradigm for diminutive colorectal polyps workable. Computer analysis of video could potentially eliminate the obstacle of interobserver variability in endoscopic polyp interpretation and enable widespread acceptance of 'resect and discard'. STUDY DESIGN AND METHODS: We developed an artificial intelligence (AI) model for real-time assessment of endoscopic video images of colorectal polyps. A deep convolutional neural network model was used. Only narrow band imaging video frames were used, split equally between relevant multiclasses. Unaltered videos from routine exams not specifically designed or adapted for AI classification were used to train and validate the model. The model was tested on a separate series of 125 videos of consecutively encountered diminutive polyps that were proven to be adenomas or hyperplastic polyps. RESULTS: The AI model works with a confidence mechanism and did not generate sufficient confidence to predict the histology of 19 polyps in the test set, representing 15% of the polyps. For the remaining 106 diminutive polyps, the accuracy of the model was 94% (95% CI 86% to 97%), the sensitivity for identification of adenomas was 98% (95% CI 92% to 100%), specificity was 83% (95% CI 67% to 93%), negative predictive value 97% and positive predictive value 90%. CONCLUSIONS: An AI model trained on endoscopic video can differentiate diminutive adenomas from hyperplastic polyps with high accuracy. Additional study of this programme in a live patient clinical trial setting to address resect and discard is planned.
引用
- Byrne MF, Chapados N, Soudan F, et al. Real-time differentiation of adenomatous and hyperplastic diminutive colorectal polyps during analysis of unaltered videos of standard colonoscopy using a deep learning model. Gut. 2017. PMID: 29066576. doi:10.1136/gutjnl-2017-314547
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。