文献速递炎症性肠病消化内镜

超声内镜指数检测溃疡性结肠炎炎症的可靠性

Reliability of EUS indices to detect inflammation in ulcerative colitis.
PubMed 文献 · Gastrointest Endosc · 2017-07-29

本研究评估现有超声内镜(EUS)指数在溃疡性结肠炎(UC)中的可靠性,并分析其与内镜及组织学评分的相关性。4名盲法超声内镜医师对58例UC患者的视频进行三次评估,充血评分与Tsuga评分的评估者内组内相关系数(ICC)分别为0.76和0.85,评估者间ICC分别为0.34和0.36,与Mayo内镜评分等内镜及组织学评分的相关性较低。经RAND共识流程制定了标准化定义并修订出EUS-UC评分。

要点

  • 充血评分与Tsuga评分的评估者内ICC分别为0.76和0.85,评估者间ICC分别为0.34和0.36。
  • 两评分与Mayo内镜评分、改良Baron评分、UCEIS及Geboes组织病理评分的相关性均较低。
  • 经RAND共识流程修订的EUS-UC评分包括肠壁增厚、炎症深度和充血三项。

核心结论

  • EUS指数在UC中的评估者内一致性为中等至几乎完全一致,但评估者间一致性为一般。
  • 标准化条目定义并开发修订的评估工具,有潜力作为UC的评估和预后工具。

研究设计与样本

  • 4名盲法超声内镜医师对58例UC患者的58段内镜和EUS视频进行三次评估。
  • 采用组内相关系数(ICC)估计充血评分和Tsuga评分的评估者内与评估者间可靠性。
  • 采用bootstrapping方法计算与Mayo内镜评分、改良Baron评分(MBS)、溃疡性结肠炎内镜严重指数(UCEIS)和Geboes组织病理评分(GHS)的相关性。
  • 通过RAND共识流程制定标准化定义并开发修订的EUS-UC评分。

主要发现

  • 充血评分评估者内ICC为0.76(95%CI 0.71-0.80),Tsuga评分评估者内ICC为0.85(95%CI 0.79-0.89)。
  • 充血评分评估者间ICC为0.34(95%CI 0.25-0.42),Tsuga评分评估者间ICC为0.36(95%CI 0.24-0.46)。
  • 充血评分与Tsuga评分分别与Mayo评分系统的相关性为0.39(95%CI 0.15-0.61)和0.28(95%CI 0.04-0.51)。
  • 充血评分与Tsuga评分分别与MBS的相关性为0.38(95%CI 0.16-0.57)和0.25(95%CI -0.01-0.48)。
  • 充血评分与Tsuga评分分别与UCEIS的相关性为0.41(95%CI 0.16-0.62)和0.27(95%CI 0.01-0.50)。

关键数值与推荐

  • 修订的EUS-UC评分包括肠壁增厚、炎症深度和充血。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: EUS is a potentially useful modality to assess severity of inflammation in ulcerative colitis (UC). We assessed the reliability of existing EUS indices and correlated them with endoscopic and histologic scores. METHODS: Four blinded endosonographers assessed 58 endoscopic and EUS videos in triplicate, from patients with UC. Intrarater and interrater reliability of the hyperemia and Tsuga scores were estimated by using intra-class correlation coefficients (ICCs). Correlation with the Mayo endoscopy score, modified Baron score (MBS), Ulcerative Colitis Endoscopic Index of Severity (UCEIS), and Geboes histopathology score (GHS) were calculated by using bootstrapping methods. A RAND consensus process led to development of standardized definitions and a revised EUS-UC score. RESULTS: ICCs for intrarater reliability were 0.76 (95% confidence interval [CI], 0.71-0.80) for the hyperemia score and 0.85 (95% CI, 0.79-0.89) for the Tsuga score. Corresponding values for interrater reliability were 0.34 (95% CI, 0.25-0.42) and 0.36 (95% CI, 0.24-0.46). Correlation between hyperemia and Tsuga scores to Mayo scoring system, MBS, UCEIS, and the GHS were 0.39 (95% CI, 0.15-0.61) and 0.28 (95% CI, 0.04-0.51), 0.38 (95% CI, 0.16-0.57) and 0.25 (95% CI, -0.01-0.48), 0.41 (95% CI, 0.16-0.62) and 0.27 (95% CI, 0.01-0.50), 0.37 (95% CI, -0.01-0.48) and 0.24 (95% CI, 0.13-0.57), respectively. The revised EUS-UC score included bowel wall thickening, depth of inflammation, and hyperemia. CONCLUSIONS: Although substantial to almost perfect intrarater agreement existed for EUS indices in UC, interrater agreement was fair. Standardization of item definitions with development of a revised evaluative instrument has potential application as an evaluative and prognostic tool for UC. (Clinical trial registration number: NCT01852760.).

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Yan B, Feagan B, Teriaky A, et al. Reliability of EUS indices to detect inflammation in ulcerative colitis. Gastrointest Endosc. 2017. PMID: 28760533. doi:10.1016/j.gie.2017.07.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。