文献速递胰腺与胆道疾病消化内镜

超声内镜与磁共振胰胆管成像检测胆总管结石诊断准确性的头对头研究Meta分析

Diagnostic accuracy of EUS compared with MRCP in detecting choledocholithiasis: a meta-analysis of diagnostic test accuracy in head-to-head studies.
PubMed 文献 · Gastrointest Endosc · 2017-06-20

该Meta分析纳入5项前瞻性队列研究,头对头比较超声内镜(EUS)与磁共振胰胆管成像(MRCP)检测胆总管结石的诊断准确性。EUS汇总敏感度0.97、特异度0.90,MRCP分别为0.87和0.92;EUS诊断比值比显著高于MRCP(162.5 vs 79.0,P=0.008),主要源于EUS敏感度显著更高(P=0.006),两者特异度无显著差异(P=0.42)。

要点

  • EUS检测胆总管结石的汇总敏感度0.97、特异度0.90。
  • MRCP检测胆总管结石的汇总敏感度0.87、特异度0.92。
  • EUS诊断比值比显著高于MRCP(162.5 vs 79.0,P=0.008),特异度无显著差异(P=0.42)。

核心结论

  • EUS和MRCP均提供良好的诊断准确性,EUS具有统计学上更好的诊断准确性和敏感度,特异度相当。
  • 作者认为在怀疑胆总管结石的患者中,适当时应将EUS纳入诊断流程。

研究设计与样本

  • 研究为诊断准确性Meta分析,采用Cochrane协作网推荐的方法学。
  • 两位评价者检索截至2017年1月的电子文献,纳入比较EUS和MRCP与参考标准的前瞻性队列研究。
  • 可接受的参考标准为ERCP、术中胆道造影或阴性病例临床随访超过3个月。
  • 共纳入32项研究中的5项,采用QUADAS-2工具评价质量,未发现高偏倚风险研究。
  • 采用双变量分层模型进行诊断准确性Meta分析,构建汇总受试者工作特征曲线并计算曲线下面积。

主要发现

  • EUS汇总敏感度0.97(范围0.91-0.99),汇总特异度0.90(范围0.83-0.94)。
  • MRCP汇总敏感度0.87(范围0.80-0.93),汇总特异度0.92(范围0.87-0.96)。
  • EUS总体诊断比值比显著高于MRCP(162.5 vs 79.0,P=0.008)。
  • 进一步分析显示该差异主要源于EUS敏感度显著高于MRCP(P=0.006)。
  • 两种方法特异度无显著差异(P=0.42)。

关键数值与推荐

  • 纳入标准为比较EUS和MRCP与参考标准的前瞻性队列研究。
  • 参考标准为ERCP、术中胆道造影或阴性病例临床随访超过3个月。
  • 质量评价采用QUADAS-2工具,未报告高偏倚风险研究。

临床怎么用

  • 作者认为在怀疑胆总管结石的患者中,适当时应将EUS纳入诊断流程。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: There is a wide range of reported sensitivity and specificity for EUS and MRCP in the diagnosis of choledocholithiasis, with lack of a proper meta-analysis of diagnostic test accuracy by using head-to-head comparison. Here, we aimed to compare the diagnostic accuracy of EUS and MRCP in detecting choledocholithiasis by using appropriate methodology recommended by the Cochrane Collaboration. METHODS: A comprehensive electronic literature search up to January 2017 was done by 2 reviewers for prospective cohort studies comparing EUS and MRCP to a reference standard for detecting choledocholithiasis. The acceptable reference standards were considered ERCP, intraoperative cholangiography, or clinical follow-up >3 months for negative cases. Quality of the included studies was measured by using the QUADAS-2 tool. A bivariate hierarchical model was used to perform the meta-analysis of diagnostic test accuracy. Summary receiver operating characteristics were developed and the area under the curve was calculated. RESULTS: A total of 5 of 32 studies were included. No study presented a high risk of bias. The pooled sensitivity and specificity were 0.97 (range, 0.91-0.99) and 0.90 (range, 0.83-0.94) for EUS and 0.87 (range, 0.80-0.93) and 0.92 (range, 0.87-0.96) for MRCP. The overall diagnostic odds ratio of EUS was significantly higher than the one with MRCP (162.5 vs 79.0, respectively; P = .008). Further analysis showed that this was mainly due to the significantly higher sensitivity of EUS as compared with that of MRCP (P = .006). The specificity was not significantly different between 2 modalities (P = .42). CONCLUSION: Both EUS and MRCP provide good diagnostic accuracy, with EUS providing statically better diagnostic accuracy and sensitivity, with comparable specificity. EUS should be incorporated in the diagnostic algorithm in patients suspected of choledocholithiasis whenever appropriate.

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Meeralam Y, Al-Shammari K, Yaghoobi M, et al. Diagnostic accuracy of EUS compared with MRCP in detecting choledocholithiasis: a meta-analysis of diagnostic test accuracy in head-to-head studies. Gastrointest Endosc. 2017. PMID: 28645544. doi:10.1016/j.gie.2017.06.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。