文献速递炎症性肠病消化内镜

肛瘘型克罗恩病磁共振成像指数的开发

The development of a magnetic resonance imaging index for fistulising Crohn's disease.
PubMed 文献 · Aliment Pharmacol Ther · 2017-06-27

本研究评估Van Assche肛瘘磁共振成像(MRI)指数的信度,并通过共识流程制定评分规范和新条目,由四名放射科医生对50例MRI图像随机顺序评估三次。原版与改良版Van Assche指数及VAS的评估者内信度ICC分别为0.86、0.90和0.86,评估者间信度ICC分别为0.66、0.67和0.58。研究创建了包含七个条目、范围0-24的改良Van Assche指数。

要点

  • Van Assche指数评估者内信度ICC为0.86(0.81-0.90),评估者间信度ICC为0.66(0.52-0.76)。
  • 改良Van Assche指数评估者内信度ICC为0.90(0.86-0.93),评估者间信度ICC为0.67(0.55-0.75)。
  • 改良Van Assche指数包含七个条目,范围0-24。

核心结论

  • 使用Van Assche指数评估肛瘘型克罗恩病MRI图像时,评估者内信度为「几乎完美」,但评估者间信度显著较低。
  • 作者认为对Van Assche指数的改良应能形成更优的评估工具。

研究设计与样本

  • 通过共识流程为现有Van Assche指数组分条目和新条目制定评分规范。
  • 四名经验丰富的放射科医生在三个场合以随机顺序评估50例MRI图像。
  • 采用混合效应模型,以100 mm视觉模拟量表(VAS)作为整体严重度结局、组分条目作为预测因子,创建改良Van Assche指数。

主要发现

  • 原版Van Assche指数、改良Van Assche指数和VAS的评估者内信度ICC(95%CI)分别为0.86(0.81-0.90)、0.90(0.86-0.93)和0.86(0.82-0.89)。
  • 原版Van Assche指数、改良Van Assche指数和VAS的评估者间信度ICC(95%CI)分别为0.66(0.52-0.76)、0.67(0.55-0.75)和0.58(0.47-0.66)。
  • 分歧来源包括瘘管数量、位置和延伸范围以及直肠壁受累。
  • 创建的改良Van Assche指数包含七个组分条目,范围0-24。

关键数值与推荐

  • 原版Van Assche指数评估者内信度ICC为0.86(95%CI 0.81-0.90),评估者间信度ICC为0.66(95%CI 0.52-0.76)。
  • 改良Van Assche指数评估者内信度ICC为0.90(95%CI 0.86-0.93),评估者间信度ICC为0.67(95%CI 0.55-0.75)。
  • VAS评估者内信度ICC为0.86(95%CI 0.82-0.89),评估者间信度ICC为0.58(95%CI 0.47-0.66)。
  • 改良Van Assche指数包含七个组分条目,评分范围0-24。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Magnetic resonance imaging (MRI) is the gold standard for assessment of perianal fistulising Crohn's disease (CD). The Van Assche index is the most commonly used MRI fistula index. AIMS: To assess the reliability of the Van Assche index, and to modify the instrument to improve reliability and create a novel index for fistulising CD. METHODS: A consensus process developed scoring conventions for existing Van Assche index component items and new items. Four experienced radiologists evaluated 50 MRI images in random order on three occasions. Reliability was assessed by estimates of intraclass correlation coefficients (ICCs). Common sources of disagreement were identified and recommendations made to minimise disagreement. A mixed effects model used a 100 mm visual anologue scale (VAS) for global severity as outcome and component items as predictors to create a modified Van Assche index. RESULTS: Intraclass correlation coefficients (95% confidence intervals) for intra-rater reliability of the original and modified Van Assche indices and the VAS were 0.86 (0.81-0.90), 0.90 (0.86-0.93) and 0.86 (0.82-0.89). Corresponding ICCs for inter-rater reliability were 0.66 (0.52-0.76), 0.67 (0.55-0.75) and 0.58 (0.47-0.66). Sources of disagreement included number, location, and extension of fistula tracts, and rectal wall involvement. A modified Van Assche index (range 0-24) was created that included seven component items. CONCLUSIONS: Although "almost perfect" intra-rater reliability was observed for the assessment of MRI images for fistulising CD using the Van Assche index, inter-rater reliability was considerably lower. Our modification of this index should result in a more optimal instrument.

来源:Aliment Pharmacol Ther,查看原文。版权归原作者所有。

引用

  1. Samaan MA, Puylaert CAJ, Levesque BG, et al. The development of a magnetic resonance imaging index for fistulising Crohn's disease. Aliment Pharmacol Ther. 2017. PMID: 28653753. doi:10.1111/apt.14190

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。