磁共振弹性成像测量的剪切硬度作为儿童非酒精性脂肪性肝病纤维化生物标志物
该前瞻性多中心研究在90例非酒精性脂肪性肝病患儿中评估二维磁共振弹性成像检测纤维化和进展性纤维化的准确性,并比较手动与自动分析方法的一致性;各方法测得的硬度值与纤维化分期显著相关,检测任何纤维化的交叉验证准确性为72.2%,评估进展性纤维化的准确性各方法在86.7%至90.0%之间。
要点
- 二维磁共振弹性成像可用于评估非酒精性脂肪性肝病患儿的肝脏硬度。
- 各方法测得的硬度值与纤维化分期显著相关(ρ=0.52至0.55)。
- 检测任何纤维化的总体交叉验证准确性为72.2%。
核心结论
- 二维磁共振弹性成像可估算非酒精性脂肪性肝病患儿的肝脏硬度。
- 自动分析技术的进一步优化和验证将是标准化磁共振弹性成像的重要步骤。
- 如何最好地将磁共振弹性成像整合到儿童非酒精性脂肪性肝病评估的临床方案中,将需要前瞻性评估。
研究设计与样本
- 前瞻性、多中心研究,纳入90例非酒精性脂肪性肝病患儿,平均年龄13.1±2.4岁。
- 采用二维磁共振弹性成像,弹性图由两个阅片中心手动分析,并使用一种新的自动技术分析,每种方法独立进行。
主要发现
- 90例患儿的中位肝脏硬度为2.35 kPa。
- 两个阅片中心测得的硬度值之间强相关(r=0.83)。
- 三种分析与纤维化分期均显著相关:中心1 ρ=0.53,中心2 ρ=0.55,自动分析 ρ=0.52,P<0.001。
- 检测任何纤维化的总体交叉验证准确性为72.2%(95%CI 61.8%-81.1%)。
- 评估进展性纤维化的交叉验证准确性:中心1为88.9%(95%CI 80.5%-94.5%),中心2为90.0%(95%CI 81.9%-95.3%),自动分析为86.7%(95%CI 77.9%-92.9%)。
关键数值与推荐
- 检测任何纤维化的总体交叉验证准确性为72.2%(95%CI 61.8%-81.1%),所有方法相同。
- 评估进展性纤维化的交叉验证准确性:中心1为88.9%(95%CI 80.5%-94.5%),中心2为90.0%(95%CI 81.9%-95.3%),自动分析为86.7%(95%CI 77.9%-92.9%)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
UNLABELLED: Magnetic resonance elastography (MRE) is a promising technique for noninvasive assessment of fibrosis, a major determinant of outcome in nonalcoholic fatty liver disease (NAFLD). However, data in children are limited. The purpose of this study was to determine the accuracy of MRE for the detection of fibrosis and advanced fibrosis in children with NAFLD and to assess agreement between manual and novel automated reading methods. We performed a prospective, multicenter study of two-dimensional (2D) MRE in children with NAFLD. MR elastograms were analyzed manually at two reading centers, and using a new automated technique. Analysis using each approach was done independently. Correlations were determined between MRE analysis methods and fibrosis stage. Thresholds for classifying the presence of fibrosis and of advanced fibrosis were computed and cross-validated. In 90 children with a mean age of 13.1 ± 2.4 years, median hepatic stiffness was 2.35 kPa. Stiffness values derived by each reading center were strongly correlated with each other (r = 0.83). All three analyses were significantly correlated with fibrosis stage (center 1, ρ = 0.53; center 2, ρ = 0.55; and automated analysis, ρ = 0.52; P < 0.001). Overall cross-validated accuracy for detecting any fibrosis was 72.2% for all methods (95% confidence interval [CI], 61.8%-81.1%). Overall cross-validated accuracy for assessing advanced fibrosis was 88.9% (95% CI, 80.5%-94.5%) for center 1, 90.0% (95% CI, 81.9%-95.3%) for center 2, and 86.7% (95% CI, 77.9%-92.9%) for automated analysis. CONCLUSION: 2D MRE can estimate hepatic stiffness in children with NAFLD. Further refinement and validation of automated analysis techniques will be an important step in standardizing MRE. How to best integrate MRE into clinical protocols for the assessment of NAFLD in children will require prospective evaluation. (Hepatology 2017;66:1474-1485).
引用
- Schwimmer JB, Behling C, Angeles JE, et al. Magnetic resonance elastography measured shear stiffness as a biomarker of fibrosis in pediatric nonalcoholic fatty liver disease. Hepatology. 2017. PMID: 28493388. doi:10.1002/hep.29241
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。