文献速递肝病

使用新型室温磁化率计灵敏且无创地评估肝细胞铁

Sensitive and non-invasive assessment of hepatocellular iron using a novel room-temperature susceptometer.
PubMed 文献 · J Hepatol · 2017-05-05

前瞻性纳入264例有或无铁过载或肝病征象的患者,评估新型室温磁化率计(RTS)无创检测肝铁浓度(LIC)。RTS信号与铁浓度高度线性相关(r²=0.998),优化算法后84%病例可获得有效测量;LIC-RTS与原子吸收光谱法(r=0.74)、磁共振成像(r=0.64)及肝细胞铁(r=0.58)显著相关,重度肝铁过载(≥2级)检测的预测值、灵敏度、特异度和准确度与原子吸收光谱法相当且优于所有血清铁标志物。作者认为RTS可快速无创测量LIC,与MRI相比可能成为经济有效的床旁LIC筛查方法。

要点

  • RTS信号与铁浓度高度线性相关(r²=0.998),检测限为0.3mM。
  • 优化算法后84%病例可获得有效LIC-RTS测量,正常值为1.4mg/g干重。
  • 重度肝铁过载(≥2级)检测的预测值、灵敏度、特异度和准确度与原子吸收光谱法相当且优于所有血清铁标志物。

核心结论

  • RTS可快速、无创地测量肝铁浓度;与MRI相比,它可能成为经济有效的床旁肝铁浓度筛查方法。

研究设计与样本

  • 前瞻性纳入264例有或无铁过载或肝病征象的患者,其中35例接受肝活检行半定量铁测定(普鲁士蓝染色)、原子吸收光谱法(AAS,n=33)或磁共振成像(MRI,n=15)。

主要发现

  • 体外研究显示RTS信号与铁浓度高度线性相关(r²=0.998),检测限为0.3mM。
  • 使用考虑皮肤至肝包膜距离的优化算法后,84%的病例可获得有效测量。
  • LIC-RTS与LIC-AAS显著相关(r=0.74,p<0.001),与LIC-MRI显著相关(r=0.64,p<0.001),与肝细胞铁显著相关(r=0.58,p<0.01),但与巨噬细胞铁无显著相关(r=0.32,p=0.30)。
  • 正常LIC-RTS为1.4mg/g干重;除遗传性和输血性铁过载外,酒精性肝病患者的LIC-RTS也显著升高。
  • 肝细胞铁过载1级、2级和3级的受试者工作特征曲线下面积(AUROC)分别为0.72、0.89和0.97,对应截断值分别为2.0、4.0和5.0mg/g干重。

关键数值与推荐

  • 正常LIC-RTS为1.4mg/g干重。
  • 肝细胞铁过载1级、2级和3级的AUROC分别为0.72、0.89和0.97,截断值分别为2.0、4.0和5.0mg/g干重。

临床怎么用

  • 作者认为RTS可快速、无创地测量肝铁浓度;与MRI相比,它可能成为经济有效的床旁肝铁浓度筛查方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND & AIMS: Liver iron accumulates in various chronic liver diseases where it is an independent factor for survival and carcinogenesis. We tested a novel room-temperature susceptometer (RTS) to non-invasively assess liver iron concentration (LIC). METHODS: Two hundred and sixty-four patients with or without signs of iron overload or liver disease were prospectively enrolled. Thirty-five patients underwent liver biopsy with semiquantitative iron determination (Prussian Blue staining), atomic absorption spectroscopy (AAS, n=33), or magnetic resonance imaging (MRI, n=15). RESULTS: In vitro studies demonstrated a highly linear (r2=0.998) association between RTS-signal and iron concentration, with a detection limit of 0.3mM. Using an optimized algorithm, accounting for the skin-to-liver capsule distance, valid measurements could be obtained in 84% of cases. LIC-RTS showed a significant correlation with LIC-AAS (r=0.74, p<0.001), LIC-MRI (r=0.64, p<0.001) and hepatocellular iron (r=0.58, p<0.01), but not with macrophage iron (r=0.32, p=0.30). Normal LIC-RTS was 1.4mg/g dry weight. Besides hereditary and transfusional iron overload, LIC-RTS was also significantly elevated in patients with alcoholic liver disease. The areas under the receiver operating characteristic curve (AUROC) for grade 1, 2 and 3 hepatocellular iron overload were 0.72, 0.89 and 0.97, respectively, with cut-off values of 2.0, 4.0 and 5.0mg/g dry weight. Notably, the positive and negative predictive values, sensitivity, specificity and accuracy of severe hepatic iron overload (HIO) (grade ≥2) detection, were equal to AAS and superior to all serum iron markers. Depletion of hepatic iron could be efficiently monitored upon phlebotomy. CONCLUSIONS: RTS allows for the rapid and non-invasive measurement of LIC. In comparison to MRI, it could be a cost-effective bedside method for LIC screening. Lay summary: Novel room-temperature susceptometer (RTS) allows for the rapid, sensitive, and non-invasive measurement of liver iron concentration. In comparison to MRI, it could be a cost-effective bedside method for liver iron concentration screening.

来源:J Hepatol,查看原文。版权归原作者所有。

引用

  1. Mueller J, Raisi H, Rausch V, et al. Sensitive and non-invasive assessment of hepatocellular iron using a novel room-temperature susceptometer. J Hepatol. 2017. PMID: 28483679. doi:10.1016/j.jhep.2017.04.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。