与标准结肠镜相比,褶皱后方可视化结肠镜技术漏诊的腺瘤:3项随机背靠背串联结肠镜研究的汇总分析
该汇总分析合并3项多中心随机背靠背串联结肠镜试验共650例患者数据,评估Third Eye Retroscope、FUSE和EndoRings等褶皱后方可视化技术在不同腺瘤特征和患者亚组中降低腺瘤漏诊率的情况。结果显示这些技术显著降低近端、远端、≤5 mm、6–9 mm、无蒂、平坦、管状腺瘤及无蒂锯齿状息肉的漏诊率,但对≥10 mm、有蒂、(管状)绒毛状和进展期腺瘤无显著优势。
要点
- 褶皱后方可视化技术显著降低近端(14% vs 38%)和远端(15% vs 35%)腺瘤漏诊率(P < .001)。
- 对≤5 mm(17% vs 38%)和6–9 mm(8% vs 44%)腺瘤漏诊率显著降低(P < .001)。
- 对≥10 mm、有蒂、(管状)绒毛状和进展期腺瘤漏诊率无统计学显著差异(P > .05)。
核心结论
- 褶皱后方可视化结肠镜降低全结肠1–9 mm腺瘤的漏诊率,而对≥10 mm和进展期腺瘤未发现优势。
- 增加检出和切除<10 mm腺瘤是否降低结直肠癌发病率和死亡率仍有待确定。
- 未来研究需要确定哪种结肠镜技术对哪些患者或内镜医师最有益。
研究设计与样本
- 汇总3项多中心随机试验(NCT01044732、NCT01549535、NCT01955122)数据。
- 患者接受同日背靠背串联检查,分别使用标准结肠镜与Third Eye Retroscope、FUSE或EndoRings结肠镜。
- 共纳入650例患者(60%男性,平均年龄57.5岁,标准差9.7岁);330例先接受褶皱后方可视化结肠镜,320例先接受标准结肠镜。
主要发现
- 近端腺瘤漏诊率:褶皱后方可视化技术14% vs 标准结肠镜38%(P < .001)。
- 远端腺瘤漏诊率:15% vs 35%(P < .001)。
- ≤5 mm腺瘤漏诊率:17% vs 38%(P < .001);6–9 mm腺瘤漏诊率:8% vs 44%(P < .001)。
- 无蒂腺瘤漏诊率:16% vs 37%(P < .001);平坦腺瘤漏诊率:9% vs 52%(P = .014);管状腺瘤漏诊率:15% vs 38%(P < .001)。
- 无蒂锯齿状息肉漏诊率:7% vs 50%(P = .039);≥10 mm、有蒂、(管状)绒毛状和进展期腺瘤的漏诊率差异无统计学显著(P > .05)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 增加检出和切除<10 mm腺瘤是否降低结直肠癌发病率和死亡率仍有待确定。
- 未来研究需要确定哪种结肠镜技术对哪些患者或内镜医师最有益。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: The Third Eye Retroscope, Full Spectrum Endoscope (FUSE), and EndoRings devices have been shown to reduce overall adenoma miss rates. We evaluated the characteristics of adenomas and patient subgroups for which these behind-folds visualizing technologies mostly reduce adenoma miss rates. METHODS: Data of 3 multicenter randomized trials (NCT01044732, NCT01549535, NCT01955122) were combined. Patients underwent same-day, back-to-back tandem examinations with standard colonoscopy and Third Eye Retroscope, FUSE, or EndoRings colonoscopy, respectively. Adenoma miss rates were stratified by adenoma characteristics and patient subgroups. RESULTS: A total of 650 patients (60% male, mean age 57.5 years, standard deviation 9.7 years) were included; 330 patients underwent behind-folds visualizing colonoscopy first, and 320 patients underwent standard colonoscopy first. Regarding adenoma characteristics, adenoma miss rates were significantly (P < .001) lower with behind-folds visualizing technologies compared with standard colonoscopy for proximal (14% vs 38%) and distal (15% vs 35%), ≤5 mm (17% vs 38%), 6 to 9 mm (8% vs 44%), sessile (16% vs 37%), flat (9% vs 52%; P = .014), and tubular (15% vs 38%) adenomas and sessile serrated polyps (7% vs 50%; P = .039) but were not statistically significantly (P > .05) different for ≥10 mm, pedunculated, (tubulo-)villous, and advanced adenomas. Regarding patient subgroups, adenoma miss rates were significantly (P ≤ .020) lower with behind-folds visualizing technologies for patients ≥50 years, both sexes, and all indications. CONCLUSIONS: Behind-folds visualizing colonoscopy reduces miss rates for 1 to 9 mm adenomas in the entire colon, whereas no advantage was found for ≥10 mm and advanced adenomas. Whether increased detection and removal of <10 mm adenomas also reduces colorectal cancer incidence and mortality remains to be determined. Future research is needed to determine which colonoscopy technology would be most beneficial for which patient or endoscopist.
引用
- Brand EC, Dik VK, van Oijen MGH, et al. Missed adenomas with behind-folds visualizing colonoscopy technologies compared with standard colonoscopy: a pooled analysis of 3 randomized back-to-back tandem colonoscopy studies. Gastrointest Endosc. 2017. PMID: 28069476. doi:10.1016/j.gie.2016.12.025
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。