活检对浅表非壶腹部十二指肠腺癌术前诊断的准确性
回顾性分析95例浅表非壶腹部十二指肠上皮肿瘤(NADET)患者的内镜切除资料,将活检标本术前诊断与切除标本组织学诊断进行比较。活检诊断癌的21例中12例(57.1%)切除后为腺瘤,活检诊断腺瘤的74例中15例(20.3%)切除后为癌;活检预测最终癌诊断的敏感度为37.5%(95%CI,18.8-59.4),特异度为83.1%(95%CI,72.3-91.0),准确率为71.6%(95%CI,61.4-80.4)。作者认为十二指肠活检取样准确率相对较低,可能诱发非预期纤维化。
要点
- 活检诊断癌的21例中12例(57.1%)切除后组织学为腺瘤。
- 活检诊断腺瘤的74例中15例(20.3%)切除后组织学为癌。
- 活检预测癌的敏感度37.5%,准确率71.6%。
核心结论
- 十二指肠活检取样的准确率相对较低,可能诱发非预期纤维化,亟需能提高NADET术前诊断率的新内镜方式。
研究设计与样本
- 回顾性复习95例浅表NADET(来自95例接受内镜切除的患者)的临床病理资料,将活检标本术前诊断与切除标本组织学诊断进行比较。
主要发现
- 活检诊断癌的21例病灶中12例(57.1%)切除后组织学诊断为腺瘤。
- 活检诊断腺瘤的74例病灶中15例(20.3%)切除后组织学诊断为癌。
- 活检预测最终癌诊断的敏感度为37.5%(95%CI,18.8-59.4),特异度为83.1%(95%CI,72.3-91.0),准确率为71.6%(95%CI,61.4-80.4),阳性预测值为42.9%(95%CI,21.8-66.0),阴性预测值为79.7%(95%CI,68.8-88.2)。
- 61例被认为适合EMR的病例中,15例(24.6%)因非抬举征从EMR转为内镜黏膜下剥离术。
临床怎么用
- 作者认为十二指肠活检取样准确率相对较低,可能诱发非预期纤维化,亟需能提高NADET术前诊断率的新内镜方式。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Endoscopic biopsy sampling for the diagnosis of duodenal adenocarcinoma is not perfect. We investigated the accuracy of biopsy specimen diagnoses of superficial nonampullary duodenal epithelial tumors (NADETs). METHODS: Clinicopathologic data were retrospectively reviewed for 95 superficial NADETs from 95 patients who underwent endoscopic resection. Preoperative diagnoses based on biopsy specimens were compared with histologic diagnoses of resected specimens. RESULTS: Among the 21 lesions with biopsy specimen diagnoses of carcinoma, 12 (57.1%) were histologically diagnosed as adenomas after resection. Among the 74 lesions with biopsy specimen diagnoses of adenoma, 15 (20.3%) were histologically diagnosed as carcinomas after resection. The duodenal biopsy specimen predicted final histologic diagnoses of carcinoma with a sensitivity of 37.5% (95% CI, 18.8-59.4), specificity of 83.1% (95% CI, 72.3-91.0), accuracy of 71.6% (95% CI, 61.4-80.4), positive predictive value of 42.9% (95% CI, 21.8-66.0), and negative predictive value of 79.7% (95% CI, 68.8-88.2). Among 61 cases considered suitable for EMR, treatment modality was converted from EMR to endoscopic submucosal dissection because of the nonlifting sign in 15 cases (24.6%). CONCLUSIONS: The accuracy of duodenal biopsy sampling was relatively low. Duodenal biopsy sampling may induce unexpected fibrosis. New endoscopic modalities that can improve preoperative diagnosis yield of NADETs are eagerly awaited.
引用
- Kinoshita S, Nishizawa T, Ochiai Y, et al. Accuracy of biopsy for the preoperative diagnosis of superficial nonampullary duodenal adenocarcinoma. Gastrointest Endosc. 2016. PMID: 28003118. doi:10.1016/j.gie.2016.12.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。