文献速递胰腺与胆道疾病消化内镜

两种新型抗移位设计全覆膜金属支架治疗胆道狭窄的比较效果:多中心倾向匹配研究

Comparative Effectiveness of Two Novel Anti-Migration Strategies in Fully Covered Self-Expandable Metal Stents for Biliary Strictures: A Multicenter Propensity-Matched Study.
PubMed 文献 · Gastrointest Endosc · 2026-10-30

多中心回顾性队列研究纳入228例接受全覆膜自膨式金属支架(FCSEMS)治疗胆道狭窄的患者,比较锚定凸起加远端扩大喇叭口设计(FCSEMS-AB)与锚定鳍设计(FCSEMS-AF)的移位与闭塞率,倾向匹配后分析64对。FCSEMS-AB移位风险显著更高,但闭塞风险更低。

要点

  • FCSEMS-AB较FCSEMS-AF的支架移位风险显著升高(aOR 5.25,95%CI 1.58-17.49,p=0.007)。
  • FCSEMS-AB校正后支架闭塞风险较低(aOR 0.27,95%CI 0.10-0.78,p=0.015),但时间事件分析无统计学显著性。
  • 两组死亡率无差异,支架选择需权衡抗移位与支架通畅性。

核心结论

  • FCSEMS-AB较FCSEMS-AF支架移位风险显著更高,而支架闭塞率更低,提示抗移位与支架通畅性之间存在权衡,可指导个体化支架选择。

研究设计与样本

  • 多中心回顾性队列研究,三家三级中心,共228例接受FCSEMS置入的患者,其中FCSEMS-AF组143例、FCSEMS-AB组85例,倾向评分匹配后分析64对。
  • 采用倾向评分匹配平衡基线特征,使用logistic回归和Cox比例风险模型评估结局。

主要发现

  • FCSEMS-AB较FCSEMS-AF支架移位几率显著更高:未校正OR 5.00(95%CI 1.57-15.94,p=0.007),校正后aOR 5.25(95%CI 1.58-17.49,p=0.007)。
  • 时间事件分析显示FCSEMS-AB移位风险升高(校正HR 6.26,95%CI 2.01-19.55,p=0.002)。
  • 校正logistic回归中FCSEMS-AB支架闭塞几率更低(aOR 0.27,95%CI 0.10-0.78,p=0.015),但时间事件分析中该关联无统计学显著性。
  • 两组死亡率无差异。

临床怎么用

  • 在选择FCSEMS治疗胆道狭窄时,需权衡FCSEMS-AB的较低闭塞率与较高移位风险,结合患者个体情况选择支架类型。

局限性

  • 为多中心回顾性队列研究,存在回顾性设计固有局限;倾向匹配后样本量有限(64对)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Fully covered self-expandable metal stents (FCSEMS) are used for benign and malignant biliary strictures, though stent migration and occlusion remain important limitations. A novel FCSEMS with an anchoring bump and enlarged distal flare (FCSEMS-AB) was recently introduced as an alternative anti-migration design to FCSEMS with anchoring fins (FCSEMS-AF). We compared migration and occlusion rates between these stent types. METHODS: We performed a multicenter retrospective cohort study of patients undergoing FCSEMS placement at three tertiary centers. Patients received either FCSEMS-AF (Viabil) or FCSEMS-AB (WallFlex Plus). Propensity score matching was performed to balance baseline characteristics. Logistic regression and Cox proportional hazards models were used to evaluate outcomes. RESULTS: Among 228 patients, 143 received FCSEMS-AF and 85 received FCSEMS-AB. After propensity matching, 64 matched pairs were analyzed. FCSEMS-AB was associated with significantly higher odds of stent migration compared with FCSEMS-AF in both unadjusted (OR 5.00, 95% CI 1.57-15.94, p=0.007) and adjusted analyses (aOR 5.25, 95% CI 1.58-17.49, p=0.007). Time-to-event analyses similarly demonstrated increased migration risk with FCSEMS-AB (adjusted HR 6.26, 95% CI 2.01-19.55, p=0.002). FCSEMS-AB was associated with lower odds of stent occlusion in adjusted logistic regression (aOR 0.27, 95% CI 0.10-0.78, p=0.015), though this association was not statistically significant in time-to-event analysis. Mortality did not differ between groups. CONCLUSIONS: FCSEMS-AB was associated with significantly higher migration risk compared with FCSEMS-AF, while demonstrating lower rates of stent occlusion. These findings highlight a trade-off between migration resistance and stent patency that may guide individualized stent selection.

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Ramai D, Fuller A, Bria A, et al. Comparative Effectiveness of Two Novel Anti-Migration Strategies in Fully Covered Self-Expandable Metal Stents for Biliary Strictures: A Multicenter Propensity-Matched Study. Gastrointest Endosc. 2026. PMID: 42962728. doi:10.1016/j.gie.2026.10.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。