锚爪夹钳牵拉肌层闭合结直肠ESD术后大缺损的前瞻性评估
单中心前瞻性研究评估锚爪夹钳(MANTIS Clip)闭合结直肠ESD术后30-50mm黏膜缺损的可行性、有效性与持久性。完全闭合率95.2%(20/21),中位闭合时间17分钟、中位用夹8枚;术后3-5天持续完全闭合率76.2%,延迟出血与穿孔均为0%。
要点
- 30-50mm结直肠ESD缺损用MANTIS Clip完全闭合率达95.2%(20/21)。
- 中位闭合时间17分钟,中位使用8枚夹。
- 标本≤59mm者全部闭合成功,≥60mm者75%成功。
核心结论
- MANTIS Clip对30-50mm结直肠ESD术后黏膜缺损实现高完全闭合率,短期持久性可接受。
研究设计与样本
- 单中心前瞻性研究,评估结直肠ESD后30-50mm病变缺损使用MANTIS Clip闭合。
- 夹钳抓取黏膜与肌层以加深褶皱并减少张力,主要终点为完全闭合率。
主要发现
- 完全闭合率95.2%(20/21),中位闭合时间17分钟,中位用夹8枚。
- 标本≤59mm缺损全部闭合成功,≥60mm者闭合成功率75%。
- 术后3-5天持续完全闭合率76.2%(16/21),≥2周95.2%出现部分或完全脱夹。
- 延迟出血0%、延迟穿孔0%、ESD后凝血综合征14.3%。
关键数值与推荐
- 完全闭合率95.2%(20/21)。
- 中位闭合时间17分钟,中位用夹8枚。
- 标本≤59mm全部闭合成功,≥60mm闭合成功率75%。
- 3-5天持续完全闭合76.2%(16/21)。
临床怎么用
- 可用于30-50mm结直肠ESD缺损的闭合,抓取黏膜与肌层以降低张力。
- 标本≥60mm时闭合成功率下降,需预判操作难度。
局限性
- 单中心前瞻性研究,样本量21例。
- 随访至≥2周,未报告更长期结局。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Complete mucosal defect closure after colorectal endoscopic submucosal dissection (ESD) may reduce delayed adverse events. However, the durable closure of large defects remains technically challenging. We prospectively evaluated the feasibility, efficacy, and durability of a novel anchor-pronged clip (MANTIS Clip; Boston Scientific Co., Massachusetts, United States) for defect closure after colorectal ESD. METHODS: This single-center prospective study evaluated defect closure using the MANTIS Clip after colorectal ESD for lesions measuring 30-50 mm. The clip was used to approximate the defect by grasping the mucosal and muscular layers to achieve deeper plication and tension reduction. The primary endpoint was the complete closure rate. The secondary endpoints included closure times, number of clips used, sustained closure, and adverse events. RESULTS: Complete closure was achieved in 95.2% (20/21) of cases during a median closure time of 17 min using a median of eight clips. Closure was successful in all defects with a specimen size ≤59 mm in size and in 75% of those ≥60 mm in size. Sustained complete closure was observed in 76.2% (16/21) of cases at 3-5 days and partial or complete dislodgement at ≥2 weeks after ESD in 95.2%. Delayed bleeding, delayed perforation, and post-ESD coagulation syndrome occurred in 0%, 0%, and 14.3% of cases, respectively. CONCLUSIONS: The MANTIS Clip achieved a high complete closure rate with acceptable short-term durability for mucosal defects after colorectal ESD of lesions measuring 30-50 mm.
引用
- Ashizawa H, Imai K, Hotta K, et al. Prospective evaluation of tension-reducing closure with intentional muscle-layer grasping for large colorectal post-ESD defects using an anchor-pronged clip (MANTIS study). Gastrointest Endosc. 2026. PMID: 42716255. doi:10.1016/j.gie.2026.08.053
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。