荷兰国家内镜与病理数据库自动链接用于息肉检出率持续监测的可行性及初步结果
本研究评估了荷兰国家内镜与病理数据库自动链接的可行性,共纳入182,539例结肠镜检查(36个单位),发现各单位充分链接比例依指征类别为47%至94%;常规诊断性结肠镜检查的中位腺瘤检出率为37.5%,多数单位达到既定息肉检出性能目标,但单位间差异明显。
要点
- 自动链接荷兰国家内镜与病理数据库可行,支持息肉检出指标的大规模监测。
- 常规诊断性结肠镜检查中位腺瘤检出率为37.5%,单位间范围26.7%至47.9%。
- 多数单位达到腺瘤检出率、每结肠镜腺瘤数和广基锯齿状病变检出率目标。
核心结论
- 荷兰国家内镜与病理数据库的自动链接可实现可扩展、资源高效的息肉检出指标监测,多数单位达到既定性能目标,但单位间差异较大。
研究设计与样本
- 研究链接荷兰胃肠内镜审计与全国病理解剖自动归档(PALGA)数据,采用自动化逐步链接方案,纳入链接充分的单位,共分析182,539例结肠镜检查(36个单位)。
主要发现
- 充分PALGA链接的单位比例依指征类别为47%至94%。
- 粪便免疫化学试验阳性后结肠镜检查的中位腺瘤检出率为59.3%(范围49.4%-68.3%)。
- 常规诊断性结肠镜检查(监测、家族风险或症状相关指征合并)的中位腺瘤检出率为37.5%(范围26.7%-47.9%)。
- 常规诊断性结肠镜检查中,分别有71%、90%和86%的单位达到腺瘤检出率、每结肠镜腺瘤数和广基锯齿状病变检出率的性能目标。
临床怎么用
- 可利用国家内镜与病理数据库自动链接持续监测息肉检出指标,识别单位间差异并推动质量改进。
局限性
- 充分链接比例依指征类别存在差异(47%至94%),且需所有单位提供结构化数据以进一步发挥链接可行性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Polyp detection metrics are key quality indicators for colonoscopy. The widespread monitoring of these metrics is hindered by the need to link endoscopy and histopathology data. This study assessed the feasibility of automated linking of data from the Dutch national endoscopy and pathology databases to enable continuous monitoring of polyp detection metrics. METHODS: Data from the Dutch Gastrointestinal Endoscopy Audit and Automated National Pathological Anatomy Archive (PALGA) were linked using an automated stepwise linking protocol. Units with adequate linkage were included to evaluate polyp detection metrics across categorized diagnostic colonoscopy indications, interunit variability in these metrics, and the extent to which units achieve established polyp detection performance targets. RESULTS: In total, 182,539 colonoscopies (36 units) were included. The proportion of units with adequate PALGA linkage ranged from 47% to 94%, depending on the indication category. The median adenoma detection rate (ADR) was 59.3% (range: 49.4%-68.3%) for colonoscopies after a positive fecal immunochemical test and 37.5% (range: 26.7%-47.9%) for routine diagnostic colonoscopies (surveillance, familial risk, or symptom-related indications combined). The ADR, adenomas per colonoscopy, and sessile serrated lesion detection rate performance targets for routine diagnostic colonoscopies were achieved by 71%, 90%, and 86% of units, respectively. CONCLUSIONS: Automated linkage across the Dutch national endoscopy and pathology databases enables scalable, resource-efficient monitoring of polyp detection metrics. Most units achieve established polyp detection performance targets, although considerable interunit variability was observed. To further leverage the feasibility of the linking process, the availability of structured data is required across all units.
引用
- van Bokhorst QNE, Nass KJ, Reijnders JGP, et al. Automated linking of data from the Dutch national endoscopy and pathology databases for continuous monitoring of polyp detection rates: feasibility and first results. Gastrointest Endosc. 2026. PMID: 42349756. doi:10.1016/j.gie.2026.06.035
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。