美国三家内镜中心常规内镜操作的碳足迹综合评估
该前瞻性一周审计在3家美国内镜中心评估133例常规内镜操作的碳足迹,涵盖术前术后护理、镇静、患者交通、再处理及暖通空调与能源需求。结果显示每例常规内镜平均排放53.2 kgCO2e,结肠镜与上消化道内镜相近,同一天完成两者可减少42%的联合碳足迹。暖通空调与电力合计占42%,患者交通占29%,耗材占22%,再处理占4%。
要点
- 常规内镜每例平均碳足迹为53.2 kgCO2e,结肠镜与上消化道内镜相近。
- 暖通空调与电力是最大排放源,合计占42%,患者交通占29%。
- 同一天完成上消化道内镜和结肠镜可减少42%的联合碳足迹。
核心结论
- 常规内镜操作碳排放相近,但不同内镜中心间差异显著。
- 暖通空调与能源使用是总排放的最大贡献者,提示站点特异性减排可能最具碳节约潜力。
研究设计与样本
- 前瞻性一周审计,纳入美国3家内镜中心的133例常规内镜操作。
- 采用生命周期评估量化碳足迹,以kgCO2e表示,涵盖术前术后护理、镇静、患者交通、再处理及暖通空调与能源需求。
主要发现
- 常规内镜平均碳足迹为53.2 kgCO2e,结肠镜为55.2 kgCO2e,食管胃十二指肠镜为51.5 kgCO2e。
- 同一天为同一患者进行食管胃十二指肠镜和结肠镜可使联合碳足迹减少42%。
- 暖通空调与电力合计占42%排放,患者交通占29%,耗材占22%,再处理占4%。
- 各内镜中心排放从44.9至68.7 kgCO2e不等,差异达1.5倍。
临床怎么用
- 可考虑将同一患者的上消化道内镜与结肠镜安排在同一天,以降低联合碳足迹。
- 内镜中心可优先评估暖通空调与能源使用的减排潜力,因其为最大排放源。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND & AIMS: Health care is a major contributor to greenhouse gas emissions; however, data on the carbon footprint of performing endoscopic procedures are limited. We aimed to quantify the emissions generated by performing a routine endoscopic procedure. METHODS: We conducted a prospective 1-week audit of endoscopic procedures at 3 United States endoscopy units that included pre- and post-procedural care; sedation; patient travel; reprocessing; heating, ventilation, and air conditioning; and energy needs. A life cycle assessment was applied to quantify the carbon footprint of performing a routine endoscopic procedure, expressed as kgCO2e. We further examined the contribution of emission sources and compared colonoscopy and upper endoscopy emissions. RESULTS: A total of 133 routine endoscopies were audited. Fifty-nine percent were performed with monitored anesthesia care, and 82% involved ancillary instruments (snare, forceps, or hemoclip). The mean carbon footprint of a routine endoscopy was 53.2 kgCO2e, with similar emissions for colonoscopy and esophagogastroduodenoscopy (55.2 and 51.5 kgCO2e, respectively). Performing esophagogastroduodenoscopy and colonoscopy for the same patient on the same day reduces the combined carbon footprint by 42%. Heating, ventilation, and air conditioning and electricity together accounted for 42% of emissions, patient travel for 29%, supplies for 22%, and reprocessing for 4%. Emissions varied substantially across endoscopy units, ranging from 44.9 to 68.7 kgCO2e, a 1.5-fold difference. CONCLUSIONS: This comprehensive carbon footprint analysis demonstrated comparable emissions across routine endoscopic procedures, but notable variation between endoscopy units. Heating, ventilation, and air conditioning and energy use were the largest contributors to total emissions, suggesting that site-specific reductions may yield the greatest potential for carbon savings in routine endoscopy.
引用
- Gayam S, Gordon IO, Smolen KA, et al. Carbon Footprint of Routine Endoscopic Procedures: A Comprehensive Assessment in Three United States Endoscopy Units. Clin Gastroenterol Hepatol. 2026. PMID: 42314788. doi:10.1016/j.cgh.2026.06.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。