文献速递消化内镜消化道肿瘤与早癌

计算机辅助检测设备可用性对结肠镜腺瘤检出率的影响:一项整群随机研究

Impact of Availability of Computer-Aided Detection Devices on Adenoma Detection During Colonoscopy: A Cluster Randomized Study.
PubMed 文献 · Gastroenterology · 2026-06-05

结果显示,CADe机构腺瘤检出率绝对增加4.2个百分点(95%CI 3.48-4.74),从50.7%升至54.9%;对照机构下降0.7个百分点(95%CI -1.16至-0.28),从51.8%降至51.1%。多变量回归显示CADe可用性与腺瘤检出几率显著增加相关(OR 1.22,95%CI 1.15-1.28),但与其它病变检出或退镜时间变化无关。

要点

  • CADe设备可用使腺瘤检出率绝对提高4.2个百分点。
  • CADe可用性与腺瘤检出几率增加独立相关(OR 1.22)。
  • CADe对癌症结局和内镜医师技能退化的影响尚不明确。

核心结论

  • 与常规护理相比,CADe设备可用性与腺瘤检出显著增加相关。
  • CADe对癌症结局和内镜医师潜在技能退化的影响仍未确定。

研究设计与样本

  • CADe机构数据来自42家机构的269名内镜医师,部署前71,594例和部署后35,399例结肠镜检查。
  • 对照机构数据来自97家机构的547名内镜医师,部署前151,792例和部署后75,415例结肠镜检查。
  • 采用混合效应逻辑回归评估CADe可用性对结肠镜检查结果的独立效应。

主要发现

  • CADe机构腺瘤检出率从部署前50.7%升至部署后54.9%,绝对增加4.2个百分点(95%CI 3.48至4.74个百分点)。
  • 对照机构腺瘤检出率从部署前51.8%降至部署后51.1%,下降0.7个百分点(95%CI -1.16至-0.28个百分点)。
  • 多变量回归显示CADe可用性与腺瘤检出几率显著增加相关(OR 1.22;95%CI 1.15至1.28)。
  • CADe可用性与其它病变检出或退镜时间变化无关。
  • 基线内镜医师腺瘤检出率五分位数与CADe可用性对腺瘤检出率的影响无关。

临床怎么用

  • 在真实世界实践中,配备CADe设备可能有助于提高结肠镜腺瘤检出率。
  • CADe对癌症结局和内镜医师技能退化的影响尚不明确,需进一步评估。

局限性

  • 研究未确定CADe对癌症结局的影响。
  • 研究未确定CADe对潜在内镜医师技能退化的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND & AIMS: Endoscopists' colonoscopy adenoma detection rates (ADRs) are inversely associated with their patients' risk of postcolonoscopy colorectal cancer death. Although randomized controlled trials have found that computer-aided detection (CADe) devices significantly improve ADRs, real-world studies have generally failed to demonstrate a benefit. METHODS: In this pragmatic quality improvement study, randomly selected Veterans Health Administration facilities were equipped with CADe devices between October 2022 and February 2023. Control facilities were assigned a random deployment date. Adenoma detection was determined for colonoscopies, and mixed effects logistic regression was used to assess the independent effect of CADe availability on colonoscopy outcomes. RESULTS: Colonoscopy data were available from 269 endoscopists at 42 facilities with CADe performing 71,594 pre- and 35,399 postdeployment colonoscopies; and from 547 endoscopists at 97 control facilities performing 151,792 pre- and 75,415 postdeployment colonoscopies. Comparing post- with predeployment colonoscopies, the absolute increase in ADR was 4.2 percentage points (95% CI, 3.48 to 4.74 percentage points), from 50.7% to 54.9%, at CADe sites and ADR decreased by 0.7 percentage points (95% CI, -1.16 to -0.28 percentage points), from 51.8% to 51.1%, at control sites. Using multivariable regression, CADe availability was associated with a significantly increased odds of adenoma detection (odds ratio, 1.22; 95% CI, 1.15 to 1.28), but was not associated with detection of other lesions or changes in withdrawal time. Baseline endoscopist ADR quintiles were not associated with the impact of CADe availability on ADR. CONCLUSIONS: Availability of CADe devices was associated with a significant increase in adenoma detection compared with usual care. The impact on cancer outcomes and potential endoscopist deskilling remains undetermined. CLINICALTRIALS: gov Number: NCT05888623.

来源:Gastroenterology,查看原文。版权归原作者所有。

引用

  1. Dominitz JA, Gawron AJ, McKee GB, et al. Impact of Availability of Computer-Aided Detection Devices on Adenoma Detection During Colonoscopy: A Cluster Randomized Study. Gastroenterology. 2026. PMID: 42250891. doi:10.1053/j.gastro.2026.05.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。