文献速递胃肠动力与功能性疾病消化内镜

经口内镜下肌切开术全层与环形肌切开疗效与安全性随机非劣效试验

Efficacy and safety of full-thickness versus circular muscle myotomy in peroral endoscopic myotomy: a randomized controlled noninferiority trial.
PubMed 文献 · Gastrointest Endosc · 2026-06-25

单中心随机非劣效试验纳入69例I或II型贲门失弛缓症患者,比较全层肌切开(FTM)与环形肌切开(CMM)。术后6个月临床成功率FTM组91.2%、CMM组85.7%,组间差5.5%(90%CI -7.1%~18.1%),下限高于-10%非劣效界值,FTM非劣效于CMM。

要点

  • FTM术后6个月临床成功率非劣效于CMM(差5.5%,90%CI -7.1%~18.1%)

核心结论

  • FTM在短期疗效上非劣效于CMM,但注气相关事件显著增加且术后反流有增多趋势,安全性劣势限制其作为CMM常规替代方案推荐。

研究设计与样本

  • 单中心随机非劣效试验纳入69例I或II型贲门失弛缓症患者,FTM组34例、CMM组35例,预设非劣效界值为-10%。

主要发现

  • 意向性分析中术后6个月临床成功率FTM组91.2%、CMM组85.7%,组间差5.5%(90%CI -7.1%~18.1%),下限高于-10%界值。

关键数值与推荐

  • 主要结局为术后6个月临床成功,定义为Eckardt评分≤3。
  • 非劣效界值预设为-10%,组间差90%CI下限-7.1%高于界值即判定非劣效。

临床怎么用

  • FTM短期疗效与CMM相当,但注气相关事件和术后反流风险更高,不宜作为CMM的常规替代。
  • 选择FTM时应权衡其更显著降低基础下食管括约肌压力的获益与安全性劣势。

局限性

  • 单中心研究,样本量较小(69例),结果外推需谨慎。
  • 随访仅报告术后6个月短期结局,缺乏长期疗效与反流数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIM: Peroral endoscopic myotomy is a standard treatment for achalasia (AC). The conventional approach involves circular muscle myotomy (CMM), but full-thickness myotomy (FTM) may offer more profound lower esophageal sphincter (LES) reduction. This randomized controlled noninferiority trial primarily determined whether FTM achieved clinical success noninferior to CMM. METHODS: This single-center, randomized noninferiority trial enrolled 69 patients with type I or II AC assigned to the FTM group (n = 34) or the CMM group (n = 35). The primary outcome was clinical success (Eckardt score ≤3) at 6 months after the procedure. A noninferiority margin of -10% was prespecified. Secondary outcomes included procedure-related metrics, safety outcomes or adverse events, physiological and anatomical outcomes, and GERD-related outcomes. RESULTS: In the intention-to-treat analysis, clinical success rates were 91.2% in the FTM group and 85.7% in the CMM group, with a group difference of 5.5% (90% CI, -7.1% to 18.1%). Because the lower CI bound (-7.1%) was above -10%, FTM was noninferior to CMM. FTM was associated with significantly higher insufflation-related events (32.35% vs 11.43%; P = .035). There was a trend toward more frequent moderate-to-severe intraoperative bleeding in the FTM group (41.18% vs 22.86%; P = .103). FTM resulted in significantly lower basal LES pressure than CMM (6.85 vs 11.70 mm Hg; P = .024). Postoperative esophagitis showed a numerical trend toward an increase in the FTM group (36.36% vs 18.18%; P = .097). CONCLUSIONS: FTM was noninferior to CMM in short-term efficacy. However, FTM was associated with a significantly higher incidence of insufflation-related events and demonstrated a potential increase in postprocedural reflux. Despite the comparable efficacy, the disadvantages in the safety of FTM limit its recommendation as a routine alternative to CMM in the management of AC.

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Hu YW, Xi WF, Li YF, et al. Efficacy and safety of full-thickness versus circular muscle myotomy in peroral endoscopic myotomy: a randomized controlled noninferiority trial. Gastrointest Endosc. 2026. PMID: 42349760. doi:10.1016/j.gie.2026.06.034