文献速递食管胃疾病与幽门螺杆菌胃肠动力与功能性疾病消化内镜

米兰评分在96小时无线pH监测中的验证

Validation of the Milan Score Using Prolonged Wireless PH Monitoring.
PubMed 文献 · Aliment Pharmacol Ther · 2026-04-14

本研究在90例有GERD症状的成人中验证米兰评分对病理性反流的预测价值,以96小时无线pH监测按Lyon共识2.0判定结论性GERD。结果显示米兰评分阳性者GERD组占65%、非GERD组占19%,ROC曲线AUC为0.812,最佳阈值151.84时敏感度60.4%、特异度92.9%。

要点

  • 米兰评分可基于高分辨率测压自动计算,用于量化抗反流屏障破坏。
  • 在96小时无线pH监测中,米兰评分预测结论性GERD的AUC为0.812。
  • 最佳阈值151.84时敏感度60.4%、特异度92.9%。

核心结论

  • 异常米兰评分可可靠预测96小时无线pH监测下符合Lyon共识2.0的病理性反流,性能与24小时pH-阻抗监测相似。

研究设计与样本

  • 回顾性收集2023至2025年意大利IRCCS Policlinico San Donato和美国Washington University in St. Louis连续接受高分辨率测压和96小时无线pH监测的GERD症状成人。
  • 共纳入90例患者,年龄54岁,女性59%,BMI 25 kg/m2,其中48例为结论性GERD。
  • 米兰评分由高分辨率测压指标自动计算,pH监测按Lyon共识2.0以至少2天酸暴露时间>6%定义结论性GERD,采用ROC分析评估诊断性能。

主要发现

  • GERD组食管裂孔疝患病率65%高于非GERD组的35%(p=0.006)。
  • GERD组直腿抬高动作诱导的食管内压升高中位数14 mmHg高于非GERD组的3 mmHg(p<0.001)。
  • 米兰评分阳性在GERD组占65%、非GERD组占19%(p<0.001),且评分值随pH阳性天数增加而升高。
  • ROC分析显示米兰评分预测结论性GERD的AUC为0.812(95%CI:0.718-0.895),最佳阈值151.84,敏感度60.4%,特异度92.9%。

关键数值与推荐

  • 结论性GERD按Lyon共识2.0定义为96小时无线pH监测中至少2天酸暴露时间>6%。
  • 米兰评分最佳阈值151.84,对应敏感度60.4%、特异度92.9%、AUC 0.812(95%CI:0.718-0.895)。

临床怎么用

  • 对接受高分辨率测压的GERD症状患者,可自动计算米兰评分辅助判断病理性反流概率。
  • 米兰评分阳性提示抗反流屏障破坏,可支持GERD诊断并指导后续pH监测决策。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIM: In 2024, a novel high-resolution manometry (HRM) metric termed the Milan Score was introduced to quantify anti-reflux barrier disruption and estimate the probability of pathologic gastroesophageal reflux disease (GERD). This composite score incorporates oesophagogastric junction (EGJ) barrier metrics, oesophageal motor function and response to the straight leg raise (SLR) manoeuvre. Prior validations relied on acid exposure time (AET) > 6% on 24-h pH-impedance studies, making the outcome susceptible to day-to-day variability. The aim of this study is to validate the effectiveness of the Milan Score in predicting GERD using 96-h wireless pH-monitoring. METHODS: Data from consecutive adults with GERD symptoms undergoing HRM and 96-h wireless pH-monitoring (2023-2025) at IRCCS Policlinico San Donato (Italy) and Washington University in St. Louis (USA) were retrospectively collected. Milan Score was calculated automatically from HRM metrics. pH studies followed Lyon Consensus 2.0 criteria, defining conclusive GERD as AET > 6% on ≥ 2 days. Diagnostic performance was evaluated by receiver operator characteristics (ROC) analysis. RESULTS: Among the 90 included patients (age 54 years, 59% females, BMI 25 kg/m2), 48 had conclusive GERD. Hiatal hernia prevalence (65% vs. 35%, p = 0.006) and median SLR-induced intra-oesophageal pressure increase (14 vs. 3 mmHg, p < 0.001) were higher in GERD patients. Positive Milan Score was found in 65% of GERD vs. 19% of non-GERD group (p < 0.001). Milan Score values increased with higher number of positive pH days. ROC yielded AUC of 0.812 for conclusive GERD (95% CI: 0.718-0.895, optimal threshold 151.84, sensitivity 60.4%, specificity 92.9%). CONCLUSIONS: Abnormal Milan Score reliably predicts pathologic reflux per Lyon Consensus 2.0 on 96-h wireless pH-monitoring, with performance similar to 24-h pH-impedance. This validation strengthens evidence for the Milan Score in GERD diagnosis.

来源:Aliment Pharmacol Ther,查看原文。版权归原作者所有。

引用

  1. Siboni S, Mema J, McCarthy T, et al. Validation of the Milan Score Using Prolonged Wireless PH Monitoring. Aliment Pharmacol Ther. 2026. PMID: 41979402. doi:10.1111/apt.70668

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。