INTELCAPE:深度学习驱动胶囊内镜自动高精度诊断克罗恩病
本研究开发了人工智能系统INTELCAPE,基于757例和115例患者胶囊内镜视频,实现小肠分割、病灶检测和克罗恩病诊断。系统诊断准确率达90%,与专家相当但快10倍,并将医生诊断准确率从76.7%提升至94.8%,读片时间从67.9分钟缩短至22.5分钟。
要点
- INTELCAPE自动分析胶囊内镜视频,诊断克罗恩病准确率90%,与专家相当。
- 系统将医生诊断准确率从76.7%提升至94.8%,读片时间从67.9分钟降至22.5分钟。
- 病灶检测分类准确率99.33%,优于住院医师,与专家相当。
核心结论
- INTELCAPE通过自动化胶囊内镜视频分析,提高了克罗恩病诊断的准确性和效率,尤其惠及经验较少的临床医生。
研究设计与样本
- 回顾性多中心研究,使用中国2家医院757例(队列1)和115例(队列2)患者的胶囊内镜视频。
- 多任务深度学习框架,整合ResNet、Transformer和EfficientNet架构进行层次化处理。
- 以3项指标与临床医生进行性能比较。
主要发现
- 小肠分割的交并比:队列1为94.82%(95%CI 93.28%-96.36%),队列2为96.87%(95%CI 94.63%-99.12%)。
- 病灶检测的AUC:队列1为0.993,队列2为0.980;分类准确率99.33%,与专家(97.83%)相当,优于住院医师(91.05%;P<.001)。
- 克罗恩病诊断的AUC:队列1为0.982,队列2为0.984;诊断准确率90%,与专家(93.33%)相当,但速度快10倍(P<.001)。
- INTELCAPE将医生诊断准确率从76.7%提升至94.8%(P<.001),读片时间从67.9分钟缩短至22.5分钟(P<.001)。
临床怎么用
- 可辅助经验较少的医生提高克罗恩病胶囊内镜诊断准确性并缩短读片时间。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND & AIMS: Capsule endoscopy (CE) is a noninvasive technique for diagnosing Crohn's disease (CD); however, manual interpretation of CE videos is time-consuming and error-prone. We developed an artificial intelligence system, INTELCAPE, to automate CE video analysis for accurate and efficient CD diagnosis. METHODS: This retrospective, multi-center study used data from 2 Chinese hospitals. A multi-task deep learning framework segmented small-intestine regions, detected lesions, and diagnosed CD using CE videos from 757 (Cohort 1) and 115 (Cohort 2) patients. INTELCAPE integrated the ResNet, Transformer, and EfficientNet architectures for hierarchical processing. Performance was benchmarked against clinicians using 3 metrics. This study received Ethics Committee approval (2024ZSLYEC-040). RESULTS: INTELCAPE achieved state-of-the-art performance across all tasks. For small-intestine segmentation, the model showed intersection over union scores of 94.82% (Cohort 1, 95% confidence interval, 93.28%-96.36%) and 96.87% (Cohort 2, 95% confidence interval, 94.63%-99.12%). For lesion detection, it achieved area under the curve values of 0.993 (Cohort 1) and 0.980 (Cohort 2), with 99.33% classification accuracy, which was comparable to that of specialists (97.83%) but superior to that of residents (91.05%; P < .001). For CD diagnosis, INTELCAPE demonstrated robust generalizability, achieving area under the curve values of 0.982 (Cohort 1) and 0.984 (Cohort 2) with 90% diagnostic accuracy, comparable to that of specialists (93.33%) but 10-fold faster (P < .001). INTELCAPE improved doctors' diagnostic accuracy (76.7%-94.8%; P < .001), while reducing their interpretation time (67.9-22.5 minutes; P < .001). CONCLUSIONS: INTELCAPE improved CD diagnosis by automating CE video analysis, thereby enhancing accuracy and efficiency, particularly for less-experienced clinicians.
引用
- Fan D, Mao Y, Liang F, et al. INTELCAPE: A Deep Learning-Powered System for Automated, High-Accuracy Crohn's Disease Diagnosis via Capsule Endoscopy. Clin Gastroenterol Hepatol. 2026. PMID: 41861933. doi:10.1016/j.cgh.2026.02.026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。