计算机辅助息肉检测多中心国际随机对照研究:聚焦社区诊所的老年评估驱动干预临床试验
该多中心国际随机对照试验评估DEEP2计算机辅助息肉检测(CADe)系统对结肠镜检查质量指标的影响,纳入1407例常规结肠镜检查参与者,多数来自社区诊所(85.9%)。事后分析提示社区诊所中DEEP2对APC和ADR有显著获益,支持在社区实践中纳入CADe设备。
要点
- DEEP2 CADe系统可显著提高每结肠镜腺瘤检出数(APC)。
- PPA非劣效性未证实,需关注假阳性风险。
- 社区诊所中CADe对APC和ADR的获益更显著。
核心结论
- DEEP2 CADe系统可提高结肠镜检查的腺瘤检出效率,尤其在社区诊所中获益显著。
研究设计与样本
- 多中心国际随机对照试验,纳入1407例常规结肠镜检查参与者,随机分为标准高清晰白光内镜对照组和DEEP2 CADe辅助组。
主要发现
- 事后分析显示社区诊所中DEEP2对APC和ADR有显著获益。
临床怎么用
- 在社区诊所结肠镜实践中可考虑纳入CADe设备以提高腺瘤检出效率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Computer-aided polyp detection (CADe) systems can enhance polyp detection, although their performance has largely been evaluated at academic rather than community practices. This randomized controlled trial evaluated the impact of the DEtection of Elusive Polyps-2 (DEEP2) CADe system on colonoscopy quality metrics. METHODS: Participants undergoing routine colonoscopies were randomized to a control arm, standard-of-care high-definition white-light endoscopy (HD-WLE), or an intervention arm, HD-WLE with real-time DEEP2 system assistance. Coprimary end points: adenomas per colonoscopy (APC; superiority evaluation at a 0.025 level of significance), and percent positive agreement (PPA, defined [per regulatory request] as the proportion of histologically confirmed clinically significant excised lesions relative to total lesions; noninferiority evaluation with a lower 95% CI threshold of -10%). Secondary end points included adenoma detection rate (ADR), polyp detection rate, polyps per colonoscopy, false positive rate, and false alarm rate. RESULTS: This study enrolled 1407 participants, most in community clinics (n = 1208, 85.9%). Use of the DEEP2 system resulted in significantly higher APC (0.74 vs 0.60; difference, 0.14; P = .0002). The PPA difference was -0.06 (95% CI, -0.15 to 0.03; P = .09). There was a numerical, but not statistically significant, ADR improvement (42.9% vs 38.9%; P = .031). A post hoc analysis revealed significant benefit in APC and ADR with the DEEP2 system only within community clinics. CONCLUSIONS: These results support the incorporation of CADe devices into colonoscopy practice for improving efficacy and quality over standard-of-care, particularly in community practices.
引用
- Leggett CL, Plowman RS, Surace L, et al. Computer-aided polyp detection multicenter international randomized controlled study with a focus on community clinics: Geriatric Assessment-Driven Intervention clinical trial. Gastrointest Endosc. 2026. PMID: 41548723. doi:10.1016/j.gie.2025.12.290
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。