文献速递胃肠动力与功能性疾病消化内镜

婴儿胃食管反流12小时与24小时食管pH阻抗监测可靠性比较

Assessing the Reliability of 12- vs 24-Hour Esophageal pH-Impedance Monitoring for Gastroesophageal Reflux in Infants.
PubMed 文献 · Am J Gastroenterol · 2025-10-13

12小时监测诊断GERD的敏感性87.7%、特异性75.6%、阳性预测值89.7%、阴性预测值71.7%;仅持续>5分钟的GER事件数在12小时与24小时分析间有显著差异(1.97±0.27 vs 1.83±0.44,P<0.001),其余指标无显著差异。

要点

  • 12小时MII-pH诊断婴儿GERD的敏感性87.7%、特异性75.6%,与24小时监测总体一致性良好。
  • 仅持续>5分钟的GER事件数在12小时与24小时分析间存在显著差异,但临床意义不明确。
  • 总GER和近端GER事件数/小时、反流指数、团注暴露指数等指标在12小时与24小时分析间无显著差异。

核心结论

  • 12小时MII-pH监测与24小时记录相比具有良好的诊断性能,可作为婴儿GERD评估的替代方案。

研究设计与样本

  • GERD诊断标准为以下任一:24小时内GER事件数≥100次,近端GER事件>44次(酸性)或>57次(非酸性),反流指数(pH<4时间百分比)>7%,团注暴露指数>2.4%,团注清除时间>18秒,症状指数≥50%,症状相关概率≥95%。
  • 采用单变量分析比较MII-pH数据。

主要发现

  • 研究对象中位年龄61天(IQR 27-116),其中49例为早产儿。
  • 12小时与24小时分析在总GER和近端GER事件数/小时、反流指数、团注暴露指数、团注清除时间、阳性症状指数/症状相关概率方面无显著差异。
  • 持续>5分钟的GER事件数/小时在12小时与24小时分析分别为1.97±0.27和1.83±0.44,差异有统计学意义(P<0.001)。
  • 12小时MII-pH诊断GERD的敏感性87.7%、特异性75.6%、阳性预测值89.7%、阴性预测值71.7%(以24小时MII-pH为参照)。

关键数值与推荐

  • GERD诊断阈值:24小时内GER事件数≥100次。
  • 近端GER事件阈值:酸性>44次,非酸性>57次。
  • 反流指数>7%,团注暴露指数>2.4%,团注清除时间>18秒。
  • 症状指数≥50%,症状相关概率≥95%。

临床怎么用

  • 在需要缩短监测时间的婴儿中,可考虑采用12小时MII-pH替代24小时监测以评估GERD。
  • 解读12小时结果时需注意持续>5分钟的GER事件数可能被低估,但其临床意义尚不明确。

局限性

  • 为回顾性研究设计。
  • 仅持续>5分钟的GER事件数在12小时与24小时分析间存在显著差异,但该观察的临床意义不明确。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The recommended duration of esophageal multichannel intraluminal impedance pH (MII-pH) monitoring to detect gastroesophageal reflux (GER) is currently 24 hours. This prolonged recording can be challenging in certain circumstances. We aimed to assess the diagnostic reliability of 12- vs 24-hour MII-pH in infants. METHODS: Retrospective multicenter study assessing MII-pH tracings from infants referred for suspect gastroesophageal reflux disease (GERD). Each MII-pH was analyzed twice as full-time recording and in the first 12 hours, and data were compared. GERD was diagnosed if one of the following occurred: number of GER episodes ≥100 in 24 hours, proximal GER episodes >44 (acid) or 57 (nonacid), reflux index (percent time with pH < 4) >7%, Bolus Exposure Index >2.4%, Bolus Clearance Time >18 seconds, Symptom index ≥50%, and Symptom Association Probability ≥95%. Univariate analysis was performed to compare MII-pH data. RESULTS: One hundred twenty-seven infants were studied. The median age at MII-pH was 61 days (interquartile range-IQR 27-116), and 49 were born preterm. There were no significant differences between the 12- and the 24-hour analysis regarding the number of total GER and proximal GER events/hr, reflux index, Bolus Exposure Index, Bolus Clearance Time, positive Symptom index/Symptom Association Probability. GER events lasting >5 min/hr were 1.97 ± 0.27 and 1.83 ± 0.44, respectively ( P < 0.001). The 12-hour MII-pH recording showed 87.7% sensitivity, 75.6% specificity, 89.7% positive predictive value, and 71.7% negative predictive value for GERD compared with 24-hour MII-pH. DISCUSSION: Twelve-hour MII-pH had a good diagnostic performance compared with 24-hour recording. Only GER events lasting >5 minutes were significantly different between the 2, but the clinical significance of this observation is unclear.

来源:Am J Gastroenterol,查看原文。版权归原作者所有。

引用

  1. Nobile S, Rotunno G, Vandenplas Y, et al. Assessing the Reliability of 12- vs 24-Hour Esophageal pH-Impedance Monitoring for Gastroesophageal Reflux in Infants. Am J Gastroenterol. 2025. PMID: 41081569. doi:10.14309/ajg.0000000000003796

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。