系统综述:肠道超声推动炎症性肠病诊疗低碳化
结果显示胃肠内镜每例约产生7.8-56.4 kg CO2当量,CT直接生命周期评估为每例7-10 kg CO2e,MRI多数研究为每次扫描17-22 kg CO2e,而肠道超声每次扫描仅0.5-1.5 kg CO2e。作者认为肠道超声是临床有效且低碳的替代选择,可促进炎症性肠病管理的可持续性。
要点
- 肠道超声每次扫描仅产生0.5-1.5 kg CO2e,能耗低且废物极少
- 胃肠内镜每例约产生7.8-56.4 kg CO2当量,主要来自交通、能源和一次性用品
- 肠道超声可即时床旁评估,减少患者出行及相关排放
核心结论
- 胃肠内镜、CT和MRI在炎症性肠病诊疗中不可或缺但环境成本可观,更广泛采用肠道超声可提供临床有效且低碳的替代方案。
主要发现
- 胃肠内镜每例约产生7.8-56.4 kg CO2当量,主要由交通、能源使用和一次性用品驱动。
- CT在直接生命周期评估中每例碳足迹为7-10 kg CO2e,更广泛的机构和建模估计可扩展至约20 kg CO2e,取决于吞吐量、方案和能源来源。
- MRI在多数研究中每次扫描为17-22 kg CO2e,当纳入完整生命周期影响时高场(3T)系统可达200-300 kg CO2e。
- 肠道超声每次扫描仅产生0.5-1.5 kg CO2e,能源需求极低且废物可忽略。
- 肠道超声支持床旁评估,减少患者出行及相关排放。
临床怎么用
- 在炎症性肠病诊疗中可考虑更广泛采用肠道超声作为低碳替代诊断方式,以减少碳足迹并支持床旁评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Inflammatory bowel disease (IBD) is a chronic, resource-intensive condition requiring repeated diagnostic assessments. Healthcare contributes ~5% of global greenhouse gas emissions, and key diagnostic tools in IBD-gastrointestinal (GI) endoscopy, computed tomography (CT) and magnetic resonance imaging (MRI)-are associated with substantial environmental impacts. The environmental burden of these diagnostic pathways, however, remains underappreciated. AIM: To systematically assess the carbon footprint and environmental impact of diagnostic imaging modalities commonly used in IBD, with particular focus on intestinal ultrasound (IUS) as a sustainable, low-carbon alternative. METHODS: A systematic review was conducted according to PRISMA 2020 guidelines. PubMed, Scopus and Embase were searched from inception to May 2025 for studies reporting the environmental impact of diagnostic modalities relevant to IBD care (GI endoscopy, CT, MRI and IUS). Studies providing quantitative or qualitative data on carbon footprint, energy consumption, waste generation or sustainability metrics were included. Data were synthesised narratively. RESULTS: Thirty-one studies were included. GI endoscopy generates approximately 7.8-56.4 kg CO2-equivalent per procedure, largely driven by transportation, energy use and disposables. CT carries a carbon footprint of 7-10 kg CO2e per procedure in direct life cycle assessments, while broader institutional and modelling estimates extend this to ~20 kg CO2e depending on throughput, protocol and energy sources. MRI is substantially more energy-intensive, ranging from 17-22 kg CO2e per scan in most studies, and up to 200-300 kg CO2e for high-field (3T) systems when full life cycle impacts are included. In contrast, IUS produces only 0.5-1.5 kg CO2e per scan, with minimal energy demand and negligible waste. IUS enables point-of-care assessments, reducing patient travel and associated emissions. CONCLUSION: GI endoscopy, CT and MRI are indispensable in IBD care but carry considerable environmental costs. The broader adoption of IUS offers a clinically effective, low-carbon alternative that can contribute to more sustainable IBD management, aligning with planetary health goals. TRIAL REGISTRATION: PROSPERO International Prospective Register of Systematic Reviews: CRD420251088016.
引用
- Massironi S, Zilli A, Furfaro F, et al. Systematic Review: Ultrasound Goes Echo-Decarbonising Inflammatory Bowel Disease Care Through Intestinal Ultrasound. Aliment Pharmacol Ther. 2025. PMID: 40985233. doi:10.1111/apt.70385
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。