文献速递肝病消化内镜

脾脏专用100Hz瞬时弹性成像预测高风险食管静脉曲张的诊断准确性

Diagnostic Accuracy of Spleen-Dedicated 100 Hz Transient Elastography to Predict High-Risk Esophageal Varices.
PubMed 文献 · Am J Gastroenterol · 2025-08-22

这项单中心前瞻性研究纳入116例肝硬化患者,评估脾脏专用100Hz瞬时弹性成像测量的脾硬度(SSM)预测高风险食管静脉曲张(HREV)和临床显著门脉高压(CSPH)的性能。SSM单独预测HREV的AUC为0.849,以35kPa为 cut-off 在代偿期肝硬化中灵敏度达95.6%,ssm单独可节省44.8%内镜检查,HREV漏诊率6.1%,低于Baveno VII标准的15.1%。

要点

  • 脾脏专用100Hz TE测量的SSM预测HREV的AUC为0.849,优于LSM单独(0.683)。
  • SSM 35kPa在代偿期肝硬化中排除HREV的灵敏度为95.6%。
  • SSM单独节省内镜44.8%,HREV漏诊率6.1%,优于Baveno VII的15.1%。

核心结论

  • SSM单独可准确预测肝硬化患者的高风险食管静脉曲张,并与LSM和血小板计数联合精确预测CSPH,显著减少内镜检查数量。

研究设计与样本

  • 单中心前瞻性研究,纳入116例肝硬化患者(97例代偿期,19例再代偿期),所有参与者接受内镜检查、脾脏专用100Hz瞬时弹性成像和实验室检查。

主要发现

  • 116例患者中33例(28.4%)存在HREV。
  • SSM、LSM单独、LSM联合血小板计数(PC)、LSM联合PC和SSM的AUC分别为0.849、0.683、0.808、0.864。
  • 代偿期肝硬化中SSM cut-off 35kPa的灵敏度为95.6%。
  • SSM单独节省内镜44.8%,而Baveno VI标准(LSM+PC)节省21.5%。
  • SSM单独HREV漏诊率6.1%,Baveno VII HREV标准漏诊率15.1%。

关键数值与推荐

  • SSM预测HREV的AUC为0.849。
  • 代偿期肝硬化SSM 35kPa排除HREV的灵敏度为95.6%。
  • SSM单独内镜节省率44.8%,HREV漏诊率6.1%。
  • Baveno VI标准(LSM+PC)内镜节省率21.5%。
  • Baveno VII HREV标准漏诊率15.1%。

临床怎么用

  • 脾脏专用100Hz TE测量的SSM可用于肝硬化患者排除HREV,减少内镜检查需求。
  • SSM联合LSM和血小板计数可精确预测CSPH并缩小灰区。
  • 排除HREV的SSM cut-off可能因病因不同而异。

局限性

  • 单中心研究,样本量116例。
  • 排除HREV的SSM cut-off可能随病因变化。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The Baveno VII consensus suggested different splenic stiffness measurement (SSM) cut-offs to predict High-Risk Esophageal Varices (HREV) and clinically significant portal hypertension (CSPH) in patients with cirrhosis. Few studies have validated these cut-offs using spleen-dedicated 100 Hz transient elastography (TE). We have assessed the diagnostic performance of SSM in predicting HREV and CSPH using a spleen-dedicated 100 Hz TE and compared it with other noninvasive algorithms. METHODS: This is a single-centre prospective study including patients with cirrhosis. Endoscopy, spleen-dedicated TE, and laboratory investigations were performed for all participants. A new SSM cut-off to rule out HREV was derived from our cohort. Its performance was compared with existing algorithms by determining endoscopy spare rate and HREV miss rate. The cut-offs suggested by the Baveno VII consensus for predicting HREV and CSPH were compared with the new SSM cut-off value. RESULTS: HREV were present in 33 (28.4%) of 116 patients (97 compensated and 19 recompensated cirrhosis). The Area under Receiver Operating Curve of SSM, liver stiffness measurement (LSM) alone, combination of LSM and platelet count (PC), and combination of LSM, PC, and SSM were 0.849, 0.683, 0.808, and 0.864, respectively. An SSM cut-off value of 35 kPa in compensated cirrhosis had a corresponding sensitivity of 95.6%. On extrapolating this cut-off in the overall cohort, SSM alone spared more endoscopies as compared with the Baveno VI criteria combining LSM and PC (44.8% vs 21.5%) and had a lower HREV miss rate as compared with the Baveno VII criteria for HREV (6.1% vs 15.1%). The combination of LSM, PC, and SSM narrowed the gray zone of CSPH to 12.9% when the single value of SSM cut-off derived from this study (35 kPa) was used. DISCUSSION: SSM alone can accurately predict HREV in cirrhosis, and its combination with LSM and PC precisely predicted CSPH, saving a significant number of endoscopies. The SSM cut-off to rule out HREV may vary with etiology.

来源:Am J Gastroenterol,查看原文。版权归原作者所有。

引用

  1. Prakash JH, Anirvan P, Gupta S, et al. Diagnostic Accuracy of Spleen-Dedicated 100 Hz Transient Elastography to Predict High-Risk Esophageal Varices. Am J Gastroenterol. 2025. PMID: 40844510. doi:10.14309/ajg.0000000000003741

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。