文献速递炎症性肠病胃肠动力与功能性疾病

可穿戴设备识别活动性炎症性肠病中睡眠特征及睡眠轨迹的改变

Wearable Devices Identify Altered Sleep Characteristics and Sleep Trajectories in Active Inflammatory Bowel Disease.
PubMed 文献 · Clin Gastroenterol Hepatol · 2025-06-26

该观察性研究纳入101例接受药物治疗的炎症性肠病成人患者,通过可穿戴设备采集睡眠结构、睡眠效率和总睡眠时长,并结合每日疾病活动问卷及标准诊疗中的炎症标志物进行分析。结果显示,活动性炎症与快速眼动睡眠占比显著降低、浅睡眠占比升高相关,且睡眠结构改变仅见于炎症存在时而非单纯症状发作时;炎症和症状发作前后45天内深睡眠与浅睡眠占比变化速率存在显著差异。

要点

  • 活动性炎症与快速眼动睡眠占比降低、浅睡眠占比升高相关。
  • 睡眠结构改变仅见于炎症存在时,单纯症状发作不影响睡眠质量。
  • 炎症和症状发作前后45天内深睡眠与浅睡眠占比变化速率存在显著差异。

核心结论

  • 睡眠结构受损与炎症性肠病中的炎症活动相关,单纯症状发作不影响睡眠质量。

研究设计与样本

  • 观察性研究,纳入101例≥18岁、已确诊并接受药物治疗的炎症性肠病患者,回答每日疾病活动问卷并佩戴可穿戴设备。
  • 从设备收集睡眠结构、睡眠效率和总睡眠时长,炎症标志物按标准诊疗采集。
  • 将睡眠指标与症状性发作、炎症性发作及两者组合期间进行关联比较,对照症状和炎症缓解期。
  • 探索炎症和症状发作前后45天内睡眠指标的变化速率。

主要发现

  • 共101例参与者入组,提供平均228.16 ± 154.24晚的可穿戴设备数据。
  • 活动性炎症期间与快速眼动睡眠时间占比显著降低及浅睡眠时间占比升高相关。
  • 评估炎症与症状发作的交集时,睡眠结构改变仅在炎症存在时明显,单纯症状发作时不明显。
  • 深睡眠和浅睡眠时间占比在炎症和症状发作前后45天内的变化速率存在显著差异。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND & AIMS: Poor sleep is associated with flares of inflammatory bowel disease (IBD). Studies often rely on subjective assessments of sleep and disease activity. Our aim is to use wearable devices to objectively assess the impact of inflammation and symptoms on sleep architecture in IBD. METHODS: Individuals ≥18 years of age, diagnosed with and on medication for IBD, were enrolled in an observational study, answered daily disease activity surveys, and wore a wearable device. Sleep architecture, sleep efficiency, and total hours asleep were collected from the devices. Inflammatory markers were collected as standard of care. Associations between sleep metrics and periods of symptomatic and inflammatory flares and combinations of symptomatic and inflammatory activity were compared with periods of symptomatic and inflammatory remission. The rate of change in sleep metrics for 45 days before and after inflammatory and symptomatic flares was explored. RESULTS: A total of 101 participants were enrolled contributing a mean duration of 228.16 ± 154.24 nights of wearable data. Periods with active inflammation were associated with a significantly smaller percentage of sleep time in rapid eye movement and a greater percentage of sleep time in light sleep. Evaluating the intersection of inflammatory and symptomatic flares, altered sleep architecture was only evident when inflammation was present, and not with symptoms. Significant differences were observed in the rate that the percentage of time spent in deep and light sleep changed before and after inflammatory and symptomatic flares. CONCLUSIONS: Impaired sleep architecture is associated with inflammatory activity in IBD, and the presence of symptomatic flares alone does not impact sleep quality.

来源:Clin Gastroenterol Hepatol,查看原文。版权归原作者所有。

引用

  1. Hirten RP, Danieletto M, Whang JK, et al. Wearable Devices Identify Altered Sleep Characteristics and Sleep Trajectories in Active Inflammatory Bowel Disease. Clin Gastroenterol Hepatol. 2025. PMID: 40581072. doi:10.1016/j.cgh.2025.06.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。