磁控柔性内镜:1期首次人体临床试验
本研究为1期首次人体试验,纳入5例计划行筛查性结肠镜检查的患者,在标准结肠镜检查退出、停止镇静后,将磁控柔性内镜(MFE)经肛门置入未镇静患者的结肠并推进。所有患者均清醒配合、耐受良好,无不适、疼痛或其他主诉,无不良事件或创伤,系统运行稳定无软件或功能故障。
要点
- 5例患者均成功完成标准结肠镜检查,随后在未镇静状态下接受MFE结肠检查。
- 所有患者清醒警觉,耐受良好,无不适、疼痛或其他主诉,无不良事件或创伤。
- 系统运行稳定,无软件或功能故障,无预期外事件。
核心结论
- MFE成功通过人体结肠,无不良事件或患者不适,系统性能成功且无预期外事件。
- 这是该新型平台首次在体内展示安全性和耐受性。
研究设计与样本
- 1期首次人体临床试验,纳入5例计划行筛查性结肠镜检查(ICD-10 z12.11)的患者。
- 患者先接受监测麻醉护理下的标准结肠镜检查,退出结肠镜时停止镇静,拔镜后将MFE经肛门置入结肠,在未镇静状态下推进,通过结肠后退出。
- 观察指标包括MFE的安全性和耐受性、结构化访谈的患者感受、平台可用性和机器人位姿数据。
主要发现
- 所有患者均成功完成标准结肠镜检查。
- 所有患者在接受MFE结肠镜检查时均清醒警觉,耐受良好,无不适、疼痛或其他主诉。
- 无不良事件或创伤。
- 系统运行稳定,无软件或功能故障。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Magnetic actuation of endoscopes is promising-as the endoscope can be pulled from its front. Our team developed a novel magnetic flexible endoscope (MFE) that uses magnetic field sensing, robotic control, and real-time image processing for colonoscopy. We conducted a Phase 1 first-in-human clinical trial to assess platform safety and tolerability. METHODS: Platform: The MFE contains an internal permanent magnet, camera, illumination module, and channels for instruments, insufflation/camera cleaning, irrigation, and suction. A robotic arm maneuvers a second permanent magnet coupled to the MFE. System software facilitates controlled intelligent magnetic actuation. Experiment: 5 patients scheduled for screening colonoscopy ( ICD-10 z12.11) were enrolled. Patients underwent standard of care colonoscopy with monitored anesthesia care. On withdrawal of the colonoscope, sedation was stopped, and after colonoscope removal, the MFE was inserted into the colon through the anus. The MFE was advanced through the colon while the patient was unsedated. After colon traversal, the MFE was withdrawn. Outcomes of interest included safety and tolerability of the MFE, participant sentiment through structured interview, platform usability, and robot pose data. RESULTS: All patients underwent successful standard of care colonoscopy. All patients were awake and alert for MFE colonoscopy, tolerating the examination well without discomfort, pain, or other complaint. There were no adverse events or trauma. The system was robust without software or function failure. DISCUSSION: The MFE successfully traversed the human colon without adverse event or patient discomfort. System performance was successful without unanticipated events. This is the first-time safety and tolerability of the novel platform has been demonstrated in vivo .
引用
- Obstein KL, Landewee CA, Martin J, et al. The Magnetic Flexible Endoscope: Phase 1 First-in-Human Clinical Trial. Am J Gastroenterol. 2025. PMID: 40493042. doi:10.14309/ajg.0000000000003584
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。