该系统综述检索EMBASE、Scopus和PubMed至2024年11月,分析Roux-en-Y胃旁路术后行EUS引导经胃ERCP(EDGE)患者持续瘘(PF)与技术因素的关系。398例接受客观检测的患者中78例(19.6%)存在PF;较大支架(20 mm vs 15 mm)、被动(自发)闭合及较长支架留置时间似乎与PF风险增加相关。
要点
- 398例EDGE后客观检测患者中78例(19.6%)存在持续瘘。
- 20 mm支架较15 mm支架与PF风险增加相关(RR 1.65)。
- 被动闭合较主动闭合与PF风险增加相关(RR 7.25)。
核心结论
- 较大支架尺寸、支架移除后被动(自发)闭合及较长支架留置时间似乎与EDGE后PF形成风险增加相关。
研究设计与样本
- 系统综述,检索EMBASE、Scopus和PubMed数据库自建库至2024年11月。
- 两名作者独立提取可能与PF相关的技术因素数据,分歧通过共识解决。
主要发现
- 398例EDGE后接受客观检测的患者中,78例(19.6%)存在PF。
- 瘘口位置(胃胃 vs 空肠胃)与PF无关联(相对风险1.16;95%CI 0.93-1.41;P=.14)。
- ERCP在造瘘时或之后进行与PF无关联(相对风险1.03;95%CI 0.66-1.70;P=.99)。
- 使用较大内腔并置金属支架(20 mm vs 15 mm)与PF相关(相对风险1.65;95%CI 1.02-2.72;P=.022)。
- 支架移除后被动(自发)闭合较主动闭合与PF形成相关(相对风险7.25;95%CI 1.08-192.5;P=.020)。
关键数值与推荐
- 支架留置时间与PF的关联经Wilcoxon符号秩和检验无统计学意义(P=.13),但经加权配对t检验有统计学意义(P=.04)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: An important unintended consequence of EUS-directed transgastric ERCP (EDGE) in patients with Roux-en-Y gastric bypass is persistent fistula (PF) formation after stent removal. To better inform procedural decision-making, we wanted to elucidate the technical factors associated with PF after EDGE. METHODS: We performed a systematic literature search of EMBASE, Scopus, and PubMed databases from inception until November 2024. Two authors independently extracted data on technical factors potentially associated with PF. Discrepancies were resolved by consensus. The association between PF and selected technical characteristics was evaluated. RESULTS: Of 398 patients who underwent objective testing after EDGE, 78 (19.6%) had PF. There did not appear to be an association between PF and location of the fistula (gastrogastric vs jejunogastric) (relative risk, 1.16; 95% CI, 0.93-1.41; P = .14) or whether ERCP was performed at the time of fistula creation or later (relative risk, 1.03; 95% CI, 0.66-1.70; P = .99). The use of a larger lumen-apposing metal stent (20 mm vs 15 mm) did appear to be associated with PF (relative risk, 1.65; 95% CI, 1.02-2.72; P = .022). Passive (spontaneous) fistula closure after stent removal was also associated with PF formation relative to active closure (relative risk, 7.25; 95% CI, 1.08-192.5; P = .020). The association between stent dwell time and PF was not statistically significant according to the Wilcoxon signed rank sum test (P = .13) but was significant by the weighted paired t test (P = .04). CONCLUSIONS: In this systematic review, larger stent size, passive (spontaneous) closure after stent removal, and longer stent dwell time appeared to be associated with an increased risk of PF formation after EDGE.
引用
- Esckilsen S, Sagatelian M, Nietert PJ, et al. Systematic review of technical factors associated with persistent fistula after EUS-directed transgastric ERCP in patients with Roux-en-Y gastric bypass. Gastrointest Endosc. 2025. PMID: 40210021. doi:10.1016/j.gie.2025.03.1331