内镜联合功能性腔镜成像探针测压法可加速食管动力障碍诊断
本研究纳入224例完成上消化道内镜、FLIP测压及高分辨率测压的成人患者,评估内镜动力评分(CARS)联合FLIP测压分类诊断食管动力障碍的效能,以HRM和芝加哥分类v4.0为参考标准。CARS评分0-1且FLIP测压EGJ开放正常者均无贲门失弛缓症或确定性EGJOO(阴性预测值100%),CARS评分≥4且FLIP测压为非痉挛性梗阻者均为贲门失弛缓症或确定性EGJOO(阳性预测值97%)。
要点
- CARS评分0-1且FLIP测压EGJ开放正常者,均无贲门失弛缓症或确定性EGJOO,阴性预测值100%。
- CARS评分≥4且FLIP测压为非痉挛性梗阻者,均为贲门失弛缓症或确定性EGJOO,阳性预测值97%。
- CARS与FLIP其他组合者中49%有贲门失弛缓症或确定性EGJOO,需进一步检查。
核心结论
- 内镜CARS评分联合FLIP测压可在镇静内镜操作中识别需要处理的食管动力障碍,该方法耐受良好并弥补HRM的局限。
- 作者认为该策略有望加速管理,部分患者可减少HRM需求,另一些则转向额外检查。
- 原文提到计划进一步验证。
研究设计与样本
- 研究纳入完成上消化道内镜、FLIP测压和高分辨率测压的成人患者,共224例,平均年龄52±18岁,女性51%。
- 回顾内镜视频计算CARS评分,应用FLIP测压的EGJ开放和收缩特征得出动力分类,以HRM和芝加哥分类v4.0为参考标准。
主要发现
- 224例中112例(50%)按HRM和CCv4.0诊断为贲门失弛缓症或确定性EGJOO。
- CARS评分0-1且FLIP测压EGJ开放正常的63例中,无一例为贲门失弛缓症或确定性EGJOO,阴性预测值100%。
- CARS评分≥4且FLIP测压分类为非痉挛性梗阻的65例中,65例均为贲门失弛缓症或确定性EGJOO,其中63例为非痉挛性,阳性预测值97%。
- 其他CARS/FLIP组合的96例(占224例的43%)中,47例(49%)为贲门失弛缓症或确定性EGJOO。
关键数值与推荐
- CARS评分0-1且FLIP测压EGJ开放正常:阴性预测值100%。
- CARS评分≥4且FLIP测压为非痉挛性梗阻:阳性预测值97%。
临床怎么用
- 原文结论认为,将内镜CARS评分与FLIP测压联合应用于指数内镜操作,可加速管理,部分患者可减少HRM需求,另一些则转向额外检查。
局限性
- 原文提到计划进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Upper endoscopy and functional lumen imaging probe (FLIP) panometry offer a complementary approach to diagnose esophageal motility disorders during the sedated endoscopy encounter. This study aimed to evaluate an approach combining an endoscopic motility score and FLIP panometry to diagnosis esophageal motility disorders. METHODS: Adult patients who completed upper endoscopy with FLIP and high-resolution manometry (HRM) were included. Endoscopic videos were reviewed to determine the Contents, Anatomy, Resistance, Stasis (CARS) score. Esophagogastric junction (EGJ) opening and contractility profile were applied to derive a FLIP panometry motility classification. HRM and Chicago Classification version 4.0 (CCv4.0) were used as the reference standard. RESULTS: A total of 224 patients (mean age, 52 ± 18 years; 51% female) were included; 112 (50%) had achalasia or conclusive EGJ outflow obstruction (EGJOO) according to HRM and CCv4.0. None of 63 patients with CARS score 0 to 1 and normal EGJ opening on FLIP panometry had achalasia/conclusive EGJOO (100% negative predictive value); 65 of 65 patients with CARS score ≥4 and FLIP panometry classifications of nonspastic obstruction (n = 65) had achalasia or conclusive EGJOO, which was nonspastic in 63 (97% positive predictive value). Of the 96 of 224 (43%) patients with other CARS/FLIP combinations, 47 (49%) had achalasia or conclusive EGJOO. CONCLUSIONS: An approach using endoscopy (CARS score) and FLIP panometry (endoscopy with FLIP panometry [mechanics, anatomy, physiology]) identified actionable esophageal motility disorders at the point-of-care endoscopy encounter. While additional validation is planned, this approach offers a well tolerated method that addresses limitations of HRM. Applied to the index endoscopic encounter, this approach could expedite management, reducing need for HRM in some patients versus triaging toward additional testing in others.
引用
- Carlson DA, Li M, Fass O, et al. A combined endoscopy and functional lumen imaging probe panometry approach can expedite diagnosis of esophageal motility disorders. Gastrointest Endosc. 2025. PMID: 40210016. doi:10.1016/j.gie.2025.03.1329
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。