文献速递肝病消化内镜

三维经颈静脉肝内门体分流术几何形态预测分流功能障碍

Three-Dimensional Transjugular Intrahepatic Portosystemic Shunt Geometry Predicts Shunt Dysfunction.
PubMed 文献 · Aliment Pharmacol Ther · 2025-04-09

本研究纳入2014至2019年接受经颈静脉肝内门体分流术(TIPS)并在术后行CT检查的107例患者,利用半自动算法和多平面重建计算三维TIPS几何参数,以Cox回归分析预测TIPS功能障碍(需侵入性TIPS修正)。32例发生功能障碍,多因素分析显示支架颅端至下腔静脉距离较大(p<0.001,HR 1.061,95%CI 1.030-1.093)和最大支架弯曲度(p=0.003,HR 1.020,95%CI 1.007-1.034)与TIPS功能障碍显著相关。

要点

  • 支架颅端至下腔静脉距离较大与TIPS功能障碍独立相关(HR 1.061)。
  • 最大支架弯曲度较大与TIPS功能障碍独立相关(HR 1.020)。
  • 作者建议介入医生在TIPS术中选用更居中、弯曲更少的通路。

核心结论

  • 更明显的支架弯曲度和支架颅端距下腔静脉更长的距离被确定为TIPS功能障碍的独立预测因素。
  • 作者建议介入医生在TIPS术中选用更居中且弯曲更少的TIPS通路以降低TIPS功能障碍风险。

研究设计与样本

  • 回顾性单中心研究,纳入NEPTUN队列(ClinicalTrials.gov注册号NCT03628807)中2014至2019年接受TIPS插入并在常规临床实践中术后行CT扫描的107例患者。
  • 使用半自动算法和多平面重建CT扫描计算三维TIPS几何参数。
  • 主要结局为TIPS功能障碍(定义为需侵入性TIPS修正),采用Cox回归分析识别预测因素。

主要发现

  • 32例患者发生TIPS功能障碍,与75例无功能障碍患者进行比较。
  • 多因素Cox回归分析显示,支架颅端至下腔静脉距离较大与TIPS功能障碍显著相关(p<0.001,HR 1.061,95%CI 1.030-1.093)。
  • 多因素Cox回归分析显示,最大支架弯曲度与TIPS功能障碍显著相关(p=0.003,HR 1.020,95%CI 1.007-1.034)。

临床怎么用

  • 作者建议介入医生在TIPS术中选用更居中且弯曲更少的TIPS通路以降低TIPS功能障碍风险。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Patients with decompensated cirrhosis are at risk of portal hypertension-related complications, such as refractory ascites or variceal bleeding. Transjugular intrahepatic portosystemic shunt (TIPS) insertion is the most effective treatment to reduce portal hypertension. However, patients are at risk for TIPS dysfunction. AIMS: We aimed to investigate the prognostic value of three-dimensional (3D) TIPS geometry in predicting TIPS dysfunction. METHODS: A total of 107 patients who underwent TIPS insertion between 2014 and 2019 and received a computed tomography (CT) scan after TIPS insertion during routine clinical practice were included. We used a semiautomated algorithm and multiplanar reconstructions of these CT scans to calculate parameters of 3D TIPS geometry. The primary outcome of this study was the development of TIPS dysfunction (defined as need for invasive TIPS revision). To identify predictors for the development of TIPS dysfunction, Cox regression analyses were performed with TIPS dysfunction as the endpoint. RESULTS: Thirty-two patients developed TIPS dysfunction and were compared to the dysfunction-free 75 patients. A larger distance from the cranial TIPS stent end to the vena cava inferior (p < 0.001, HR 1.061, 95% CI 1.030-1.093) and the maximum stent curvature (p = 0.003, HR 1.020, 95% CI 1.007-1.034) were significantly associated with TIPS dysfunction in a multivariate Cox regression analysis. CONCLUSION: A more pronounced stent curvature and a longer cranial stent distance from the inferior vena cava were identified as independent predictors of TIPS dysfunction. Interventionalists should choose a more central and less curved TIPS tract during the TIPS procedure to reduce the risk of development of TIPS dysfunction. TRIAL REGISTRATION: This retrospective monocentric study includes patients from the NEPTUN cohort (registered at ClinicalTrials.gov; Identifier: NCT03628807).

来源:Aliment Pharmacol Ther,查看原文。版权归原作者所有。

引用

  1. Meyer C, Kimmann M, Böhm K, et al. Three-Dimensional Transjugular Intrahepatic Portosystemic Shunt Geometry Predicts Shunt Dysfunction. Aliment Pharmacol Ther. 2025. PMID: 40202365. doi:10.1111/apt.70133

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。