文献速递胰腺与胆道疾病消化内镜

胆道自膨式金属支架置入导致内镜逆行胰胆管造影术后胰腺炎的风险:单中心回顾性研究

Risk of post-endoscopic retrograde cholangiopancreatography pancreatitis due to placement of biliary self-expandable metal stents: a single-center retrospective study.
PubMed 文献 · Gastrointest Endosc · 2025-03-26

该单中心回顾性研究纳入2016至2021年接受ERCP的1718例连续患者,比较置入与未置入自膨式金属支架(SEMS)者的PEP发生率。SEMS组PEP发生率高于非SEMS组(10.6% vs 5.7%,P = .0008),多因素分析显示SEMS置入与PEP风险独立相关(调整OR 2.30,95%CI 1.48-3.56,P = .0002)。

要点

  • SEMS组PEP发生率为10.6%,非SEMS组为5.7%(P = .0008)。
  • 置入塑料支架者PEP发生率为10.6%(31/494),未置入者为6.3%(P = .0299)。
  • 多因素分析显示SEMS置入与PEP风险独立相关(调整OR 2.30,95%CI 1.48-3.56)。

核心结论

  • 本中心发现SEMS置入是ERCP术后胰腺炎发生的独立危险因素。

研究设计与样本

  • 单中心回顾性研究,纳入2016至2021年在本机构接受ERCP的1718例连续患者,分为SEMS组(21%,n = 358)和非SEMS组。

主要发现

  • SEMS组PEP发生率高于非SEMS组(10.6% vs 5.7%,P = .0008)。
  • 置入塑料支架者PEP发生率为10.6%(31/494),未置入塑料支架者为6.3%(P = .0299)。
  • 多因素logistic回归分析显示,SEMS置入与PEP风险增加独立相关(调整OR 2.30,95%CI 1.48-3.56,P = .0002)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Post-endoscopic retrograde cholangiopancreatography (ERCP) pancreatitis (PEP) is the most common adverse event after ERCP. Placement of self-expandable metal stents (SEMSs) is common during ERCP. We investigated whether SEMS placement during ERCP increases the risk for PEP. METHODS: We conducted a retrospective study on patients who underwent ERCP at our institution from 2016 to 2021. Patients were divided into those with SEMSs and those without SEMSs. The PEP rates were compared between the 2 groups. We used a multivariable logistic regression model to assess the strength of the association between the primary outcome (PEP) and its predictor (SEMS placement) while controlling for potential confounders such as procedure indication, indomethacin use, native papilla, and pancreatic duct manipulation and/or stent placement. RESULTS: Of 1718 consecutive patients included in the study, 21% (n = 358) had SEMS placement. PEP was higher in the SEMS group than in the non-SEMS group (10.6% vs 5.7%, P = .0008) and in those who had plastic stent placement (31/494; 10.6% vs 6.3%, P = .0299). On multivariable logistic regression analysis, SEMS placement was independently associated with a 2.3-fold increased risk of PEP (adjusted odds ratio, 2.30; 95% CI, 1.48-3.56; P = .0002). CONCLUSIONS: At our center, SEMS placement was found to be an independent risk factor for the development of PEP.

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Radetic M, Ladna M, Shen S, et al. Risk of post-endoscopic retrograde cholangiopancreatography pancreatitis due to placement of biliary self-expandable metal stents: a single-center retrospective study. Gastrointest Endosc. 2025. PMID: 40154810. doi:10.1016/j.gie.2025.03.1212

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。