文献速递肝病

质子密度脂肪分数用于诊断代谢功能障碍相关脂肪性肝病

Proton density fat fraction for diagnosis of metabolic dysfunction-associated steatotic liver disease.
PubMed 文献 · Hepatology · 2025-03-25

本研究以接受减重手术的肥胖成人为对象,以术中肝活检为参考,评估MRI质子密度脂肪分数(PDFF)诊断代谢功能障碍相关脂肪性肝病(MASLD)、代谢功能障碍相关脂肪性肝炎(MASH)和纤维化MASH的效能。140例患者中PDFF是单指标中最准确的,MASLD、MASH和纤维化MASH的AUC分别为0.95、0.85和0.82(均p<0.001),基于Youden指数的阈值分别为4.4%、6.9%和13.5%。

要点

  • PDFF诊断MASLD的AUC为0.95,阈值4.4%时敏感度87%、特异度86%。
  • PDFF诊断MASH的AUC为0.85,阈值6.9%时敏感度77%、特异度66%。
  • PDFF诊断纤维化MASH的AUC为0.82,阈值13.5%时敏感度67%、特异度85%。

核心结论

  • PDFF是诊断MASLD、MASH和纤维化MASH最准确的单指标。
  • 纳入PDFF的多变量分类模型对MASLD、MASH和纤维化MASH最为准确,提示PDFF在无创评估MASLD谱系中具有核心重要性。

研究设计与样本

  • 研究纳入接受减重手术的肥胖成人140例,以同期术中肝活检为参考标准。
  • 采用基于贝叶斯信息准则的逐步logistic回归模型,评估PDFF单独及联合其他影像、血清和人体测量指标的分类效能。

主要发现

  • PDFF诊断MASLD的AUC为0.95,MASH为0.85,纤维化MASH为0.82,均p<0.001。
  • 包含PDFF的多变量模型优于不含PDFF的模型。
  • 基于Youden指数的PDFF阈值:MASLD为4.4%(敏感度87%,特异度86%),MASH为6.9%(敏感度77%,特异度66%),纤维化MASH为13.5%(敏感度67%,特异度85%)。

关键数值与推荐

  • PDFF诊断MASLD的AUC为0.95(p<0.001),阈值4.4%时敏感度87%、特异度86%。
  • PDFF诊断MASH的AUC为0.85(p<0.001),阈值6.9%时敏感度77%、特异度66%。
  • PDFF诊断纤维化MASH的AUC为0.82(p<0.001),阈值13.5%时敏感度67%、特异度85%。

临床怎么用

  • 原文未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Prior work has shown that MRI-derived proton density fat fraction (PDFF) can diagnose metabolic dysfunction-associated steatotic liver disease (MASLD) noninvasively, but there is a paucity of data on the performance of PDFF to classify more advanced forms of the MASLD spectrum. The purpose of this study was to assess the diagnostic performance of PDFF for the diagnoses of MASLD, metabolic dysfunction-associated steatohepatitis (MASH), and fibrotic MASH in adults with obesity undergoing bariatric surgery, using contemporaneous intraoperative liver biopsy as a reference. APPROACH AND RESULTS: PDFF was evaluated alone and with other potential classifiers (imaging, serum and anthropometric), using Bayesian Information Criterion-based stepwise logistic regression models. Areas under the receiver operating characteristic (ROC) curves (AUC) were computed for all models and single classifiers. Cross-validated sensitivity and specificity were calculated at Youden-based PDFF classification thresholds. Data analysis from 140 patients demonstrated that PDFF was the most accurate single classifier, with high AUC for MASLD (0.95), MASH (0.85), and fibrotic MASH (0.82) (all p <0.001). Multivariable models, including PDFF, outperformed those without PDFF. The Youden-based threshold for PDFF was 4.4% for MASLD (sensitivity: 87%, specificity: 86%), 6.9% for MASH (sensitivity: 77%, specificity: 66%), and 13.5% for fibrotic MASH (sensitivity: 67%, specificity: 85%). CONCLUSIONS: PDFF was the most accurate single classifier for diagnosing MASLD, MASH, and fibrotic MASH. The most accurate multivariable classification models for MASLD, MASH, and fibrotic MASH included PDFF, demonstrating the central importance of PDFF for noninvasive assessment of the MASLD spectrum.

来源:Hepatology,查看原文。版权归原作者所有。

引用

  1. Panagiotopoulos N, Wolfson T, Harris DT, et al. Proton density fat fraction for diagnosis of metabolic dysfunction-associated steatotic liver disease. Hepatology. 2025. PMID: 40132140. doi:10.1097/HEP.0000000000001318

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。