线性阵列超声内镜诊断胰腺分裂优于磁共振胰胆管成像:东方人群多中心回顾性研究(附视频)
本多中心回顾性研究纳入2019年1月至2023年7月因胰胆管指征行线性阵列超声内镜(L-EUS)并随后接受内镜逆行胰管造影术(ERP)治疗的患者,以ERP为参考标准,比较L-EUS与磁共振胰胆管成像(MRCP)诊断胰腺分裂(PD)的准确性。共纳入3家三级中心的1378例患者,其中120例经ERP确诊PD,内镜检出率为8.7%。L-EUS诊断PD的敏感度和总体准确率均显著优于MRCP,但在存在胰管结石或重度胰腺炎时诊断可靠性下降。
要点
- L-EUS诊断PD的敏感度为90.8%,总体准确率为99%,均显著优于MRCP。
- MRCP诊断PD的敏感度为48.4%,准确率为95.4%,AUC为74.1%。
- 胰管结石(OR 5.627)和重度胰腺炎(OR 12.818)与L-EUS诊断PD失败风险升高相关。
核心结论
- 本研究表明L-EUS诊断PD显著优于MRCP,敏感度和AUC值明显更高,但在存在胰管结石或重度胰腺炎时诊断可靠性下降。
研究设计与样本
- 多中心回顾性研究,纳入2019年1月至2023年7月3家三级中心因胰胆管指征行L-EUS并随后接受ERP治疗的1378例患者。
- 以ERP为参考标准,其中120例确诊PD,内镜检出率为8.7%。
主要发现
- L-EUS诊断PD的敏感度为90.8%(95%CI 85.7%-96.0%),总体准确率为99%(95%CI 98.5%-99.5%)。
- MRCP诊断PD的敏感度为48.4%(95%CI 38.1%-58.6%),准确率为95.4%(95%CI 93.5%-96.3%),L-EUS与MRCP比较P<.001。
- L-EUS诊断PD的AUC为95.7%,MRCP为74.1%(P<.001)。
- 一致性检验显示L-EUS的kappa值为0.934,参考标准为0.621。
- 单因素logistic回归分析显示胰管结石、慢性胰腺炎和重度胰腺炎是L-EUS检测PD诊断失败的潜在因素。
关键数值与推荐
- 多因素logistic回归分析显示,胰管结石与L-EUS诊断PD失败风险升高相关(OR 5.627;95%CI 1.391-22.765)。
- 重度胰腺炎与L-EUS诊断PD失败风险升高相关(OR 12.818;95%CI 2.280-72.061)。
临床怎么用
- 作者认为L-EUS诊断PD显著优于MRCP,敏感度和AUC值明显更高,但存在胰管结石或重度胰腺炎时诊断可靠性下降。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Pancreas divisum (PD) is the most common developmental anatomic variant of pancreatic duct. The published data on the accuracy of the detection of PD by means of linear-array endoscopic ultrasound (L-EUS) are limited. This study aimed to assess the diagnostic accuracy of L-EUS compared with magnetic resonance cholangiopancreatography (MRCP) for identifying PD. METHODS: Patients who underwent L-EUS for pancreaticobiliary indications and subsequently received endoscopic retrograde pancreatograghy (ERP) treatment were retrospectively evaluated from January 2019 to July 2023. RESULTS: A total of 1378 patients from 3 tertiary centers were included, of which 120 were diagnosed with PD, as confirmed with the use of ERP, yielding an endoscopic detection rate of 8.7%. L-EUS exhibited a high sensitivity of 90.8% (95% confidence interval [CI], 85.7%-96.0%) and an overall accuracy of 99% (95% CI, 98.5%-99.5%) for the diagnosis of PD. These figures were significantly superior to those of MRCP, which showed a sensitivity of 48.4% (95% CI, 38.1%-58.6%) and an accuracy of 95.4% (95% CI, 93.5%-96.3%) (P < .001). Furthermore, the area under the receiver operating characteristic curve (AUC) for PD diagnosis was notably higher for L-EUS (95.7%) compared with MRCP (74.1%) (P < .001). Consistency testing revealed that L-EUS had an excellent kappa value of 0.934, compared with the reference standard of 0.621. Univariate logistic regression analysis identified the presence of pancreatic duct stones, chronic pancreatitis, and severe pancreatitis as potential factors leading to diagnostic failure in detecting PD with the use of L-EUS. Subsequent multivariate logistic regression analysis confirmed that the presence of pancreatic duct stones (odds ratio [OR], 5.627; 95% CI, 1.391-22.765) and severe pancreatitis (OR, 12.818; 95% CI, 2.280-72.061) were significantly associated with increased odds of L-EUS diagnostic failure for PD. CONCLUSIONS: Our study conclusively demonstrates that L-EUS significantly outperforms MRCP in diagnosing PD. L-EUS exhibits markedly higher sensitivity and AUC values. However, its diagnostic reliability decreases in the presence of pancreatic duct stones or severe pancreatitis.
引用
- Mao Y, Ni J, Peng K, et al. Superiority of linear-array EUS over MRCP in diagnosing pancreas divisum: evidence from a multicenter retrospective study in Oriental cohorts (with video). Gastrointest Endosc. 2024. PMID: 39732177. doi:10.1016/j.gie.2024.12.033
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。