双气囊小肠镜下经内镜通道导管超声评估小肠克罗恩病深度缓解
本研究评估双气囊小肠镜联合经内镜通道超声(DBE-EUS)区分小肠克罗恩病内镜缓解与活动的效果。活动组小肠全壁厚度和黏膜下层厚度均显著大于缓解组,全壁厚度与SES-CD、粪钙卫蛋白及CDAI呈正相关。DBE-EUS可同时评估黏膜愈合与透壁愈合。
要点
- 活动组全壁厚度3.84±1.02 mm大于缓解组2.42±0.25 mm(P<.001)。
- 全壁厚度2.65 mm区分活动与缓解的敏感度91.5%、特异度80.8%。
- 全壁厚度与SES-CD、粪钙卫蛋白及CDAI均呈正相关(P<.001)。
核心结论
- 双气囊小肠镜联合经内镜通道导管超声可有效评估小肠克罗恩病患者的黏膜愈合与透壁愈合。
- DBE-EUS可能成为小肠克罗恩病患者管理的重要工具。
研究设计与样本
- 接受DBE-EUS检查的患者根据节段性SES-CD分为内镜缓解组与内镜活动组。
- 采用超声导管探头评估小肠壁各层厚度及其他参数。
主要发现
- 活动组全壁厚度3.84±1.02 mm vs 缓解组2.42±0.25 mm,活动组显著大于缓解组(P<.001)。
- 活动组黏膜下层厚度1.23±0.34 mm vs 缓解组0.79±0.13 mm,活动组显著大于缓解组(P<.001)。
- 全壁厚度与SES-CD呈显著正相关(r=.930,P<.001)。
- 全壁厚度与粪钙卫蛋白呈强正相关(r=.861,P<.001),与克罗恩病活动指数呈强正相关(r=.805,P<.001)。
- 黏膜下层厚度观察到类似结果。
关键数值与推荐
- 全壁厚度截断值2.65 mm区分活动性与非活动性小肠克罗恩病,敏感度91.5%、特异度80.8%。
- 黏膜下层厚度截断值0.95 mm区分活动性与非活动性小肠克罗恩病,敏感度70.2%、特异度88.6%。
临床怎么用
- 原文结论认为DBE-EUS可有效评估小肠克罗恩病的黏膜与透壁愈合,可能成为患者管理的重要工具。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Evaluation of deep remission in Crohn's disease (CD) can be challenging when the disease is confined to the small intestine. The aim of this study was to evaluate the effectiveness of through-the-scope EUS during double-balloon enteroscopy (DBE-EUS) in distinguishing small-bowel CD patients in endoscopic remission from those with active disease. METHODS: Patients who underwent DBE-EUS were divided into groups of endoscopic remission and endoscopic activity according to segmental Simple Endoscopic Score for Crohn's Disease (SES-CD). The thickness of small intestinal wall layers and other parameters were evaluated by EUS. RESULTS: EUS using an ultrasonic catheter probe by DBE showed that the total wall thickness (TWT) and submucosal thickness (SMT) of the small intestine in the active group were significantly greater than those in the remission group (3.84 ± 1.02 mm vs 2.42 ± .25 mm and 1.23 ± .34 mm vs .79 ± .13 mm, respectively; P < .001). Cutoff values of 2.65 mm for TWT and .95 mm for SMT can distinguish active small-bowel CD from inactive disease (sensitivity 91.5% and specificity 80.8% and sensitivity 70.2% and specificity 88.6%, respectively). The correlation analysis revealed a significant positive correlation between TWT and SES-CD (r =.930, P < .001). Furthermore, TWT was strongly correlated with fecal calprotectin (r = .861, P < .001) and Crohn's Disease Activity Index (r = .805, P < .001). Similar results were observed for SMT. CONCLUSIONS: EUS using an ultrasonic catheter probe during DBE is effective in evaluation of both mucosal and transmural healing in small-bowel CD patients. DBE-EUS could become an important tool in the management of patients with small-bowel CD.
引用
- Hu J, Li G, Han W, et al. Evaluation of deep remission with through-the-scope catheter-based EUS during double-balloon enteroscopy in small-bowel Crohn's disease. Gastrointest Endosc. 2024. PMID: 39490689. doi:10.1016/j.gie.2024.10.037
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。