结肠镜检查中计算机辅助诊断的准确性因息肉位置而异:系统综述与Meta分析
该系统综述与Meta分析纳入11项研究共7782枚≤5 mm息肉,评估实时计算机辅助诊断(CADx)独立预测组织学的性能。近端结肠CADx特异度显著低于远端(62% vs 85%;RR 0.74;95%CI 0.72-0.84),敏感度相似(89% vs 87%;RR 1.00;95%CI 0.97-1.03)。结论认为近端结肠CADx诊断性能不足,在开发出更高效系统前不应用于近端息肉。
要点
- 近端结肠CADx特异度显著低于远端(62% vs 85%;RR 0.74;95%CI 0.72-0.84)。
- 近端与远端敏感度相似(89% vs 87%;RR 1.00;95%CI 0.97-1.03)。
- 近端结肠NPV和准确率显著低于远端,PPV高于远端。
核心结论
- 近端结肠CADx诊断性能不足,特异度显著低于远端息肉;现有CADx系统适用于远端结肠,在开发出针对近端病变的更高效系统前不应用于近端息肉。
研究设计与样本
- 系统综述与Meta分析,纳入11项评估实时CADx独立预测≤5 mm结直肠息肉组织学性能的研究,共7782枚息肉。
主要发现
- 近端结肠CADx特异度62% vs 远端85%(RR 0.74;95%CI 0.72-0.84)。
- 近端结肠敏感度89% vs 远端87%(RR 1.00;95%CI 0.97-1.03)。
- 近端结肠NPV 64% vs 远端93%(RR 0.71;95%CI 0.64-0.79)。
- 近端结肠准确率81% vs 远端86%(RR 0.95;95%CI 0.91-0.99)。
- 近端结肠PPV 87% vs 远端76%(RR 1.11;95%CI 1.06-1.17)。
临床怎么用
- 作者认为现有CADx系统适用于远端结肠,但在开发出针对近端病变的更高效系统前不应用于近端息肉。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND & AIMS: Computer-aided diagnosis (CADx) assists endoscopists in differentiating between neoplastic and non-neoplastic polyps during colonoscopy. This study aimed to evaluate the impact of polyp location (proximal vs. distal colon) on the diagnostic performance of CADx for ≤5 mm polyps. METHODS: We searched for studies evaluating the performance of real-time CADx alone (ie, independently of endoscopist judgement) for predicting the histology of colorectal polyps ≤5 mm. The primary endpoints were CADx sensitivity and specificity in the proximal and distal colon. Secondary outcomes were the negative predictive value (NPV), positive predictive value (PPV), and the accuracy of the CADx alone. Distal colon was limited to the rectum and sigmoid. RESULTS: We included 11 studies for analysis with a total of 7782 polyps ≤5 mm. CADx specificity was significantly lower in the proximal colon compared with the distal colon (62% vs 85%; risk ratio (RR), 0.74; 95% confidence interval [CI], 0.72-0.84). Conversely, sensitivity was similar (89% vs 87%); RR, 1.00; 95% CI, 0.97-1.03). The NPV (64% vs 93%; RR, 0.71; 95% CI, 0.64-0.79) and accuracy (81% vs 86%; RR, 0.95; 95% CI, 0.91-0.99) were significantly lower in the proximal than distal colon, whereas PPV was higher in the proximal colon (87% vs 76%; RR, 1.11; 95% CI, 1.06-1.17). CONCLUSION: The diagnostic performance of CADx for polyps in the proximal colon is inadequate, exhibiting significantly lower specificity compared with its performance for distal polyps. Although current CADx systems are suitable for use in the distal colon, they should not be employed for proximal polyps until more performant systems are developed specifically for these lesions.
引用
- Rizkala T, Hassan C, Mori Y, et al. Accuracy of Computer-aided Diagnosis in Colonoscopy Varies According to Polyp Location: A Systematic Review and Meta-analysis. Clin Gastroenterol Hepatol. 2024. PMID: 39209199. doi:10.1016/j.cgh.2024.08.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。