文献速递肝病

瞬时弹性成像对慢性丁型肝炎患者晚期纤维化和肝硬化的高诊断价值

High Diagnostic Value of Transient Elastography for Advanced Fibrosis and Cirrhosis in Patients With Chronic Hepatitis Delta.
PubMed 文献 · Clin Gastroenterol Hepatol · 2024-08-30

本研究回顾性纳入230例HDV RNA阳性且接受肝活检和Fibroscan肝硬度测量的慢性丁型肝炎患者,比较瞬时弹性成像(TE)与APRI、FIB-4、Delta-4等无创指标的诊断性能。TE诊断肝硬化(AUC 0.88)和晚期纤维化(AUC 0.86)均显著优于其他无创检测。以>12 kPa诊断肝硬化、10.4 kPa诊断F3,并给出6-10 kPa之间应讨论肝活检的临床路径。

要点

  • TE诊断肝硬化AUC 0.88、晚期纤维化AUC 0.86,均显著优于其他无创检测。
  • LSM>12 kPa诊断肝硬化灵敏度70.5%、特异度86.2%、准确率80.9%。
  • LSM≥10 kPa晚期纤维化可能性高,LSM<6 kPa几乎排除显著纤维化。

核心结论

  • TE对慢性丁型肝炎患者的晚期纤维化和肝硬化具有良好的诊断性能。
  • LSM≥10 kPa时晚期纤维化可能性高,LSM<6 kPa几乎完全排除显著纤维化,6-10 kPa之间应讨论肝活检。

研究设计与样本

  • 回顾性研究,纳入来自多个中心的230例HDV RNA阳性且接受肝活检和Fibroscan肝硬度测量的患者,肝活检与LSM间隔不超过6个月。
  • 采用受试者工作特征曲线下面积和约登指数确定LSM截断值,并与APRI、FIB-4、Delta-4纤维化评分比较。

主要发现

  • 组织学纤维化分期分布为F0-F1占20.4%、F2占27.0%、F3占18.7%、F4占33.9%。
  • TE诊断肝硬化的AUC为0.88,诊断晚期纤维化的AUC为0.86,均显著高于其他无创检测(P=.004和P<.001)。
  • 以>12 kPa为肝硬化截断值,灵敏度70.5%、特异度86.2%、阳性预测值72.4%、阴性预测值85.1%、准确率80.9%。
  • 以10.4 kPa为F3截断值,灵敏度70.2%、特异度83.5%、阳性预测值82.5%、阴性预测值71.7%、准确率76.5%。
  • LSM≤6.2 kPa的患者中89%肝活检仅显示无或轻微纤维化。

关键数值与推荐

  • 肝硬化截断值>12 kPa,灵敏度70.5%、特异度86.2%、阳性预测值72.4%、阴性预测值85.1%、准确率80.9%。
  • F3截断值10.4 kPa,灵敏度70.2%、特异度83.5%、阳性预测值82.5%、阴性预测值71.7%、准确率76.5%。
  • TE诊断肝硬化AUC 0.88、诊断晚期纤维化AUC 0.86,均显著高于其他无创检测(P=.004和P<.001)。

临床怎么用

  • LSM≥10 kPa提示晚期纤维化可能性高。
  • LSM<6 kPa几乎完全排除显著纤维化。
  • LSM在6-10 kPa之间时应讨论肝活检。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND & AIMS: Liver biopsy remains the gold standard for fibrosis staging in patients with chronic hepatitis delta (CHD). Here, we comparatively evaluated the performance of transient elastography (TE) and biomarkers for the diagnosis of liver fibrosis in patients with CHD. METHODS: A total of 230 HDV-infected RNA-positive patients from various centers who underwent liver biopsy and liver stiffness measurements (LSMs) using Fibroscan, within a period of 6 months maximum, were investigated retrospectively. Area under the receiver operating characteristic curve and Youden index were used to establish cutoff values of LSM. TE was compared with other noninvasive tests: aspartate aminotransferase to platelet ratio index, Fibrosis-4, and Delta-4 fibrosis scores. RESULTS: Histologic fibrosis stage distribution was: 20.4% for F0-F1; 27.0% for F2; 18.7% for F3; and 33.9% for F4. TE demonstrated good diagnostic performance for detecting cirrhosis and advanced fibrosis with an Area under the receiver operating characteristic curve of 0.88 and 0.86, which were significantly higher than those obtained with the other noninvasive tests (P = .004 and P < .001). With a cutoff value of >12 kPa for cirrhosis, the sensitivity was 70.5%, specificity was 86.2%, positive predictive value was 72.4%, negative predictive value was 85.1%, and accuracy was 80.9%. Using 10.4 kPa as the cutoff value for F3, the sensitivity was 70.2%, specificity was 83.5%, positive predictive value was 82.5%, negative predictive value was 71.7%, and accuracy was 76.5%. In 89% of patients with LSM ≤6.2 kPa, liver biopsy disclosed only absent or minimal fibrosis. CONCLUSION: TE demonstrated good diagnostic performance for advanced fibrosis and cirrhosis in patients with CHD. Advanced fibrosis is highly probable for LSM values ≥10 kPa. LSM values <6 kPa almost totally exclude significant fibrosis. Between 6 and 10 kPa, liver biopsy should be discussed.

来源:Clin Gastroenterol Hepatol,查看原文。版权归原作者所有。

引用

  1. Roulot D, Brichler S, Layese R, et al. High Diagnostic Value of Transient Elastography for Advanced Fibrosis and Cirrhosis in Patients With Chronic Hepatitis Delta. Clin Gastroenterol Hepatol. 2024. PMID: 39209196. doi:10.1016/j.cgh.2024.08.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。